FUJI EDSX6-139H

PORTABLE TYPE
ULTRASONIC FLOWMETER (PORTAFLOW-C)
DATA SHEET
FSC, FSD
PORTAFLOW-C is a portable type ultrasonic flowmeter
utilizing the transit time measuring method, using a clampon type detector.
It is a compact and lightweight instrument incorporating the
latest electronics and digital signal processing technologies,
realizing high performance and easy operation.
FEATURES
1. Compact and lightweight
The adoption of the latest electronics and digital
signal processing technologies has reduced the size
and weight of the flow transmitter by 30% and 30%,
respectively, in comparison with the Fuji conventional
portable flowmeter (Model FSC). (in comparison to
our existing model)
2. Battery operation
The flowmeter is designed for 12 hours of continuous operation via built-in battery which is rechargeable in 3 hours with the exclusive power adapter.
3. Full variety of detectors
The flowmeter is suitable for various types of detectors applicable for small to large diameter pipe (pipe
inner diameter φ13 to φ6000mm) and low to high
temperature (−40 to +200°C).
4. High accuracy and high-speed response
The flowmeter is designed for high accuracy
(±1.0%).
Response time is within 1 second.
5. Improved anti-bubble characteristic
Anti-bubble characteristic is greatly improved by
digital signal processing.
6. Excellent performance and easy operation
Large graphic LCD that is outside but easy to read.
Minimum number of function keys are used for page
selection, allowing easy setting.
While battery is working, the flowmeter is water
resistant and tolerates exposure to rain.
7. Large capacity storage by SD memory card
Measured data is periodically stored in SD memory
card. For example, in the case of 256MB (option), it
can be saved about 1 year measurement date(In case
of saving period 30 seconds, 14 kinds of saved data).
Available up to 8MB.
8. Serial communication
Use of a USB port allows easy connection to a personal computer. Measured date collection panel and
Loader software for PC (standard) which is available
for display and change of parameter (site setting) are
prepared.
9. Heat quantity (calorie) measurement
Heat quantity (calorie) may be measured by temperature input, making energy management easy for
cooling and heating.
Flow transmitter (FSC)
Detector for transit time(FSD)
Detector for high-temperature(FSD)
10.Graphic printer connection (option)
Easy recording with the Integral type printer.
11.Flow velocity profile measurement (option)
Flow profile may be observed in real time.
SPECIFICATIONS
Measuring objects
Measurement fluid:
Uniform liquid in which ultrasonic
waves can propagate.
Turbidity of fluid:10000 mg/L or less
State of fluid:
Well-developed turbulent or laminar
flow in a filled pipe.
Fluid temperature:−40 to +200°C
Measuring range:0···±0.3 to ±32m/s
Piping conditions
Applicable piping material:
Select from carbon steel, stainless
steel, cast iron, PVC, FRP, copper,
aluminum, acrylic or material of known
sound velocity.
Pipe size:
Flow rate measurement
f13 to f6000mm
Flow velocity profile measurement
f40 to f1000mm
EDSX6-139h
Date
Jul. 22, 2011
FSC, FSD
Lining material: Select from no lining, tar epoxy,
mortar, rubber, Teflon, pyrex glass or
material of known sound velocity.
Note) No gap allowed between the
lining and the pipe.
Straight pipe length:
10D or more upstream and 5D or more
downstream (D: internal pipe diameter)
Refer to Japan Electric Measuring Instruments Manufactures’ Association’s
standard JEMIS-032 for details.
Performance specifications
Accuracy rating:
Pipe inner
diameter
f13 to f50mm
f50 to f300mm
f300 to f6000mm
Flow velocity
range
2 to 32m/s
0 to 2m/s
2 to 32m/s
0 to 2m/s
1 to 32m/s
0 to 1m/s
Accuracy
±1.5% of rate
±0.03m/s
±1.0% of rate
±0.02m/s
±1.0% of rate
±0.01m/s
Note) Reference conditions are based on JEMIS-032.
Flow transmitter (Type: FSC)
Power supply: Built-in battery or AC power adapter
Built-in battery:Exclusive lithium button battery
(5000m Ah)
Continuous operation time, approx. 12
hours (without printer, back light OFF,
output current not used and at normal
ambient temperature (20°C))
Recharging time, approx. 3 hours
(power adapter used)
Recharging temperature range: 0 to
+40°C
Power consumption: Min. 3W and
Max. 16W
The consumption varies depending on
the use conditions.
Power adapter:Exclusive power adapter 90V to 264V
AC (50/60Hz), 70VA or less.
LCD:
Semi-transmissive color graphic display
240 × 320 (with back light)
Measurement value (instantaneous
flow rate, integrated flow rate) and
various settings are displayed.
Excellent visibility even outdoors in
direct sunlight.
LED display:
Status display when using AC power
adapter.
DC IN (green): Power supply status
CHARGE (red): Battery charging underway
Operation keypad:
11 buttons
(ON, OFF, ENT, ESC, MENU, , , ,
, LIGHT, PRINT)
Power failure backup:
Measurement value is backed up by
nonvolatile memory.
Clock backup with lithium battery (effective term, 10 years or more)
Response time: 1 second
2
Analog output signals:
4 to 20mA DC, one point (load resistance, 600Ω or less)
Instantaneous velocity, instantaneous
flow rate or heat quantity (calorie) after
scaling.
Analog input signal:
4 to 20mA DC, one point
(input resistance, 200Ω or
Total
less)
4 to 20mA DC, one point (in- 2 points
put resistance, 200Ω or less)
or 1 to 5V DC, one point
Used to input temperature for heat
quantity measurement, etc.
SD memory card: Used for data logger function and
recording screen data.
Available up to 8GB (Option256MB)
Compliant media
• SD memory card: speed class 2, 4, 6
• SDHC memory card: speed class 4, 6
Format
• FAT16: 64MB to 2GB
• FAT32: 4GB, 8GB
Otherwise, reading and saving are
impossible.
File format
• Date logger: CSV file
• Screen date: Bit map file
Serial communication:
USB port (device* compatible):
Mini B receptacle
Connectable number of Mini B receptacles:
1 unit
Transmission distance: 3m max.
Transmission speed: 500kbps
Data:
Instantaneous velocity, instantaneous flow rate, total value, heat
quantity (calorie) value, error information, logger data, etc.
* Device: Connected plug from PC
Printer (option): To be mounted on top of transmitter
unit
Thermal line dot printing
Note) When the Chinese display is selected,
printing is made in kanji characters.
Ambient temperature:
−10 to +55°C (Without printer)
−10 to +45°C (With printer)
Ambient humidity: 90%RH or less
Type of enclosure: IP64 (Without printer)
Enclosure case: Plastic case
Outer dimensions: H210 × W120 × D65mm (Without printer)
H320 × W120 × D65mm (With printer)
Weight:
1.0kg (Without printer)
1.2kg (With printer)
Various functions
Display language: Selectable from Japanese, English,
German, French, Spanish or Chinese
(switchable by key operation).
Clock display function:
Time (year, month, day, hour, minute)
display (configurable)
Monthly error: about 1 minutes at normal temperature (20°C).
Instantaneous value display function:
Instantaneous velocity, instantaneous
flow rate display (The flow in reverse
direction is displayed with minus “−.”)
Numeric value: 10 digits (decimal point
equals 1 digit)
Unit: Metric/English system selectable
Metric system
Velocity:m/s
Flow rate:L/s, L/min, L/h, L/d, kL/d,
ML/d, m3/s, m3/min, m3/h,
m3/d, km3/d, Mm3/d, BBL/s,
BBL/min, BBL/h, BBL/d,
kBBL/d, MBBL/d
English system
Velocity:ft/s
Flow rate:gal/s, gal/min, gal/h, gal/d,
kgal/d, Mgal/d, ft3/s, ft3/min,
ft3/h, ft3/d, kft3/d, Mft3/d,
BBL/s, BBL/min, BBL/h, BBL/
d, kBBL/d, MBBL/d
Total value display function:
Display of forward or reverse total
(reverse is displayed as minus)
Numeric value: 10 digits (decimal point
is corresponding to 1 digit)
Unit: Metric/English system selectable
Metric system
Flow rate total: mL, L, m3, km3, Mm3,
mBBL, BBL, kBBL
English system
Flow rate total: gal, kgal, ft3, kft3, Mft3,
mBBL, BBL, kBBL, ACRE-ft
Consumed heat quantity (calorie) display function:
Display of consumed heating medium
Metric system
Heat flow: MJ/h, GJ/h
Total heat quantity: MJ, GJ
English system
Heat flow:MJ/h, GJ/h, BTU/h, kBTU/h,
MBTU/h, kWh, MWh
Total heat quantity:
MJ, GJ, BTU, kBTU, MBTU,
kW, MWh
J
: Joule
BTU
: British thermal unit
W
: Watt
Computation function of consumed heat quantity (calorie):
This function calculates the heat
quantity received and sent with liquid
(water) in cooling and heating.
Converter
Temperature
sensor
Consumed heat quantity
q = K · Q · (T1–T2)
K : heat quantity (calorie)
conversion factor
(For heating K = 4.123,
For cooling = 4.186)
T1: Fluid temperature
(inlet)
Heat
exchanger
Heat
source
Converter
Temperature
sensor
T2: Fluid temperature (outlet)
Detector
(type : FSD)
Temperature display function:
Fluid temperature be displayed by current input from temperature transmitter.
Metric system
Temperature unit: °C or K
English system
Temperature unit: F or K
Site data storage function:
Max. 32 locations (sites) data (pipe
size, material, fluid type and etc) can
be stored into built-in non-volantile
memory.
Damping:
0 to 100sec (every 0.1sec) configurable
for analog output and velocity/flow
rate display
Low flow cut: Equivalent to 0 to 5m/s
Output setting function:
Current output scaling, output type,
burnout setting and calibration
Serial communication function:
Instantaneous velocity, instantaneous
flow rate, total value, heat flow, error information, received waveform,
analog input, velocity profile data,
logger data, etc. may be downloaded
to personal computer.
Logger function: Instantaneous velocity, instantaneous
flow rate, total value, heat flow, error
information, received waveform, analog input, velocity profile date can be
saved in a SD memory card.
Waveform display function:
Bi-directional received waveforms may
be displayed.
Graph display function:
Flow rate trend graph may be displayed.
Printing function (option):
Hard copy output of a screen
Periodic printing (type: text, graph)
Logger date (type: text, graph)
Flow velocity profile measurement (option): Flow velocity profile may be observed
in real time using the exclusive detector (option).
(Refer to page 5 for details.)
Detector (Type: FSD)
Type of detector:
Kind
Type
Small diameter
Small type
Middle type
Large type
High temperature
FSD22
FSD12
FSD41
FSD51
FSD32
Internal pipe
diameter (mm)
f13 to f100
f50 to f400
f200 to f1200
f200 to f6000
f50 to f400
Fluid temperature
−40
−40
−40
−40
−40
to
to
to
to
to
100°C
100°C
80°C
80°C
200°C
Mounting method:
Mounting on outside of pipe
Sensor mounting method: V or Z method
Signal cable:
Exclusive coaxial cable
Standard 5m (included with FSD41, 51
and FSD32)
Q: Flow rate of the fluid
3
FSC, FSD
MEASURING PRINCIPLE
Method for connection:
Flow transmitter side
Exclusive connector
Detector side
Large/middle type: Screw terminal
Others: BNC connector
Ambient temperature: −20 to +60°C
Ambient humidity:Large/middle type sensor:
100%RH or less
Others: 90%RH or less
Type of enclosure:
Large/middle type sensor: IP67
Others: IP52
Material and mounting belt/wire:
Kind
Type
Small diamFSD22
eter
Small type
FSD12
Middle type
FSD41
Large type
FSD51
High temperaFSD32
ture
Sensor
case
Mounting
bracket
Aluminum alloy
Plastic
+ Plastic
Aluminum alloy
Plastic
+ Plastic
Plastic SUS304
Plastic −−
Aluminum alloy
SUS304
+ SUS304
With ultrasonic pulses propagated diagonally between the
upstream and downstream sensors, flow rate is measured
by detecting the time difference obtained by the flow of
fluid.
Detector
Upstream sensor
θ
t1
Flow
velocity V
Output
Flow signal
transmitter
D
t2
Downstream sensor
MOUNTING OF DETECTOR
Mounting belt
/wire
Plastic cloth
belt
Plastic cloth
belt
Stainless wire
Stainless wire
Plastic wedge
Pipe
PZT oscillator
Lining
Stainless belt
CONFIGURATION DIAGRAM
Extension cable (option):
Extended when the length of the detector signal cable is not sufficient.
Length: 10m, 50m
(1) When V method is used for mounting
Cable
Flow
transmitter
Detector
4 to 20mA
DC
(2) When Z method is used for mounting
Cable
Flow
transmitter
Detector
4 to 20mA
DC
DETECTOR SELECTION GUIDE
Type (Name)
FSD22
(Small diameter)
FSD12
(Small type)
FSD41
(Middle type)
Fluid
temperature Mounting
method
[°C]
Inner diameter of piping ø (mm)
13 25
50
100
200
250
300
400
1000
3000
6000
*2)
−40 to 100
−40 to 100
V
13
V
Z
100
50
*1)
300
150
V
400
200
600
−40 to 80
Z
FSD51
(Large type)
−40 to 80
FSD32
(High-temperature)
−40 to 200
400
V
200
Z
200
V
Z
50
*1)
1200
3000
6000
250
150
400
*1) When FSD12 or FSD32 is mounted using the Z-size method, guide rail (option) is required additionally.
*2) For the pipe inner diameter of φ13mm, the sensor mounting dimension may be 0.0mm or less depending on pipe material and thickness.
When the sensor mounting dimension is 0.0mm or less,measurement error is about 2 to 5%.
<Description of the table>
It shows pipe thickness of each material that the sensor mounting
size is to be 0.0mm, when fixing a pipe. If the fluid is the one other
than water, and if the sound velocity of fluid is faster than the one
of water, the sensor mounting size is to be 0.0mm or more.
4
Required min. pipe thickness (fluid: water) (Unit: mm)
Steel pipe
2.15 or more
FRP
3.21 or more
Stainless pipe
1.87 or more
Ductile cast iron 2.15 or more
PVC pipe
3.69 or more
PEEK
3.69 or more
Copper pipe
3.82 or more
PVDF
3.69 or more
Cast-iron pipe
2.98 or more
Acrylic pipe
2.90 or more
Aluminum pipe 1.99 or more
Polypropylene
3.69 or more
FLOW VELOCITY PROFILE DISPLAY FUNCTION
(OPTION)
Flow velocity profile can be observed in real time using
the dedicated detector from the outside. It is specifiable
by the code symbol of flow transmitter.
APPLICATION
Measurement principle
<Pulse Doppler method>
• Ultrasonic pulses are transmitted through the fluid flow.
Entrained bubbles and microscopic particles within the
fluid create frequency phase shifts (Doppler effect.) The
resulting doppler shifts are integrated across the inside
pipe diameter cross section. The resulting profile curve
is a real-time dynamic display of the flow profile within
the pipe.
Pulse Doppler method is applicable to observe flow velocity
profile in real time, display the flow status in the pipe, and
decide the appropriate measurement location. Also, it can
be used for diagnosis of flow and laboratory test.
SPECIFICATIONS
Measuring fluid: Uniform liquid in which ultrasonic
waves can propagate.
Turbidity of fluid: Axisymmetric flow in a filled pipe.
Fluid temperature:
−40 to +100°C (FSDP2)
−40 to +80°C (FSDP1,FSDP0)
Air bubble quantity:
0.02 to 15Vol% (Velocity is 1m/s)
Pipe size:
Small type sensor : f40 to f200mm
Middle type sensor :f100 to f400mm
Large type sensor :f200 to f1000mm
Measurement range:
0 to ±0.3: ±Maximum Velocity (depending on the pipe diameter)
Refer to chart, table.1.
Note) This function is to observe flow
velocity profile, and it may be different
from actual flow rate.
DETECTOR FOR FLOW VELOCITY PROFILE
MEASUREMENT (TYPE: FSDP)
Mounting method:
Mounting on outside of existing pipe
Ambient temperature: −20 to +80°C
Ambient humidity: 100% RH or less
Type of enclosure:
IP67 (with waterproof BNC connector
provided.)
Material:
Sensor housing:PBT
Guide frame:
Aluminum alloy
Mounting belt: Plastic cloth belt/stainless belt
Sensor 1 (FSD)
Flow
Air
bubbles
Reflection
Sensor 2
(FSD)
Flow velocity
Flow
velocity
Profile 2
Piping wall
Flow
velocity
Profile 1
Center
Piping wall
The above shows an example when using two sensors.
One detector displays the flow velocity profile for a radius.
Block diagram
(1) Using one sensor
Cable
Power
supply
Sensor (FSD)
Flow
Transmitter
(2) Using two sensors
Cable
Sensor (FSD)
Power
supply
Flow
Transmitter
Sensor (FSD)
5
FSC, FSD
Table.1
Maximum measurement range of Pulsed Doppler method.
When nominal thickness of a stainless pipe of pipe material is Sch20s and the
fluid is water, the maximum measurement range varies depending on the outer
diameter of pipe, nominal thickness, material, or fluid type.
<Maximum measurable flow velocity>
Unit: m/s
Diameter
FSDP2
FSDP1
FSDP0
40A
6.56
50A
6.52
65A
5.31
80A
4.65
90A
4.12
100A
3.69
7.25
125A
6.08
3.08
150A
5.20
2.63
200A
4.05
7.77
2.04
250A
6.38
3.30
300A
5.41
2.78
350A
4.90
2.51
400A
4.31
2.20
450A
3.80
500A
3.48
550A
3.17
600A
2.91
650A
2.71
700A
2.52
750A
2.35
800A
2.21
850A
2.08
900A
1.97
1000A
1.77
<Maximum measurable flow rate>
Unit: m3/h
FSDP2
FSDP1
FSDP0
33.6
52.7
72.1
86.5
102
118
231
289
147
354
179
474
908
239
1168
604
1428
735
1598
820
1858
951
2118
2358
2618
2879
3096
3357
3618
3879
4140
4400
4902
PC Loader software
Equipped as standard
• PC/AT compatible machines. (Operation on custom built
PCs or shop-brand PCs cannot be guaranteed.)
• Major functions:Performs parameter (site setting)
display /change of the main unit and
collects measured date.
Instantaneous velocity, instantaneous flow
rate, total value, error information, received
waveform, analog input, logger data, etc. may
be downloaded in a personal computer.
• O/S: Windows2000/XP/Vista*
• Memory requirement: 128MB or more
• Disk unit: Windows2000/XP/Vista-compatible CD-ROM
drive
• Hard disk drive capacity: Free space of 64MB or more
* Windows Vista: Use it in basic mode.
It is not available for Windows Aero.
CODE SYMBOL
<Flow transmitter>
1 2 3 4 5 6 7 8
F SC
9 10 11
1 -
Description
0
S
1
2
0
1
A
B
C
1
0
1
Y
J
E
C
<Specification>
Standard
<Converter>
Basic system
Basic system + Printer
<Flow velocity profile measurement>
None
Provided (detector to measure flow
velocity profile is separately required.)
<Power adapter>
AC power + power cord (125V AC) for
Japanese and North American use
AC power + power cord (250V AC) for
European and Korean use
AC power + power cord (250V AC) for
Chinese use
Modification No.
<SD memory card>
None
Provided (256MB)
<Bound instruction manual/Language>
None (Factory-set language: English)
Provided/Japanese
(Factory-set language: Japanese)
Provided/English
(Factory-set language: English)
Provided/Chinese
(Factory-set language: Chinese)
(Note1) Instruction manual contained in CD
is the standard attached article.
(Note2) You can change the language by
key operation.
6
OPTIONAL ITEMS
<Detector>
(for transit time)
1 2 3 4 5 6 7 8
Name
Specifications
Arrangement No.
1
Battery
Special type Li-ion battery
(7.4V, 2500mAh)
ZZP∗TK7N6384P1
2
AC power
adapter
Special type power adapter and
90 to 264V AC, 50/60Hz
· Power connector conversion code ZZP∗TK7N6380C4
3
Power code
Japan, North America:125V AC 2m
Europe, Korea: 250V AC 2m
China: 250V AC 2m
ZZP∗TK7N6621P1
ZZP∗TK7N6608P1
ZZP∗TK7N6609P1
4
Printer
To be mounted on top of converter
Thermal serial dot system (8 x 384
dot)
ZZP∗TK4J2634C1
5
Printer roll
paper
Maker: SEIKO I SUPPLY Co. Ltd.
Type: TP-211C-1
Specifications: Thermal roll paper
Width: 58mm×ø48mm
ZZP∗TK7N6381P1
6
Silicone
grease
Maker: Shin-Etsu Chemical Co., Ltd.
Type:
· For standard use
G40M, 100g ZZP∗45231N5
· For high temperature KS62M, 100g ZZP∗TK7P1921C1
7
Signal cable
Special type signal cable, 5m × 2
·FSD12, 22, 32 (Connector on one
side)
· FSD41 (Connector on one side)
· FSD51 (Connector on one side)
Description
F SD
1
2
4
5
3
<Kind>
Small type (for φ50 to φ400mm) *1) *2)
Small diameter (for φ13 to φ100mm)
Middle type (for φ200 to φ1200mm)
Large type (for φ200 to φ6000mm)
High-temperature (for φ50 to φ400mm) *1) *2)
2
2
1
1
2
<Terminal mold>
None
Provided (Middle/Large type only)
0
1
<Structure>
General use
Y
Modification No.
1
Note)
*1) Applicable diameter range:
V method: φ50 to φ250 (FSD32), φ50 to φ300 (FSD12)
Z method: φ150 to φ400 (FSD32, FSD12)
Use the optional guide rail, if a pipe that does not allow ultrasonic
waves to pass through easily, such as when an old pipe, cast iron
pipe or a pipe with mortar lining is used, or the flow or liquid high
in turbidity is measured. Employ the Z method for mounting.
(for flow velocity profile measurement)
1 2 3 4 5 6 7 8
F SD
Description
0 Y 1
<Kind>
Small type (φ40 to φ200mm)
Middle type (φ100 to φ400mm)
Large type (φ200 to φ1000mm)
P2
P1
P0
<Terminal mold>
None
0
<Structure>
General use
Y
Modification No.
1
8
9
BNC adapter · BNC adapter (×2)
Extension
signal cable
ZZP∗TK7N7795C1
ZZP∗TK7N7795C2
ZZP∗TK7N7795C3
ZZP∗TK7N6323P11
Special type coaxial cable with BNC
connector
ZZP∗TK468664C3
· 10m × 2
ZZP∗TK468664C4
· 50m × 2
10 Analog
6-core cable, 1.5m, with connector
input/output
cable
ZZP∗TK4J2639C1
11 Mounting
belt /wire
ZZP∗TK7G7979C1
SCOPE OF DELIVERY
<Flow transmitter : FSC>
Name of unit
1 Basic system
2
Option
Scope of delivery
1) Conversion unit
2) Power adapter and
Power connector conversion cord
3) Power cord
4) Analog input/output cord (1.5m)
5) USB cable (1m)
6) Carrying case
7) Strap
8) Special type signal cable (5m × 2)
9) BNC adapter
10) CD-ROM (Instruction manual and
Loader software for PC)
1) Printer unit + rolled paper (1 roll)
2) SD memory card (256MB)
3) Bound instruction manual (including
a detector)
<Detector : FSD>
Name of unit
Scope of delivery
1 Detector for propa- 1) Sensor unit
gation time differ- 2) Signal cable (5m)
(included with FSD41, 51)
ence (FSD)
3) Mounting belt/wire
4) Silicone grease (100g)
2 Detector for flow 1) Detector unit
v e l o c i t y p r o f i l e 2) Mounting belt/wire
(FSDP)
3) Silicone grease (100g)
12 Guide rail
for hightemperature
sensor
(In mounting
by the Z
method)
· Small type/small diameter sensor:
Plastic cloth belt
· Large type sensor:
Stainless wire
Nominal diameter
f200 to f500mm
f200 to f1000mm
f200 to f2000mm
f200 to f3000mm
f200 to f6000mm
· High-temperature sensor:
Stainless steel belt
ZZP∗TK7G7980C1
ZZP∗TK7G7980C2
ZZP∗TK7G7980C3
ZZP∗TK7G7980C4
ZZP∗TK7G7980C5
ZZP∗TK7P1943C1
ZZP∗TK4J5917C3
· Mounting bracket material:
Aluminum alloy+SUS304
· FSD32
13 Guide rail for · Mounting bracket material:
small type
Aluminum alloy+plastic
detector
· FSD12
(In mounting
by the Z
method)
ZZP∗TK4J5917C1
14 SD memory Maker: Apacer Technology, Inc.
card
Type: AP-ESD256TPSR
Capacity: 256MB
ZZP∗TK7N6386P1
15 USB cable
ZZP∗TK7N6622P1
Maker: Sunwa Supply Inc.
Type: KU-AMB510
Specifications: Mini USB cable
(1.0m)
Note 1) Silicon grease is for filling a gap between a detector and a
pipe joint area. It is provided with a detector.
Since silicon grease does not become hardened, if you use
it in the long term, periodic maintenance is required. (Under
the condition of room temperature, semiannual cleaning
and refill is recommended.)
Note 2) When you order a detector alone, an instruction manual is
not provided. Please request, if necessary.
7
FSC, FSD
Diagram
To connect signal cables for FSD12, FSD22, FSD32, FSDP2, FSDP1, FSDP0
Exclusive use signal cable
Printer
(option)
BNC
connector
Detector
To connect signal cables for FSD41 FSD51
Detector input
(the downstream side)
PORTAFLOW
Flow
transmitter
BNC connector
Detector input
(the upstream side)
ON
OFF
FEED
AO analog output 4 to 20mA DC
AICH1 analog input 4 to 20mA DC or 1 to 5 V DC
AICH2 analog input 4 to 20mA DC
ENT
Print
MENU
CHARGE DC IN
PC
SD
SD memory
card
Power connector
Conversion cord
USB cable
AC90 to 264V
Power cord
AC power adaptor
for use AC adaptor
To connect PC
Conditions on straight pipe
(D: Nominal diameter of pipe)
Type
Length of upstream straight pipe
Length of downstream straight pipe
10D or more
L ≥ 5D
90° bend
L ≥ 10D
10D or more
Detector
Tee
L ≥ 10D
L ≥ 50D
0.5D
or more
10D or more
L ≥ 30D
L ≥ 5D
D
Diffuser
1.5D or more
L ≥ 10D
L ≥ 50D
Contraction pipe
L ≥ 30D
L ≥ 10D
Valve
Flow controlled upstream
Flow controlled downstream
Isolation valve
Check valve
L ≥ 50D
Pump
P
Note) Source: Japan Electric Measuring Instruments Manufacturers' Association (JEMIS-032)
8
Detector
BNC adaptor
Analog input/output cable
ESC
Signal cable
OUTLINE DIAGRAM (Unit:mm)
Flow transmitter
120±1.8
65±1.8
2-M4, Depth5 (both sides)
PORTAFLOW
210±2.5
SENSOR
UPSTREAM
DOWNSTREAM
Sensor (downstream)
ON
OFF
ESC
FEED
DC12V
AI/AO
Sensor (upstream)
Analog input/output
ENT
Print
MENU
DC power input
CHARGE DC IN
Power switch
SD memory card slot
USB port
Weight : Approx. 1.0kg
9
FSC, FSD
OUTLINE DIAGRAM (Unit:mm)
Flow transmitter (with printer)
120±1.8
65±1.8
Printer
Approx. 320±4.5
2-M4, Depth5 (both sides)
PORTAFLOW
SENSOR
UPSTREAM
DOWNSTREAM
Sensor (downstream)
ON
FEED
OFF
DC12V
AI/AO
Sensor (upstream)
ESC
Analog input/output
ENT
DC power input
Print
MENU
CHARGE DC IN
Power switch
SD memory card slot
USB port
Weight : Approx. 1.2kg
10
OUTLINE DIAGRAM (Unit:mm)
Saddle
Saddle
Scale(mm)
Scale (mm)
Spacing: 0 to 133
540±2
Spacing: 0 to 348
Name prate
mm
Scale (inch)
Connector
Connector
Name plate
320±2
Scale(inch)
Lock nut
Element holder
inch
Cursor
Lock nut
Element holder
Cursor
36±0.5
90max.
90max.
36±0.5
52.5±0.5
52.5±0.5
Weight : Approx. 0.8kg
Detector FSD12 (small type)
Scale(inch)
Detector FSD22 (small diameter)
Name plate
Saddle
54±2
Connector
Weight : Approx. 0.6kg
Scale(mm)
(114)
Sensor
Distance between
two sensors 0 to 330
Name plate
A
Wire rope
Mounting spring
Lock nut
(ø19)
46±1
530±2
37±1
Element holder
Cursor
φ26
33±0.5
90max.
205max.
8.5 8
ø4.3
Cable
BNC Connector
+200
5000 −0
CONNECTION DIAGRAM
G +
Weight : Approx. 1.7kg
Weight : Approx. 1.3kg
44±1
TO FLOW TRANSMITTER
Detector FSD32 (high-temperature)
Detector FSD41 (middle type)
11
FSC, FSD
OUTLINE DIAGRAM (Unit:mm)
Name plate
Wire rope
Mounting spring
92±2
BNC connector
Sensor unit
(114)
78±1
Type.
Mfd.
A
67±2
(ø19)
L
Detector
Absorber unit
Ser.No.
BNC Connector
8.5 8
Cable
Made in Japan
ø4.3
+200
5000 −0
Frame
Weight : Approx.2.2kg
Detector FSD51 (large type)
(H)
Clip
(ø12.3)
Straight plug
(ø5)
AO
AI ch1
AI ch2
W±1
+100
1500 -0
100±5
Weight : approx. 0.1kg
Code color
Black (BK)
White (W)
Red (R)
Green (G)
Yellow (Y)
Brown (BN)
Clip color
Red (R)
Black (BK)
Red (R)
Black (BK)
Red (R)
Black (BK)
(+)
(−)
(+)
(−)
(+)
(−)
Type
Diameter (mm)
L
H
W
Weight
Approx. (kg)
FSDP2
φ40 to φ200
260±1.2
70
57
0.8
FSDP1
φ100 to φ400
260±1.2
72
57
0.9
FSDP0
φ200 to φ1000
350±2.0
90
85
2.0
Mark
AO
AI ch1
AI ch2
Analog input/output cable
Detector FSDP (Detector for flow velocity profile measurement)
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/
Information in this catalog is subject to change without notice.
Printed in Japan