FUJI EDSX6-140D

SERIES
ULTRASONIC FLOWMETER <
>
DATA SHEET
FSV, FLS/FSG/FSD
This flowmeter is a clamp-on type ultrasonic flow meter
based on transit-time measuring method.
Making full use of the latest electronics and digital signal
processing technologies, we realized a compact and lightweight design, and improved the accuracy and easiness to
use while keeping with anti-bubble performance.
The communication function (MODBUS: Option) is also
applicable.
FEATURES
1.Compact and light-weight
Thanks to the adoption of the latest electronics the
flow transmitter size and mass are 1/3 of our traditional
instrument.
2.Full variety of sensors
The flowmeter can be used with various types of sensors
applicable for wide range of pipe size (ø13 to ø6000mm)
and fluid temperature (-40 to +200°C).
3.High accuracy
The flowmeter is designed for high accurary (better than
±1.0% of rate) by dynamic correction of fully-developed
flow profile. Reynolds Number is calculated and a meter
factor (K) is automatically applied for best accuracy at
all flow velocities. Further, the adoption of new sound
velocity measurement system permits measurements of
fluids of unknown sound velocity. Moreover, affection
from fluid temperature and pressure is negligible (AutoTemp./Press. compensation).
4.Excellent resistance against aerated flow
Fuji's unique ABM feature improves measurement reliability for different flow like slurries, sludge, raw sewage
and bubble-contained flow (acceptable up to air bubble
of 12% volume at 1m/s velocity).
5.Quick response
With the use of high-speed micro-processor suited
for digital signal processing, the fast response time is
realized.
6.Multi-lingual
The following languages are supported for display:
Japanese (Katakana), English, German French, and
Spanish.
7.Excellent performance and easy operation
LCD and function keys are allowing easy configuration
and trouble shooting.
− LCD with back light
− Easy mounting of sensor
− Trouble shooting
− Easy operation with keypad on the front surface of
the flow transmitter (FSV···S)
Flow transmitter (FSV···S)
Detector
(FLSE12)
(FLSE22)
Detector (FSD22)
Detector (FSD32)
Detector (FSG)
SPECIFICATIONS
Operational specifications
System configuration:
Single-path system of a flow transmitter (Model FSV) and a detector (Model
FLS/FSG/FSD)
Applicable fluid: Homogenous liquid where the ultrasonic signal can be transmitted
Bubble quantity: 0 to 12vol% (for pipe
size 50A, water, velocity 1m/s)
Fluid turbidity: 10000mg/L max.
Type of flow: Fully-developed turbulent
or laminar flow in a full-filled pipe
Flow velocity range:
0 to ±0.3 ... ±32m/s
EDSX6-140d
Date
Apr. 1, 2011
FSV, FLS/FSG/FSD
Common type
Popular type
Detector
Pipe size
Applicable pipe
(inner diameter) material
Mounting Fluid
method temperature
range
(Note 3)
9th digit in
ø25 to ø100 mm Plastic (PVC, etc.) (Note 1)
code symbol
FLSE12
Metal pipe (SS, steel pipe,
Y... -20 to
ø50 to ø100 mm copper pipe, aluminum pipe,
+100°C
etc.) (Note 2)
V method A... 0 to
Plastic (PVC, etc.) (Note 1)
+120°C
Metal pipe (SS, steel pipe,
(Note 4)
FLSE22 ø50 to ø225 mm
copper pipe, aluminum pipe,
Heat shock
etc.) (Note 2)
resistance
150°C,
30min
-40 to 100°C
FSD22 ø13 to ø100 mm
V method
FSGS3 ø50 to ø300 mm
Plastic (PVC, etc.) (Note 1)
ø200 to
Metal pipe (SS, steel pipe,
FSGS41
ø1200 mm
-40 to 80°C
copper pipe, aluminum pipe, V or Z
method
ø200 to
etc.) (Note 2)
FSGS5
ø6000 mm
FSD32 ø50 to ø400 mm
-40 to 200°C
Note 1: If the pipe material is PP or PVDF, select FSGS31, FSGS41 or FSGS5.
Note that the wall thickness is 15mm or less for PP, and 9mm or less for PVDF.
Note 2: For cast iron pipe, lining pipe, old steel pipe or others through which the ultrasonic
signal could not be transmitted easily, select FSGS31,FSGS41 or FSGS50.
Lining material: Tar epoxy, mortar, rubber, etc.
* In case the lining is not glued to a pipe, the measurement may be impossible.
Straight pipe length: Typically 10D for upstream and 5D for dowstream.
(D: Pipe inner diameter)
Refer to conditions on straight pipe for details
(Japan Electric Measuring Instruments Manufacturers'
Association Standard JEMIS-032).
Note 3: If silicone-free grease is used as acoustic coupler, the fluid temperature range is
0 to 60°C regardless of the detector.
Note 4: When the 9th digit in the code symbol is “A”, the applicable piping diameter is up
to 150mm.
2
Performance specifications
Rated accuracy:
Detector
Pipe size
(diameter)
Applicable pipe
material
ø25 to ø50 mm
Plastic
FLSE12 ø50 to ø100 mm
Popular type
100 to 240V AC +10%/-15%, 50/60Hz;
or 20 to 30V DC
Signal cable (between detector and converter):
Coaxial cable (5m standard, 300m (60m
for popular detector (FLS)) max.)
Heat resistance: 80°C
Installation environment:
Non-explosive area without direct sunlight, corrosive gas and heat radiation.
Ambient temperature:
Flow transmitter: -20 to +55°C
Detector: -20 to +60°C
-20 to +80°C
(for FLSE22-A only)
Ambient humidity:
95%RH max.
Grounding:
Class D (100 Ω)
Arrester:
Provided as standard at output and
power supply
Applicable piping and fluid temperature:
ø50 to ø100 mm Metal pipe
FLSE22
ø50 to ø225 mm
ø13 to ø50 mm
FSD22
ø50 to ø100 mm
FSGS32 ø50 to below ø300
FSD32
FSGS51 ø300 to ø6000 mm
FSGS31 ø50 to below ø300
FSGS41
FSGS50 ø300 to ø6000 mm
Flow velocity Accuracy
2 to 32m/s
0 to 2m/s
2 to 32m/s
0 to 2m/s
2 to 32m/s
0 to 2m/s
2 to 32m/s
0 to 2m/s
2 to 32m/s
Metal pipe
0 to 2m/s
2 to 32m/s
0 to 2m/s
2 to 32m/s
0 to 2m/s
2 to 32m/s
0 to 2m/s
Plastic, metal pipe
0.75 to 32m/s
0 to 0.75m/s
2 to 32m/s
0 to 2m/s
0.75 to 32m/s
0 to 0.75m/s
ø50 to ø225 mm Plastic
Common type
Power supply:
±2.0% of rate
±0.04m/s
±1.0% of rate
±0.02m/s
±2.0% of rate
±0.04m/s
±1.0% of rate
±0.02m/s
±2.0% of rate
±0.04m/s
±1.5% to ±2.5% of rate
±0.03 to ±0.05m/s
±1.5% of rate
±0.03m/s
±1.0% of rate
±0.02m/s
±1.0% of rate
±0.0075m/s
±1.5% of rate
±0.03m/s
±1.5% of rate
±0.0113m/s
Response time: 0.5s (standard mode)
0.2s as selected (quick response mode)
Power consumption:
15VA max. (AC power supply)
6W max. (DC power supply)
Functional specifications
Analog signal:
Digital output:
4 to 20mA DC (1 point)
Load resistance: 1 kΩ max.
Forward total, reverse total, alarm,
acting range, flow switch, total switch
assignable arbitrarily
(1) Mechanical relay contact (isolated,
socket provided, arrester incorporated)
• Output: 1 point
• Normal: Open/Close selectable
• Contact capacity: 240V AC, 30V DC, 1A
• Output frequency: 1P/s max. (pulse
width: 50, 100, 200ms)
(2) Transistor contact (isolated, open collector, arrester incorporated)
• Outputs: 2 points
• Normal: ON/OFF selectable
• Contact capacity: 30V DC, 0.1A
• Output frequency: 1000P/s max. (pulse
width: 5, 10, 50, 100, 200ms)
Digital input:
1 point (no-voltage contact) (option)/
Set zero, Preset total assignable
Serial communication (option):
RS-232C equivalent or RS-485, isolated,
arrester incorporated
Connectable quantity: 1 unit (RS-232C)/up
to 31 units (RS-485: MODBUS)
Baud rate: 9600, 19200, 38400bps
Parity: None/Odd/Even selectable
Stop bits: 1 or 2 bits selectable
Cable length: 15m max. (RS-232C)/1km
max. (RS-485)
Data: Flow velocity, flow rate, forward
total, reverse total, status, etc.
Display device: 2-color LED (Normal: green, Extraordinary: red)
LCD with 2 lines of 16 characters and
back light
Indication language:
Japanese (Katakana)/English/French/
German/Spanish (changeable)
Flow velocity/flow rate indication:
Instantaneous flow velocity, instantaneous
flow rate indication (minus indication for
reverse flow)
Numerals: 8 digits (decimal point is
counted as 1 digit)
Unit: Metric/Inch system selectable
Velocity
Metric system
Inch system
m/s
ft/s
Flow rate L/s, L/min, L/h, L/d,
k L / d , M L / d , m 3/ s ,
m 3/min, m3/d, km3/d,
Mm 3/d, BBL/s, BBL/
min, BBL/h, BBL/d,
kBBL/d, MBBL/d
Note: The ”gal” means USgal.
gal/s, gal/min, gal/h,
gal/d, kgal/d, Mgal/
d, ft3/s, ft3/min, ft3/d,
Kft 3/d, Mft3/d, BBL/s,
BBL/min, BBL/h, BBL/d,
kBBL/d, MBBL/d
Total indication: Forward or reverse total value indication (negative indication for reverse
direction)
Numerals: 8 digits (decimal point is
counted as 1 digit)
Unit: Metric/Inch system selectable
Metric system
Total
Inch system
mL, L, m3, km3, Mm3, gal, kgal, ft3, kft3, Mft3,
mBBL, BBL, KBBL
mBBL, BBL, kBBL,
ACRE-ft
Configuration:
Fully configurable from the 4-key pad
(ESC,
, , ENT)
Zero adjustment:Set zero/Clear available
External zero adjustment:
Set zero available upon digital input
setting
Damping:
0 to 100s (every 0.1s) for analog output
and flow velocity/flow rate indication
Low flow rate cutoff:
0 to 5m/s in terms of flow velocity
Alarm:
Digital output available for Hardware
fault or Process fault
Burnout:
Analog output: Hold/Overscale/Underscale/Zero selectable
Flow rate total: Hold/Count selectable
Burnout timer: 0 to 100s (every 1s)
Bi-directional range:
Forward and reverse ranges configurable independently.
Hysteresis: 0 to 10% of working range
Working range applicable to digital
output
Auto-2 range: 2 forward ranges configurable independently
Hysteresis: 0 to 10% of working range
Working range applicable to digital
output
Flow switch:
Lower limit, upper limit configurable
independently
Digital output available for status at
actuated point
Total switch:
Forward total switching point configurable
Digital output available when actuated
External total preset:
Preset total settable upon contact input
setting
Physical specifications
Type of enclosure:
Flow transmitter:FSV···S: IP66
FSV···H: IP67 (With
large LCD)
Detector:
FLS (popular type):
IP65 (When waterproot BNC connector is provided)
FSG (common type):
IP67 (Silicone compound is filled
on the terminal part when wiring)
FSG (submersible type):
IP68 (submersible in water for 5
days)
FSD (small diameter and high temperature type): IP52
Mounting method:
Flow transmitter: Mounted on wall or by
2B pipe
Detector: Clamped on pipe surface
Acoustic coupler:
Silicone rubber, silicone grease or siliconefree grease
Note: The acoustic coupler is a medium
that eliminates a gap between
detector and pipe
Type of acoustic coupler:
Type
Fluid
temperature
Silicone
rubber
(KE-348W)
Silicone
grease
(G40M)
Silicone-free Grease for
grease
high
(HIGH Z)
temperature
(KS62M)
-40 to +150°C -30 to +150°C 0 to +60°C
-30 to +250°C
Teflon piping
In case of Teflon piping, use grease.
Procure silicone grease (G40M), if necessary, as an optional
accessory.
Material:
Flow transmitter: Aluminum alloy
Detector:
Detector Sensor housing Sensor cover Guide rail
–
FLSE1
PBT
SUS304
–
FLSE2
PBT
SUS304
–
FSD22 PBT
Aluminum alloy + plastic
FSGS3 PBT
SUS304
SUS304 + plastic
–
FSGS41 PBT
SUS304
FSGS5
FSD32 SUS304
–
SUS304 + aluminum alloy
3
FSV, FLS/FSG/FSD
Signal cable:
FLY3 (applicable detector: FLS)
•Structure: Heat-resisting high-frequency
coaxial cable (3D2V)
•Sheath: Flame-resisting PVC
•Outer diameter: ø5mm
•T ermination: M3 amp terminal (flow
transmitter side) and BNC connector
(sensor side)
FLY8, FLY9 (applicable detector: FSG,
FSD)
•Structure: High frequency coaxial cable
(double shield)
•Sheath: Black flame-resisting PVC
•Outer diameter: ø7.3mm
•T ermination: M3 amp terminal (flow
transmitter side) and M4 amp terminal
(FLY8).Note, however, that the detecter
side of FSD22 and FSD32 is provided
with BNC connector (FLY9).
•Mass: Approx. 90g/m
Dimensions:
Flow transmitter FSV···S (IP66):
H170×W142×D70mm
Flow transmitter FSV···H (IP67):
H277×W244×D95mm
Detector: H50×W228×D34mm (FLSE1)
H50×W348×D34mm (FLSE2)
H90×W320×D53mm (FSD22)
H46×W410×D50mm (FSGS3)
H46×W54×D37mm (FSGS41)
H67×W78×D84mm (FSGS5)
H205×W530×D52mm (FSD32)
Mass:
MEASURING PRINCIPLE
CONFIGURATION DIAGRAM
With ultrasonic pulses propagated diagonally between the
upstream and downstream sensors, flow rate is measured
by detecting the time difference obtained by the flow of
fluid.
Detector
θ
Flow velocity
t1
(indoor type):
(outdoor type):
(FLSE1)
(FLSE2)
(FSD22)
(FSGS3)
(FSGS4)
(FSGS5)
(FSD32)
PC Loader software
Provided as standard
•Compatible model is PC/AT compatible instrument.
•Operation is undefined for PC98 series (NEC).
•Main functions: Software for Main unit parameter setting/change on PC
•OS: Windows 2000/XP
•Memory requirement: 125MB min.
•Disk unit: CD-ROM drive compatible with Windows
2000/XP
•Hard disk capacity: Minimum vacant capacity of 52MB
or more
Note:Optional communication board (specified at the
5th digit of code symbols) and loader cable (Model
ZZP*TK4J1236) are additionally necessary for RS232C
serial communication.
Note:USB-RS232C converter
For PC that does not support RS-232C serial interface,
a converter is necessary for connecting the PC and
main unit.
USB-RS232C converter should be combined with the
above loader cable.
<Recommendation>
USB-CVRS9 (manufactured by Sanwa Supply)
(1) Single-path system (V method)
Cable
Detector
Upstream sensor
D
t2
Flow transmitter
1.5kg
Flow transmitter
4.5kg
Detector: 0.3kg
0.4kg
0.6kg
0.6kg
0.3kg
1.2kg
1.6kg
DC
4 to 20mA
Flow
transmitter
Output signal
Digital signal
(Up to 2 point)
Flow transmitter
(2) Single path system (Z method)
Downstream sensor
Cable
MOUNTING OF DETECTOR
Ultra sonic
oscillator
Plastic wedge
Pipe
Lining
4
Detector
DC
4 to 20mA
Flow
transmitter
Digital signal
(Up to 2 point)
DETECTOR SELECTION GUIDE
Type
Fluid
Mounting
temperature [°C] method
-20 to 100
FLSE12
2-Y
FLSE12
2-A 0 to 120
2-Y
FLSE22
2-A 0 to 120
50
25
P
V
-20 to 100
FLSE22
Inner diameter of piping ø (mm)
13 25
50
M
50
V
200
250
300
400
1000
3000
6000
100
100
P, M
50
V
FSGS32 Note)
FSGS31
100
P, M
50
225
150
Px, P, M
300
V
200
Z
200
V
200
Px, P, M
Z
200
Px, P, M
Px, P, M
600
-40 to 80
FSGS41
FSGS51 Note)
FSGS50
FSD22
-40 to 100
FSD32
-40 to 200
V
13
Px, P, M
V
50
Z
Classification of
piping materials
Px, P, M
1200
3000
6000
100
Px, P, M
150
250
Px, P, M
400
Px : PP, PVDF
P : Plastic (PVC, etc.)
M : Msetallic piping (steel pipe, copper pipe, aluminum, etc.)
Note: The ultrasonic signal cannot be transmitted easily when the classification of piping material is Px or the turbidity is high.
In such a case, a preliminary check by a portable ultrasonic flowmeter is recommended.
CODE SYMBOL
<Detector, small diameter/high temperature type>
<Flow transmitter>
1 2 3 4 5 6 7 8
F SV
Y
9 10 11 12 13
1
14
Y
Description
(Destination) (4th digit)
Standard (English)
E
(Communication) (5th digit)
None
RS232C+DI
RS485+DI
Y
A
B
(Use) (6th digit)
Single measuring path
Y
(Power supply) (7th digit)
AC100 to 240V 50/60Hz
DC20 to 30V
1
4
(Case structure) (9th digit)
IP66
IP67
S
H
1 2 3 4 5 6 7 8
Description
F SD2 2 0S 1
Small diameter sensor (ø13 to ø100) V method
F SD3 2 0Y 1
High-temperature sensor *1 (ø50 to ø400)
V or Z method
*1: For turbid fluid or old pipe, cast iron pipe, mortar lining pipe or
others through which the ultrasonic signal could not be
transmitted easily, use an optional guide rail (TK4C6164C1), and
carry out mounting by Z method.
Applicable diameter range
V method: ø50 to ø250
Z method: ø150 to ø400
Note: As standard acoustic coupler, silicone rubber (KE-348W) is
provided for small diameter sensor, or grease for high
temperature (KS62M) for high-temperature sensor.
(Wire connection port) (10th digit)
Weatherproof gland provided
[G1/2 and G3/8 (internal threads)]
Union (for pilica) with gland
[G1/2 female screw]
(when "H" is specified 9th digit)
Y
A
(Combination with explosion-proof
detector) (11th digit)
None
Y
(Parameter setting) (12th digit)
None
Setting provided
Setting provided + tag
Tag
Y
A
B
C
(Mounting method) (13th digit)
Pipe mount (if the 9th digit is S)
Wall mount
Pipe mount (if the 9th digit is H)
A
B
C
N
E
A
(Area) (14th digit)
America
Europe, Middle East, Africa
Asia
5
FSV, FLS/FSG/FSD
CODE SYMBOL
<Detector, common type>
1 2 3 4 5 6 7 8
9 10 11 12 13
F SGS
Y
Y1
3
3
4
5
5
1
<Detector, popular type>
Description
Type (5th and 6th digits)
Small sensor 2MHz (ø50 to ø300)
V method
Small sensor 1MHz (ø50 to ø300)*2
Middle sensor 1MHz (ø200 to ø1200)
V or Z
Large sensor 1MHz (ø200 to ø6000)
method
Large sensor 0.5KHz (ø200 to ø6000)*2
2
1
1
1
0
Acoustic coupler (10th digit)
None*5
Silicon rubber (KE348)
Silicone-free grease (HIGH-Z) (Note 2)
Silicone grease (G40M) (Note 2)
Additional specification (11th digit)
None
Tag plate
Y
A
B
C
Y
A
Wire rope for mounting (12th digit)
Specify it in the case of FSGS41 or FSGS5.
None
Nominal diameter: up to ø500mm
Nominal diameter: up to ø1000mm
Nominal diameter: up to ø1500mm
Nominal diameter: up to ø3000mm Can be specified
Nominal diameter: up to ø6000mm only for FSGS5
Y
A
B
C
D
E
*2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts
the propagation of ultrasonic signals, select FSGS31 or FSGS50.
*3: Procure type FLY for the signal cable.
*5: Silicone rubber (KE-348W) is provided as a standard accessory to fill
the wiring mold. (It can also be used as an acoustic coupler.)
If an additional acoustic coupler is required, select one among A, B
and C.
<Detector, submersible type>
1 2 3 4 5 6 7 8
F SGS
9 10 11 12 13
A1
3
3
4
5
5
1
Description
Type (5th and 6th digits)
Small sensor 2MHz (ø50 to ø300)
V method
Small sensor 1MHz (ø50 to ø300)*2
Middle sensor 1MHz (ø200 to ø1200)
V or Z
Large sensor 1MHz (ø200 to ø6000)
method
Large sensor 0.5KHz (ø200 to ø6000)*2
2
1
1
1
0
Dedicated signal cable (9th digit)
10m
20m
30m
40m
50m
60m
70m
80m
90m
100m
110m
120m
130m
140m
150m
Specified length
(Contact us if length is more than 150m.
Max. length is 300m.)
Acoustic coupler (10th digit)
Silicon rubber (KE348)
Silicone grease (G40M) (Note 2)
Additional specification (11th digit)
None
Tag plate
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
Z
A
C
Y
A
Y
A
B
C
D
E
Wire rope for mounting (12th digit)
Specify it in the case of FSGS41 or FSGS5.
None
Nominal diameter: up to ø500mm
Nominal diameter: up to ø1000mm
Nominal diameter: up to ø1500mm
Nominal diameter: up to ø3000mm Can be specified
Nominal diameter: up to ø6000mm only for FSGS5
*2: For aging pipes, cast iron pipes or mortar-lined pipes that interrupts
the propagation of ultrasonic signals, select FSGS31 or FSGS50.
6
1 2 3 4 5 6 7 8
F L SE
9 10
3
Description
Type (4th, 5th and 6th digits)
Small diameter sensor, 2MNz
(ø25 to ø100mm)
Small sensor, 2MHz
(ø50 to ø225mm) (Note 1)
1 2
2 2
V method
Acoustic coupler (7th digit) (Note 2)
None
Silicone rubber
Silicone-free grease
Y
A
B
Fluid temperature range (9th digit)
-20 to +100°C
0 to +120°C
Y
A
Y
B
Optional specification (10th digit)
None
Tag
Note 1: When the 9th digit in the code symbol is “A”,
the applicable piping diameter is up to 150mm.
Note 2: Normally select silicone rubber as acoustic coupler. Silicone
rubber in tube (100g) is furnished. If you place an order for
several units, 1 tube may suffice for every 5 units.
Select silicone-free grease for semiconductor manufacturing
equipment or the like that is vulnerable to silicone. The
silicone-free grease is water-soluble and, therefore, cannot be
used in environment exposed to water or on piping subjected
to a condensation. Since the grease does not set, a periodic
maintenance (cleaning, refilling every about 6 months at
normal temperature) is necessary.
CODE SYMBOL
<Signal cable>
• For detector FSG and FSD
• For detector FLS
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1
F L Y
Type of sensor (4th digit code)
(for FLS)
3
0
0
0
0
0
0
0
0
0
Z
0
1
1
2
2
3
4
5
6
Z
5
0
5
0
5
0
0
0
0
Z
1
F L Y
Description
8
9
Cable length (5, 6 and 7th digit)
5m
10 m
15 m
20 m
25 m
30 m
40 m
50 m
60 m
Others (contact us)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
Z
Conditions on straight pipe
Description
Type of sensor (4th digit)
Small and large sensor (for FSG)
Small dia and hight temp sensor (for FSD)
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
1
2
3
4
5
Z
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
0
0
0
0
0
Z
Cable length (5,6 and 7th digit)
5m
10 m
15 m
20 m
25 m
30 m
35 m
40 m
45 m
50 m
55 m
60 m
65 m
70 m
75 m
80 m
85 m
90 m
95 m
100 m
110 m
120 m
130 m
140 m
150 m
Others (contact us)
Note: Must be procured unless the sensor is a submersible type.
( D : Inside diameter of pipe)
Classification
Upstream side
Downstream side
90 bend
10D or more
L 5D
L 10D
10D or more
Detector
Tee
L 10D
L 50D
0.5D
or more
10D or more
L 30D
L 5D
D
Diffuser
1.5D
L 10D
L 50D
Reducer
L 30D
L 10D
Various Valve
In case that flow control valve exists on
upstream side.
In case that flow control valve exists on
downstream side.
Stop valve
Check valve
L 50D
Pump
P
(Note) The source : JEMIS-032
7
FSV, FLS/FSG/FSD
OUTLINE DIAGRAM (Unit:mm)
U bolt (M8)
(option)
75
142
70
1
2-
Mtg. hole
1
10
ø9
72
10
9
2.5
U bolt (M8)
(option)
Mtg. plate
20
2.5
312
277
ENT
ESC
220
170
200
(233)
Ultrasonic Flow Meter
25
TIME
DELTA-C
SS tag
(option)
Cable gland
Mtg. pipe
Bracket
(option)
153
14
5.7
Earth terminal
(M4)
230
Earth terminal (M4)
95
39
Mtg. pipe
For sensor
cable (PF3/8)
40
For power supply & output cable (PG13.5)
40
40
Flow transmitter : FSV···S (IP66)
Flow transmitter : FSV···H (IP67)
SS tag (option)
(50)
H
L
Sensor
BNC connector
Frame
34
Spacing
Pipe size
(mm)
L
H
Spacing
Mass.
approx (kg)
FLSE12 25 to 100
228
31
21 to 120
0.3
FLSE22 50 to 225
348
30
21 to 240
0.4
Type
Detecter (type : FLSE 2) (popular type)
8
28
Lock clip
(Adjustable every 3mm)
40
For sensor
cable (PF1/2)
For power supply
& output cable (PF1/2)
OUTLINE DIAGRAM (Unit:mm)
Saddle
Connector
Scale(inch)
Saddle
Scale(mm)
Name plate
320
Lock nut
Element holder
Lock nut
Element holder
inch
Cursor
530±2
Distance between two
sensors 0 to 133
Scale
(mm)
Distance between
two sensors 0 to 330
mm
Connector
Scale
(inch)
Cursor
36
φ26
33±0.5
90 max.
90max.
205max.
52.5
Detector FSD22 (Small diameter sensor)
44±1
Detector FSD32 (High-temperature sensor)
5
Frame
Sensor
410±2
400
5
Sensor
410±2
400
5
5
P
L (cable length (m) : specified by order)
Frame
P
Name plate
Name plate
47
Spacing : 0 to 270
47
Spacing : 0 to 270
50±1
33
Chain
50±1
33
46±1
Mounting spring
Chain
46±1
Mounting spring
(10)
VIEW FROM P
(Common type)
Frame guide
(Submersible type)
Detector FSGS3 (Small sensor)
Name plate
84±1
84±1
Name plate
114
114
Wire rope
78±1
Sensor
Mounting spring
L(cable length (m) : specified by order)
Wire rope
Mounting spring
Ø19
67±1
ø19
78±1
Sensor
67±1
(10)
Frame guide
VIEW FROM P
(Common type)
(Submersible type)
Detector FSGS5 (Large sensor)
9
FSV, FLS/FSG/FSD
OUTLINE DIAGRAM (Unit:mm)
Name plate
54±1
Name plate
114
54±1
Sensor
114
Sensor
Wire rope
L (cable length (m) : specified by order)
(Common type)
Ø19
46±1
Ø19
46±1
37±1
Wire rope
Mounting spring
37±1
Mounting spring
(Submersible type)
Detector FSGS41 (Middle sensor)
Signal cable : FLY3 (For FLS)
Signal cable : FLY8 (For FSG)
ø15
8
BNC connector
41
3-ø4.3
To Detector
30
To Detector
L (cable length (m) : specified by order)
L (cable length (m) : specified by order)
ø11
ø5
ø7.3
To Flow transmitter
To Flow transmitter
L : By specification
when ordered.
ø3.
2
3-ø3.2
L : By specification
when ordered.
5.5
5.5
Signal cable : FLY9 (For FSD)
Loader cable : ZZP*TK4J1236
34
Connector
ø14.5
46
BNC connector
67
30
To Detector
To Flow transmitter
3-ø3.2
10
To Personal
computer
ø7.3
3.2±0.2 (m)
L (cable length (m) : specified by order)
ø11
5.5
L : By specification
when ordered.
ø6.9
To Flow transmitter
Terminal cap
(Red)
3ø3
.2
Terminal cap (Yellow)
Terminal cap (Black)
5.5
Red
Yellow
Black
TXD
RXD
COM
RS-232C
CONNECTION DIAGRAM
<Flow transmitter>
Earth terminal
(M4)
<Detector>
AC power supply
1
2
L
N
3
DC power supply
4
AC100 to 240V
50/60Hz
1
1
2
+
−
1
4
DI1
DC20 to 30V
2
3
4
5
6
7
8
9
−
+
−
+
−
+
− GND HF1 GND HF2
DO2
TR out
DO3
RELAY
11
12
13
*1
SH
I out
Max. DC30V, 0.1A Max. AC240V/
DC30V, 1A
2
*1
SH
To downstream-side
sensor
3
+
4
SHILD TXDR2 TXDR1
Status input
(DI)
+
DO1
TR out
10
G
Option
3
RS-485
To flow
transmitter
1
2
3
4
DI1
GND
RXD
TXD
Status input
(DI)
RS-232C
To upstream-side sensor
*1) Only for double shield coaxial cable (type FLY8, 9)
SCOPE OF DELIVERY
ITEMS DESIGNATED ORDERING
•Flow transmitter (provided with U-bolt and nuts for pipe
mount)
•Detector (provided with mounting fixture and acoustic
coupler)
*The acoustic coupler is option for popular type detectors.
•Signal cable
•CD-ROM (contains instruction manual, loader software)
1.Detector code symbols
2.Flow transmitter code symbols
3.Signal cable code symbols
4.For large sensor: Mounting pipe size
5.Tag No. as necessary
6.If parameter setting is specified, send back the attached
parameter specification table duly filled.
OPTIONAL ACCESSORIES
Name
Drawing No.
1 Guide rail for high-temperature sensor
ZZP*TK4C6164C1
2 PC Loader cable
ZZP*TK4J1236C1
3 Silicon grease (G40M)
ZZP*45231N5
4 Silicone rubber (KE 348W)
ZZP*45735N2
5 Silicone-free grease (HIGH Z)
ZZP*TK7M0981P1
6 High-temperature grease (KS62M)
ZZP*TK7G7983C1
7 Fuse for AC power
ZZP*TK7N3827P8
8 Fuse for DC power
ZZP*TK7J1005P1
9 Wire rope for mounting the sensor
Spring
ZZP*TK745007P1
Wire rope
Nomal diameter: up to ø500mm
ZZP*TK464686C1
Nomal diameter: up to ø1000mm
ZZP*TK464686C2
Nomal diameter: up to ø1500mm
ZZP*TK464686C3
Nomal diameter: up to ø3000mm
ZZP*TK464686C6
Nomal diameter: up to ø6000mm
ZZP*TK464686C13
11
FSV, FLS/FSG/FSD
<Parameter specification table>
Setting item
Initial value
Setting value
Setting item
Initial value
Total mode
Stop
English
Total rate
0m3
Total preset
0m3
Pulse width
50.0msec
Burnout (total)
Hold
Burnout timer
10sec
Metric
Flow unit
m3/h
Total unit
m
Outer diameter
60.00mm
Pipe material
PVC pipe
Wall thickness
4.00mm
Lining material
Without lining
Lining thickness
−
Kind of fluid
Water
DO3 output type
Not used
Viscosity
1.0038×10-6m2/s
DO3 output actuation
ON when actuated
Sensor mount
V metod
DI1 input type
Not used
Sensor type
FLS_12
DI1 input actuation
ON when actuated
Transmission voltage
80Vpp
Operation mode
Standard
Damping
5.0sec
Communication mode
RS-232C
Cut off
0.150m /h
Baud rate
9600bps
Parity
Odd
Stop bit
1 bit
Station No.
1
Output conditions
3
Communication
Display
System unit
Analog output
Output conditions
Total output
0000
Language
Measuring conditions
ID No
3
1st line
Flow velocity (m/s)
1st line decimal point position
****.***
2nd line
Flow rate (m3/h)
2nd line decimal point position
****.***
Range type
Single range
Full scale 1
15.000m3/h
Full scale 2
0.000m3/h
Range HYS.
10.00%
Burnout (current)
Hold
Burnout timer
10sec
Output low limit
-20%
Output high limit
120%
Rate limit
0.000m3/h
Rate limit timer
0sec
DO1 output type (Note 1)
Not used
DO1 output actuation
ON when actuated
DO2 output type
Not used
DO2 output actuation
ON when actuated
Setting value
Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that
conditions 1 and 2 shown below are satisfies.
Condition 1 :
Condition 2 :
Flow span-1*[m3/s]
total pulse value*[m3]
1000 [In the case of DO1 and DO2]
1 [In the case of DO3]
Flow span-1*[m3/s]
1000
total pulse value*[m3]
2 × total pulse width [ms]
* In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater.
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/
Information in this catalog is subject to change without notice.
Printed in Japan