DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FKC...5 DATA SHEET The FCX–AIII differential pressure (fl ow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FEATURES 1. High accuracy up to ±0.04% 0.065% accuracy as standard, 0.04% accuracy as option. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol FCX–AIII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–AIII. 4. Application flexibility Various options that render the FCX–AIII suitable for almost any process applications include. – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials 5. Programmable output Linearization Function In addition to Linear and Square Root, output signal can be freely programmable. (Up to 14 compensated points at approximation.) 6. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. [ L-Type ] [ T-Type ] SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Static pressure, span, and range limit: Type F KC 11 FKC 22 FKC 33 FKC 35 FKC 36 FKC 38 FKC 43 FKC 45 FKC 46 FKC 48 FKC 49 Span limit [kPa] {m bar} Static pressure [MPa] {bar} −0.1 to + 0.2 {−1 to + 2} −0.1 to + 10 {−1 to + 100 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 16 {−1 to + 160 } −0.1 to + 42 {−1 to + 420 } −0.1 to + 42 {−1 to + 420 } −0.1 to + 42 {−1 to + 420 } −0.1 to + 30 {−1 to + 300 } −0.1 to + 30 {−1 to + 300 } Max. Min. 0.1 1 0.1 { 1 0.32 { 3.2 1.3 { 13 5 { 50 30 { 300 0.32 { 3.2 1.3 { 13 5 { 50 30 { 300 500 {5000 { } } } } } } } } } } } 1 10 } 6 { 60 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } 20000 {200000 } { Range limit [kPa] {m bar} +/− 1 { +/− 10 } +/− 6 { +/− 60 } +/− 32 { +/− 320 } +/− 130 { +/− 1300 } +/− 500 { +/− 5000 } +/− 3000 { +/− 30000 } +/− 32 { +/− 320 } +/− 130 { +/− 1300 } +/− 500 { +/− 5000 } +/− 3000 { +/− 30000 } {+20000,−10000} { +200000,−100000} Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower limit of static pressure (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at temperature below 60°C – The maximum span of each sensor can be converted to different units using factors as below. 1MPa =103KPa=10bar=10.19716kgf/cm2 =145.0377psi 1kpa=10mbar=101.9716mmH2O=4.01463inH2O EDSX6-134h Date Aug. 10, 2011 FKC...5 Over range limit: To maximum static pressure limit Output signal: 4 to 20mA DC (linear or square root) with digital signal superimposed on the 4 to 20mA signal Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Load limitations: see figure below [Ω] Load resistance 2000 1474Ω 1500 R= E-10.5 (Imax+0.9)x10-3 1000 577Ω Operating area 500 24V 250 0 10 45V 16.35 10.5V Power voltage (DC) 50 E[ V ] Note: For communication with HHC(1) (Model: FXW), min. of 250 Ω required. Hazardous locations: (Under an application) SEE TABLE2 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw. Damping: Adjustable from HHC or local configurator unit with LCD display. The time constant is adjustable between 0.06 to 32 seconds. Zero elevation/suppression: −100% to +100% of URL Normal/reverse action: Selectable from HHC(1) Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.0mA to 22.5mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 4.0mA from HHC(1) 3.2 4 20 22.5 [mA] Over scale Burnout Normal operating range Under scale Probable under range Burnout Probable over range Temperature limit: Ambient: −40 to +85°C (−20 to +80°C for LCD indicator) (−40 to +60°C for arrester option) (−10 to +60°C for fluorinated oil filled transmitters) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. Process: −40 to +120°C for silicone fill sensor −20 to +80°C for fluorinated oil fill sensor Storage: −40 to +90°C Humidity limit: 0 to 100% RH Communication: With HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following items can be remotely displayed or configured. Note: HHC’s version must be higher than 7.0 (or FXW 1− 4), for FCX–AIII. Local configurator with LCD display (option): Local confi gurator with 3 push button and LCD display can support following items. Items By communication By local configurator with FXW (with 3 push button) Display Set Display Set Tag No. v v v v Model No. v v v v Serial No. & Software Version v — v — Engineering unit v v v v Range limit v — v — Measuring range v v v v Damping v v v v Linear v v v v Square root v v v v Burnout direction v v v v Calibration v v v v Output adjust — v — v Output mode Data v — v — Self diagnoses v — v — Printer (In case of FXW with printer option) v — — — External switch lock v v v v Transmitter display v v v v Linearize v v — — Rerange v v v v Saturate current v v v v Write protect v v v v History – Calibration history – Ambient temperature history v v v — v v v — Programmable output linearization function: Output signal can be characterized with “14 points linear approximation function” from HHC(1). EMC Conformity: EN61326-1: 2006 Output limits conforming to NAMUR NE43 by order. Loop-check output: Transmitter can be configured to provide constant signal 3.2mA through 22.5mA by HHC(1). (Note) (1) HHC: Hand Held Communicator 2 Performance specifications for linear output Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Accuracy rating: (including linearity, hysteresis, and repeatability) Max span 32kPa to 3000kPa model: For spans greater than 1/10 of URL: ±0.065% of span or ±0.04% of span (21th digit: H) For spans below 1/10 of URL: 0.1 × URL ± 0.015+0.05 % of span Span Max span 20MPa model: For spans greater than 5Mpa: ±0.1% of span For spans below 5MPa: 5MPa ± 0.05+0.05 % of span Span Max span 1kPa, 6kPa model: For spans greater than 1/10 of URL: ±0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ±0.1% of upper range limit (URL) for 10 years for 6th digit code 3, 5, 6, 8 and 9. Temperature effect: Effects per 28°C change between the limits of −40°C and +85°C ( ) ( ) Range code (6th digit in Code symbols) Zero shift “1”/1kPa {10mbar} “2”/6kPa {60mbar} ± 0.125+0.1 URL % Span “3”/32kPa {320mbar} “5”/130kPa {1300mbar} “6”/500kPa {5000mbar} “8”/3000 kPa {30000mbar} “9”/20000kPa {200000mbar} Total effect 50 to 100% 20 to 50% 10 to 20% ( ) ( over 0.1 × URL below 0.1 × URL ±0.065 % ±0.163 % ±0.325 % ±(0.015+0.05 × 0.1 × URL/Span)% ±2.5 × (0.015+0.05 × 0.1 × URL/Span)% ±5 × (0.015+0.05 × 0.1 × URL/Span)% Max span 1kPa, 6kPa model: Output Accuracy 50 to 100% 20 to 50% 10 to 20% ±0.1 % ±0.25% ±0.5 % Temperature effect: Effects per 28°C change between the lim-its of −40°C and +85°C Range code “1” and “2” “3” through “9” Shift at 20% output point URL %/28°C Span URL ± 0.24+0.03125 %/28°C Span ( ± 0.375+0.25 ( ) ) Low flow cut-off: Customer configurable for any point between 0 to 20% of output Supply voltage effect: Less than 0.005% of calibrated span per 1V Update rate: 60 msec Step response: (without electrical damping) ± 0.15+0.1 URL % Span ) ) ) Range code (6th digit in code symbols) “1” Time constant (at 23°C) Dead time 0.33 s “2” 0.3 s “3” 0.12 s “5” through “8” 0.08 s 0.12 s Static pressure effect: Static pressure code (5th digit in Code symbols) Zero shift (% of URL) “1” / 1kPa {10m bar} sensor “2” / 6kPa {60 m bar} sensor ±0.2% / 0.2MPa {2bar} ±0.2% / 3.2MPa {32bar} “2” “3” “4” Span Output Performance specifications common for both atpt modes URL URL ± 0.075+0.0125 Span % ± 0.095+0.0125 Span % ( Accuracy rating: ) ( ( Performance specifications for square root output ±0.035% / 6.9MPa {69bar} ±0.2% / 6.9Mpa {69bar} FKC49 Overrange effect: Static pressure code (5th digit in Code symbols) Zero shift (% of URL) “1” / 1kPa {10m bar} sensor “2” / 6kPa {60m bar} sensor “2” “3” “3” “4” “4” ±0.3% / 0.2MPa {2bar} ±0.1% / 3.2MPa {32bar} ±0.1% / 10MPa {100bar} ±0.1% / 16MPa {160bar} FKC3 5,6,8 ±0.15% / 16MPa {160bar} FKC33 ±0.25% / 42MPa {420 bar} FKC4 3,5,6,8 ±0.2% / 10MPa {100bar} FKC49 Mounting position effect: Zero shift, less than 0.12kPa {1.2m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Internal resistance for external field indicator: 12Ω or less 3 FKC...5 Optional features Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. Process connections: 1/4-18 NPT or Rc1/4 on 54mm centers, as specified. Meets DIN 19213. Process-wetted parts material: l e t e symbols) a i r e t aM d o c Process i g i d h tcover 7( d oC n i V 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1) 316 stainless steel(*1) W H J M T 316 stainless steel(*1) 316 stainless steel(*1) Diaphragm Wetted sensor body 316L stainless 316 stainless steel steel Hastelloy-C 316 stainless steel Hastelloy-C Hastelloy-C lining 316L stainless 316 stainless steel steel +Au coating Monel Monel lining Tantalum Tantalum lining Vent/drain 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Notes: * (1) ASTM CF8M Remark: Availability of above material design depends on ranges and static pressure. Refer to “Code symbols”. Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with polyester coating (standard), or 316 stainless steel (SCS14 per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), 304 or 316 stainless steel (for static pressure code “1”, “2”, and “3” only), or 630 stainless steel (for static pressure code “3” and “4” only). Static pressure rating for code “3” with 304 and 316 stainless steel bolts is degraded to 10MPa. Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 or 316 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm(JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass{weight}: Transmitter approximately 3.1 to 3.6kg without options. Add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option Indicator: A plug-in analog indicator (2.5% accuracy). An optional 5-digit LCD meter with engineering unit is also available. Local configurator with LCD display: An optional 5 digits LCD meter with 3 push buttons can support items as using communication with FXW. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Static pressure rating for code “3” (16 MPa) is degraded to 10MPa. Vacuum service: Special silicone oil and filling procedure are applied. See Fig. 1. Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/ polyurethane double coating. Specify if environment is extremely corrosive. Silicone oil (Code:Y,G,N) Silicone oil (Code:R) [kPa abs] {mbar abs} 101 {1010} Operating pressure Physical specifications Operating area 20 {200} 4 {40} 2.7 {27} None-operating area −40 −15 60 85 120 Process temperature [°C] Fig. 1 Relation between process temperature and operating pressure 4 CODE SYMBOLS 1 2 3 4 5 6 7 8 Digit 4 Description <Connection> Conduit Oval flange Process Case type connection connection screw 7/16-20UNF T type G1/2 Rc1/4 7/16-20UNF 1/2-14NPT 1/4-18NPT T type 1/4-18NPT T type M10 (or M12)(*1) Pg 13.5 1/4-18NPT T type M10 (or M12)(*1) M20×1.5 7/16-20UNF 1/4-18NPT T type Pg 13.5 7/16-20UNF L type G1/2 Rc1/4 7/16-20UNF 1/2-14NPT 1/4-18NPT L type 1/4-18NPT L type M10 (or M12)(*1) Pg 13.5 1/4-18NPT L type M10 (or M12)(*1) M20×1.5 7/16-20UNF 1/4-18NPT L type Pg 13.5 5, 6, 7 <Span and materials> Static Span limit (*2) Process Diaphragm Wetted pressure cover cell body [MPa] [kPa] {bar} (m bar) –0.1 to 316 stainless steel 316L stainless steel 316 stainless steel 0.1…1 +0.2 SUS316 316 stainless steel Hast. C {1…10} {–1 to+2} 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C –0.1 to+10 0.1…6 316 stainless steel 316L stainless steel 316 stainless steel {–1 to 100} {1…60} SUS316 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C –0.1 to+16 0.32…32 316 stainless steel 316L stainless steel 316 stainless steel {–1 to+160} {3.2…320} SUS316 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum 1.3…130 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {13…1300} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum 5…500 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {50…5000} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum 30…3000 316 stainless steel 316L stainless steel 316 stainless steel {300…30000} 316 stainless steel 316L stainless steel 316 stainless steel +Au coating –0.1 to+42 0.32…32 316 stainless steel 316L stainless steel 316 stainless steel {–1 to+420} {3.2…320} SUS316 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel 1.3…130 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {13…1300} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel 5…500 316 stainless steel 316L stainless steel 316 stainless steel SUS316 {50…5000} 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel +Au coating Hast. C lining 316 stainless steel Hast. C Monel lining 316 stainless steel Monel –0.1 to+30 30…3000 316 stainless steel 316L stainless steel 316 stainless steel {–1 to+300} {300…30000} 316 stainless steel 316L stainless steel 316 stainless steel +Au coating 500…20000 316 stainless steel 316L stainless steel 316 stainless steel {5000…200000} Note Note 1 Note 1 Note 1 Note 1 F KC 5 9 10 11 12 13 14 15 21 Digit No. of code 5 6 7 8 9 S T V W X Note 2 11V 11W 11J 11H 22V 22W 22J 22H 33V 33W 33J 33H 33M 33T 35V 35W 35J 35H 35M 35T 36V 36W 36J 36H 36M 36T 38V 38J 43V 43W 43J 43H 43M 45V 45W 45J 45H 45M 46V 46W 46J 46H 46M 48V 48J 49V Note 1: (*1) The thread is M12, if 42MPa {420bar} static pressure is specified. Note 2: (*2) 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. 5 FKC...5 1 2 3 4 5 6 7 8 Digit 9 10 11 12 13 14 Description <Indicator and arrester> Indicator Arrester None None Analog, 0 to 100% linear scale None Analog, 0 to 100% sq. root scale (*3) None Analog, custom scale None Analog, double scale (Linear and sq. root) None None Yes Analog, 0 to 100% linear scale Yes Analog, 0 to 100% sq. root scale (*3) Yes Analog, custom scale Yes Analog, double scale (Linear and sq. root) Yes Digital, 0 to 100% linear scale None Digital, custom scale None Digital 0 to 100% square root scale None Digital, 0 to 100% linear scale Yes Digital, custom scale Yes Digital 0 to 100% square root scale Yes Digital, 0 to 100% linear scale (Local configurator unit with LCD display) None Digital, custom scale (Local configurator unit with LCD display) None Digital, 0 to 100% square root scale (Local configurator unit with LCD display) None Digital, 0 to 100% linear scale (Local configurator unit with LCD display) Yes Digital, custom scale (Local configurator unit with LCD display) Yes Digital, 0 to 100% square root scale (Local configurator unit with LCD display) Yes <Approvals for hazardous locations> None (for ordinary locations) TIIS, Flameproof (Cable gland seal) (*12) TIIS, Intrinsic safety FM, Flameproof (or explosionproof) (*15) FM, Intrinsic safety and nonincentive FM Combined of flameproof and intrinsic safety (*15) ATEX Flameproof (*14) ATEX Intrinsic safety ATEX Type n ATEX Combined of flameproof and intrinsic safety (*14) IECEx Scheme, Flameproof (*14) IECEx Scheme, Intrinsic safety CSA, Flameproof (or explosionproof) (*15) CSA, Intrinsic safety and nonincentive NEPSI, Flameproof (or exprosionproof) NEPSI, Intrinsic safety NEPSI, Combined of flameproof and intrinsic safety <Vent/ drain and mounting bracket> Vent/drain Mounting bracket Process connection Standard None Standard Specify “A”, or “C” or “K” Standard Yes, SUS304 for the 7th digit code Standard Standard Yes, SUS316 “B”, “L”, or “U” Standard Side None Standard Side Yes, SUS304 Standard Side Yes, SUS316 Standard <Options> Extra SS tag plate Stainless steel elec, housing Coating of cell None None None Yes None None None None Yes (*4) Yes None Yes None Yes Yes (*11) Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code “V”, “W”, “J” only) Chlorine service Fluorinated oil (7th digit code “H”, “T”) NACE specification Silicone oil (Not available for 7th digit code “T” and 15th digit code “A”, “B”) Vacuum service Silicone oil for vacuum use <Sensor O-ring / Gasket> Teflon (gasket) Note Note 3 Note 3 F KC 9 10 11 12 13 14 15 21 5 A B C D J E F G H K L P M Q S N 1 2 3 4 5 6 Note 12 Note 15 Note 15 Note 14 Note 14 Note 14 Note 15 A C G D H V X K P M R T E J F S U A C K D F L Note 4 Note 11 Note 11 Y B M N P Q Y W G A D N R B Note 3: (*3) In case of square root output mode, square root scale is not available. Note 4: (*4) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. 6 Digit No. of code 1 2 3 4 5 6 7 8 Digit 15 21 Description Note Note 8 F KC <Bolt/nut> (*8) Vent Drain plug type Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Standard Cr-Mo alloy hexagon bolt/nut Standard Note 5 NACE bolt/nut (ASTM A193 B7M/A194 2HM) (*5) Standard NACE bolt/nut (ASTM A320 L7M/A194 2HM) Standard Note 6 304 stainless steel bolt/304 stainless steel nut (*6) Standard Note 7 630 stainless steel bolt/304 stainless steel nut (*7) Standard Note 6 316 stainless steel bolt/316 stainless steel nut (*6) Standard Note 9 <Other options> (*9) Note 10 High accuracy type (*10) Instruction manual attached Opposite Vent/Drain Plug Position Instruction manual attached Instruction manual unattached Opposite Vent/Drain Plug Position Instruction manual unattached Note 5: (*5) Note 6: (*6) Note 7: (*7) Note 8: (*8) Note 9: (*9) Note 10: Note 11: Note 12: Note 14: Note 15: (*10) (*11) (*12) (*14) (*15) 9 10 11 12 13 14 15 21 5 Digit No. of code A B C D E F U H C L P Static pressure should be −0.1 to +10MPa {−1 to +100bar}. Available for 5th digit code “1”, “2”, “3”. In case of stainless steel bolt with 5th digit code “3”, static pressure should be −0.1 to +10MPa {−1 to + 100bar}. Available for 5th digit code “3”, “4”. In case of tropical use, select stainless bolts and nuts. If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. Available for 5th digit code “3”, “4” and 6th digit code “3” to “8”. Not available for 10th digit code ”C”. Available for 4th digit code "S". Available for 4th digit code "6", "8", "T", "W". Available for 4th digit code "6", "T". 7 FKC...5 ACCESSORIES ORDERING INFORMATION Oval flanges: When ordering this instrument, specify: 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale / Underscale Unless otherwise specified, output hold function is supplied. 4. Output mode (linear or square root output) Unless otherwise specified, output mode is linear. 5. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit). 6. Tag No. (up to 14 alphanumerical characters), if required. (Model FFP, refer to Data Sheet No. EDS6-128) Converts process connection to 1/2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Equalizing valves: (Model FFN, refer to Data Sheet No. EDS6-128) Available in Carbon steel or in 316 stainless steel and in pressure rating 16MPa or 42MPa. Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47) 8 OUTLINE DIAGRAM (Unit:mm) <AMP. case: L type> VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE2) IN CASE OF 4TH DIGIT CODE "S,V,W,X" IN CASE OF 4TH DIGIT CODE "T" "A" PRESS. CONN. 8 RO 38 "B" CONDUIT CONN. 57 37 (21) 4 HOLES 9 DIA. 195 WITH ANALOG IND. (11) 126 43 41 (198) U-BOLT M8 φ81 120 126 41 ZERO 103 70 φ81 41 10 ZERO ADJ. SCREW 103 MTG. PIPE JIS 50A (2B) VENT/DRAIN PLUG WITH DIGITAL IND. NOTE3) 2.5 φ18.5 SIDE VENT(OPTION) 41.3 φ15 E F 8 H OVAL FLANGE SCREW SEE TABLE1 DETAIL "B" (CONDUIT CONN.) 221 (224) NOTE3) DETAIL "A" (PRESS. CONN.) EARTH TERMINAL 10 L.P D SEE TABLE1 H.P 4-M8×12 SEE TABLE1 Conduit conn. Press. conn. 4th digit of the code symbols D E F H S G 1/2 18 2 Rc1/4 7/16-20UNF SCREW DEPTH15 T 1/2-14NPT 16 4 1/4-18NPT 7/16-20UNF SCREW DEPTH15 V Pg13.5 10.5 4.5 1/4-18NPT M10 SCREW DEPTH15 W M20×1.5 16 4 1/4-18NPT M10 SCREW DEPTH15 X Pg13.5 10.5 4.5 1/4-18NPT 7/16-20UNF SCREW DEPTH15 54 70 104 Oval frange screw TABLE 1 OPTION PARTS FOR FLAMEPROOF OF TIIS (JAPAN) 10th digit code C (Cable gland type) NOTE1) 17 19 106 20 DETAIL C φ13 −/CK− CK+ 75 + G1/2 φ33.5 CONNECTION DIAGRAM <SS TAG PLATE> "C" CONDUIT CONN. G1/2 CABLE GLAND NOTE1) IN CASE OF 10TH CODE“C” , φ11 CABLE IS SUITBLE. NOTE2) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). NOTE3) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T" 9 FKC...5 <AMP. case: T type> VENT/DRAIN PLUG (WHEN THE VENT/DRAIN PLUG ATTACHED ON THE UPPER SIDE OF THE DETECTOR) NOTE2) WITH ANALOG IND. IN CASE OF 4TH DIGIT CODE "6" WITH DIGITAL IND. EARTH TERMINAL 41 "A" PRESS. CONN. (21) (11) 8 MTG. PIPE JIS 50A (2B) 10 IN CASE OF 4TH DIGIT CODE "5,7,8,9" ZERO ADJ. SCREW U-BOLT M8 φ81 127 70 100 ZERO 38 57 "B" CONDUIT CONN. 37 191 17 (194) 127 4 HOLES 9 DIA. 20 VENT/DRAIN PLUG DETAIL "A" (PRESS. CONN.) NOTE3) DETAIL "B" (CONDUIT CONN.) φ18.5 OVAL FLANGE SCREW SEE TABLE1 2.5 E F 41.3 8 SIDE VENT(OPTION) 10 SEE TABLE1 4th digit of the code symbols L.P D SEE TABLE1 Conduit conn. Press. conn. NOTE3) φ15 248(251) H H.P 4-M8×12 Oval frange screw D E F H 5 G 1/2 18 2 Rc1/4 7/16-20UNF SCREW DEPTH15 6 1/2-14NPT 16 4 1/4-18NPT 7/16-20UNF SCREW DEPTH15 7 Pg13.5 10.5 4.5 1/4-18NPT M10 SCREW DEPTH15 8 M20×1.5 16 4 1/4-18NPT M10 SCREW DEPTH15 9 Pg13.5 10.5 4.5 1/4-18NPT 7/16-20UNF SCREW DEPTH15 54 70 104 TABLE 1 CONNECTION DIAGRAM −/CK− CK+ 75 + <SS TAG PLATE> 20 10 NOTE2) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR, WHEN THE VENT/DRAIN PLUG IS ATTACHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE 21ST DIGIT OF THE CODE SYMBOLS : C,P). NOTE3) WHEN THE 7TH DIGIT OF THE CODE SYMBOLS "H,M,T" TABLE 2 Authorities ATEX Intrinsic safety Authorities Ex II 1 G Ex ia IIC T5 Tamb = –40°C to +50°C Ex ia IIC T4 Tamb = –40°C to +70°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) Factory Mutual 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb Factory Mutual Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F, G T6 Type 4X Tamb max = +60°C CSA Class I Div.1 Groups C, D Class II Div.1 Groups E, F, G Class III Div.1 Note) “Seal Not Required” enclosure is allowed. Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F, G Class III Div.1 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Imax=94.3mA, Ci=25nF (Without Arrester), Ci=36nF (With Arrester), Li=0.6mH (Without analog meter), Li=0.7mH (With analog meter) TIIS Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=38.4nF, Li=0.694mH IECEx Scheme Ex ia IIC T4 Tamb = –40°C to +70°C Ex ia IIC T5 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator), Ci=36nF (With Arrester), Li=0.7mH (With analog indicator) NEPSI Ex II 2 GD Ex d IIC T6 IP66/67 T85°C Tamb = −40°C to +65°C Ex d IIC T5 IP66/67 T100°C Tamb = −40°C to +85°C −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C Entity Parameters: Vmax=28V, Imax=94.3mA, Pi=0.66W, Ci=35.98nF, Li=0.694mH CSA ATEX Class I II III Div.1 Groups A, B, C, D, E, F, G T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P,M,1,2,3 Q,S,N,4,5,6 E,F,G,H,K − TIIS Ex do IIB+H2 T4 Tamb max = +60°C Maximum process temp. = +120°C IECEx Scheme Ex d IIC T5 IP66/67 Tamb = −40°C to +85°C Ex d IIC T6 IP66/67 Tamb = −40°C to +65°C NEPSI Ex d IIB+H2 T6 Tamb = −40°C to +60°C 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D ATEX Ex II 3 GD EEx nL IIC T5 Tamb = −40°C to +50°C EEx nL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=25.18nF, Li=0.694mH Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=35.98nF, Li=0.694mH EEx nAL IIC T5 Tamb = −40°C to +50°C EEx nAL IIC T4 Tamb = −40°C to +70°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C Type n Nonincendive Authorities Ex ia IIC T4 Ex d IIB+H2 T6 / Ex ia IIC T4 Model code 9th digit A,B,C,D,J L,P,M,1,2,3 Q,S,N,4,5,6 E,F,G,H,K − Flameproof Factory Mutual (pending) Class I II III Div.2 Groups A, B, C, D, F, G T4 Entity Type 4X Model code 9th digit A,B,C,D,J L,P,M,1,2,3 Q,S,N,4,5,6 E,F,G,H,K − Entity Parameters: Ui=42.4V, Ii=113mA, Pi=1W, Ci=35.98nF, Li=0.694mH CSA 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb −40°C to +85°C −20°C to +80°C −20°C to +60°C −40°C to +60°C −10°C to +60°C Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F, G Class III Div.2 Temp Code T5 Tamb max = +50°C Temp Code T4 Tamb max = +70°C Entity Parameters: Vmax=28V, Ci=25.18nF (Without Arrester), Ci=35.98nF (With Arrester), Li=0.694mH 11 FKC...5 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan