FUJI EDSX6-111E

SERIES
ULTRASONIC FLOWMETER <
F (Flexible Type)>
FLH…3, FLW…2, FLD…1
DATA SHEET
This flowmeter is a fixed type ultrasonic flowmeter based on
transit-time measuring method. Thanks to micro-processor
based electronics, the flowmeter can be easily configured
from the keyboard to specific applications, the flowmeter is
suitable for liquid flow measurements for pipe size 50mm to
6000mm diameter.
The flowmeter is a compact and light-weight instrument
incorporating the latest electronics and high speed digital
signal processing technologies (32bit MPU), realizing high
performance and easy operation. This high performance
flowmeter is capable of realizing a simultaneous 2-path or
2-pipe system.
Flow transmitter (FLH)
FEATURES
1. Compact and light-weight
This flowmeter is designed through use of the latest electronics and digital signal processing technologies.
2. Full variety of sensors
The flowmeter can be used with various types of sensors
applicable for small to large pipe (ø50 to ø6000mm) and
low to high fluid temperature (-40 to +200°C).
3. High accuracy
The flowmeter is designed for high accuracy (better than
±1.0% of rate) by dynamic correction of fully-developed
flow profile. Reynolds Number is calculated and a meter
factor (K) is automatically applied for best accuracy at all
flow velocities.
The adoption of new sound velocity measurement system
permits measurements of fluids of unknown sound velocity with slightly affecting from fluid temperature and pressure.
4. Excellent resistance against aerated flow
Fuji' s unique ABM feature improves measurement reliability for different flows like slurries, sludge, raw sewage
and bubble-contained flow (acceptable up to air bubbles
of 12% volume at 1m/s velocity).
5. Simultaneous 2-path or 2-pipe system
Average flow rate on 2 propagation paths can be measured simultaneously with less influence from changes in
time of flow profile. And also flow measurement in two
separate pipes with one FLH3 can be realized for calculating functions of flow.
6. Excellent performance and easy operation
Large LCD and function keys allow easy configuration and
trouble shooting.
– LCD with back light
– Easy mounting of sensor
– Trouble shooting
Small sensor (FLW12)
SPECIFICATIONS
Fluid conditions
Measured flow : Liquid flow through which ultrasonic signal
can be transmitted (water, sea water, oil
and fluid having unknown sound velocity)
10000deg (mg /L) or less
Turbidity :
State of flow : Turbulent or Imainor uniform flow well
grown up
Fluid temperature :
Small sensor
Middle sensor
-40 to +80°C
Large sensor
High-temperature sensor -40 to +200°C
Velocity range : -32 to 0 to +32m/s
Piping conditions
Pipe material :
Carbon steel, ss, cast iron, polyvinyl chloride, FRP, asbestos, copper, aluminum,
acryl, etc.
Pipe size :
Small sensor
ø50 to ø400
Middle sensor
ø200 to ø1200
Large sensor
ø200 to ø6000
High-temperature sensor
ø50 to ø400
Lining material : None, tar epoxy, mortar, rubber, or other
material with known sound velocity
Straight pipe length :
Upstream, 10D or more
Downstream, 5D or more (D= Inside diameter of pipe)
Refer to JEMIS-032 for details.
JEMIS :
Japan Electric Measuring Instruments
Manufacturers’ Association’s standard.
EDSX6-111e
Date
July. 15, 2008
FLH…3, FLW…2, FLD…1
Enclosure :
Accuracy
Inside diameter
ø50 to ø300 mm
ø300 to ø6000 mm
Velocity
2 to 32 m/s
0 to 2 m/s
1 to 32 m/s
0 to 1 m/s
Accuracy
±0.5% to 1.0% of rate
0.02 m/s
±0.5% to 1.0% of rate
0.01 m/s
Material :
Kind
Sensor case
Guide rail
Small sensor
Plastic
(Note) Reference conditions are based on JEMIS-032.
Middle sensor
Plastic
–
Flow transmitter (FLH)
Large sensor
304SS
304SS + aluminum
Measuring system :
Simultaneous 2-path or 2-pipe or single-path
Power supply : 100 to 120V AC, 200 to 240V AC ±10%
(50/60Hz)
Power consumption :
About 50VA
Indicator display : Character LCD (16-digit, 2-line), with back light
Operation unit : Sheet key (20 keys)
Power failure protection :
Backup with non-volatile memory (effective
term; more than 10 years)
Response time: 1.5 sec or less
Output signal : Analog signal 4 t o 2 0 A D C ; 2 - p a t h ,
2-pipe: 3 points, singlepath: 2 points (load resistance: 0-1kΩ )
Contact signal O p e n c o l l e c t o r ( 3 0 V
DC/0.1A); 2-path, 2-pipe:
6 points, single-path: 4
points
BCD output
Open collector (30V DC/
(option)
0.1A, insulated, negative
logic); 1 set (6 digits with
parity), with connector, 37
pins, D-sub and cable (2m)
Communication : RS-232C or RS-485 (equivalent) changeable, 1 channel
Baud rate: 2400 to 9600bps
Distance: 15m max. for RS-232C,
1km max. for RS-485
Ambient temperature :
-10 to +50°C
Ambient humidity :
90%RH or less (no condensation)
Enclosure :
Immersion-proof (aluminum casting case)
IP65 or equivalent
Finish color :
Cover (blue), case (silver)
External dimensions :
H320×W240×D134mm
Mass :
About 9kg
Detector (FLW)
Mounting :
Clamp-on outside of existing piping
Sensor mounting method :
V or Z method
Mounting belt/wire :
Small sensor; stainless chain
Middle sensor;
stainless wire
Large sensor;
High-temperature sensor; stainless belt
Acoustic coupler :Silicone grease for high temp.sensor, silicone rubber for others
Signal cable :
Special coaxial cable, 150m max.
Connection method :
BNC connector for high-temperature sensor, terminal screws for others.
Ambient temperature :
-20 to +60°C
Ambient humidity :
100%RH or less
2
Enclosure: Immersion-proof (IP67 or equivalent), drip-proof for high-temperature sensor (IP52 or equivalent)
The submersible type can withstand being
underwater for several days.
High-temperature
sensor
304SS + plastic
alloy
Dimensions/mass :
Kind
Dimensions (H×W×D) Mass
Small sensor
510×80×40mm
1.0 kg
Middle sensor
72×80×40mm
0.4 kg
Large sensor
104×93×62mm
1.4 kg
High-temperature 530×52×205 mm
1.6 kg
sensor
FUNCTIONS
Display language :
Japanese (Katakana) or English, selectable
Flow rate display function :
Velocity or flow rate, selectable; unit selectable from metric and inch system
Metric system
Velocity
m/s
Flow rate L/s,L/m,L/h, ML/d
m3/s, m3/m,
m3/h, Mm3/d
BBL/s, BBL/m,
BBL/h, MBBL/d
Inch system
ft/s
gal/s, gal/m, gal/h,
Mgal/d, ft3/s,
ft3/m, ft3/h, Mft3/d
BBL/s, BBL/m,
BBL/h, MBBL/d
Total value display function :
Total value in forward or reverse direction,
selectable; unit selectable from metric
system and inch system
Metric system
Total
value
Inch system
mL, L, m3, km3, gal, kgal, ft3,
kft3, Mft3, mBBL,
Mm3, mBBL,
BBL, kBBL
BBL, kBBL
Instantaneous value output function :
Analog or BCD output
Calculating functions :
Average, sum or difference of two measured flow rate for 2-path or 2-pipe system
Damping :
0-100sec (time constant)
Low-flow cut : Approx. 0-5m/s or equivalent
Output setting function :
Setting of current output scaling/limit,
burnout. Current output calibration is possible.
Communication function :
Velocity, flow rate, total, status
Auto range selection :
2 ranges, range discriminated by contact
output
Forward/reverse range output :
Forward/reverse range, flow direction discriminated by contact output
Total pulse output :
1P/day to 5P/s, pulse width (50, 100ms,
selectable), total constant setting
Other :
Flow switch, total switch, self-diagnosis
function
MEASUREMENT PRINCIPLE
MOUNTING OF DETECTOR
Ultrasonic pulses are propagated aslant between the upstream and downstream sensors, detecting the time difference due to flow for measurement.
Ultrasonic oscillator
Plastic wedge
Pipe
Upstream sensor
Lining
Q
t1
Output signal
Flow
transmitter
D
t2
Velocity V
Downstream sensor
CONFIGURATION DIAGRAM
(1) Single-path system (V method)
(4) 2-path system (Z method)
Cable
Cable
Flow
transmitter
Detector
4-20mA DC (up to 2 points)
Contact (up to 4 points)
Detector
Flow
transmitter
4-20mA DC (up to 3 points)
Contact (up to 6 points)
(2) Single-path system (Z method)
(5) 2-pipe system (with any combination of sensors)
Cable
Flow
transmitter
Detector
4-20mA DC (up to 2 points)
Contact (up to 4 points)
Flow
transmitter
4-20mA DC (up to 3 points)
Contact (up to 6 points)
(3) 2-path system (V method)
Cable
Detector
Flow
transmitter
4-20mA DC (up to 3 points)
Contact (up to 6 points)
3
FLH…3, FLW…2, FLD…1
DETECTOR SELECTION
Fluid temperature (°C)
200
High-temperature sensor
(FLD3)
100
80
Small
diameter
sensor
(FLD2)
0
– 40
(Note)
13
Small sensor
(FLW1)
50
100
Middle sensor
(FLW4)
200
400
1200
Large sensor
(FLW5)
6000 Pipe size (mm)
1. High turbid fluid or scales sticking on the internal wall of pipes may interrupt the ultrasonic propagations.
Previous check with a portable type ultrasonic flowmeter is recommended.
2. In case of cast iron pipes or pipes with lining, the Large sensor is recommended rather than the Middle sensor.
3. If the pipe has poor inside surface conditions or highly attenuating fluids, you may not be able to a reliable signal, therefore you should use the ”FLW50˝ sensor.
SCOPE OF DELIVERY
Flow transmitter (FLH)
Unit name
Scope of delivery
1 Flow
1) Converter
transmitter 2) Parameter table (blank)
3) Manual
Detector (FLW)
Unit name
Scope of delivery
1 Small/high- 1) Sensor unit
tempera2) Signal cable (for subture/midmerged type)
dle/large
sensor
3) Mounting chain/wire/
belt
4) Silicone rubber/grease
(100g)
Signal cable (FLY)
Unit name
Scope of delivery
1 Signal cable Special cable (2pcs)
4
CODE SYMBOLS
<DETECTOR>
Standard type
<Flow transmitter>
1 2 3 4 5 6 7 8
F L H
9 10 11
3
Description
1 2 3 4 5 6 7 8
9 10 11 12
F LW
Y Y
Case structure
Immersion-proof structure
2
1
4
5
5
Data display
Japanese/English selection display
C
Application
Single-path
2-path or 2-pipe
Y
B
2
2
1
1
0
Y
A
Option
None
With BCD output
0
1
Y
T
Submerged type
1 2 3 4 5 6 7 8
9 10 11 12
F LW
Tag plate
None
With Tag plate
Y
1
4
5
5
2
1
1
0
0
1
1
1
1
<SIGNAL CABLE>
Description
Type of sensor (4th digit code)
Small, middle and large sensor (FLW120/410/510)
Small dia. and high temp. sensor (FLD 22/32)
1
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
1
2
3
4
5
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
0
0
0
0
0
Cable length (5, 6 and 7th digit)
5m
10 m
15 m
20 m
25 m
30 m
35 m
40 m
45 m
50 m
55 m
60 m
65 m
70 m
75 m
80 m
85 m
90 m
95 m
100 m
110 m
120 m
130 m
140 m
150 m
Note: No need to order signal cable of FLY when your ordering
submergence-proof or explosion-proof type sensor.
A pair of cables is provided as one unit.
(ø50 to ø400)
V method
(ø200 to ø1200) (Standard)
(ø200 to ø6000) V method
(ø200 to ø6000) or
Z method
Option
None
Tag name plate
Special cable
10 m
20
30
40
50
60
70
80
90
100
110
120
130
140
150
Other
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
Z
1 2 3 4 5 6 7 8
1
Description
Type
Small sensor
Middle sensor
Large sensor
Large sensor
Y
A
F L Y
V method
(Standard)
V method
or
Z method
Mounting method
Standard
Y
Z method
2
(Note) Signal cables are not provided with detector.
Signal cable FLY should be ordered separately.
Conduit connection
With cable gland
With cable gland for pulica tube
Y
A
Description
Type
Small sensor (ø50 to ø400)
Middle sensor (ø200 to ø1200)
Large sensor (ø200 to ø6000)
Large sensor (ø200 to ø6000)
Option
None
Tag name plate
0
0
0
0
Power supply
100 to 120V AC, 50/ 60Hz
200 to 240V AC, 50/ 60Hz
3
4
0
Y
2
Mounting method
Standard
Z method
(Note)
1.
High turbid fluid or scales sticking on the internal wall of pipes may interrupt
the ultrasonic propagations.
Previous check with a portable type ultrasonic flowmeter is recommended.
2. In case of cast iron pipes or pipes with lining, the Large sensor is recommended rather than the Middle sensor.
3. If the pipe has poor inside surface conditions or highly attenuating fluids, you
may not be able to a reliable signal, therefore you should use the ”FLW50”
sensor.
Small diameter and high-temperature sensor
1 2 3 4 5 6 7 8
F LD
9
Description
S1 - Y
Type
Small diameter sensor
(φ13 to φ100)
High-temparature sensor (Note) (φ50 to φ400)
2 2 0
3 2 0
Belt and Coupler
Fixed type
S
Y
Special cable
None
(Note)
Use the optional guide rail if a pipe that does not allow ultrasonic waves
to pass through easily such as an old pipe, cast iron pipe, or a pipe with
mortar lining is used, or when the flow of liquid high in turbidity is measured. Employ the Z method for mounting.
Applicable diameter range: V method: ø50 to ø250
Z method: ø150 to ø400
5
FLH…3, FLW…2, FLD…1
EXTERNAL OUTLINE DIAGRAM (Unit: mm)
With cable glands
With cable glands for plica tube
(JIS C 8309, No.1 7)
Scale
(inch)
Saddle
Scale
(mm)
33
(50A to 300A)
530
Mounting size 0 to 330
BNC connector
Lock nut
72
500
Mounting size (0 to 270)
Flow transmitter, FLH
Element holder
33
Sensor
Cursor
Pipe
Nameplate
φ26
33
90max
205max
Frame end
80
Gland terminal
40
60
52
Chain & spring
Detector, FLW1 (Small sensor)
6
Detector, FLD32 (High-temperature sensor)
72
104
Detector
114
114
GND terminal
93
Wire rope
60
Detector, main body
Mtg.spring
40
Wire rope
62
φ19
Mounting spring
φ19
Detector, FLW41 (Middle sensor)
Detector, FLW5 (Large sensor)
Saddle
Scale(inch)
Scale(mm)
320
Distance between
two sensors 0~133
BNC connector
Lock nut
Element holder
Cursor
36
90 max
52.5
Mounting device: SS belt
DETECTOR : FLD220 (Small diameter sensor)
7
FLH…3, FLW…2, FLD…1
CONNECTION DIAGRAM
(2) 2-path or 2-pipe system
(1) Single-path system
1
2
3
+
+
–
5
4
+
–
BCD output
6
RS485
SHLD
TRXD2
TRXD1
2
3
1
2
+
–
Analog Contact Contact
output output output
No.
1
2
3
1
SERIAL(RS485 or RS232C)
RS232C
COM
RXD(signal reception)
TXD(signal transmission)
3
4
+
–
5
+
–
BCD output
6
Analog Contact Contact
output output output
No.
1
2
3
RS485
SHLD
TRXD2
TRXD1
1
2
3
–
SERIAL(RS485 or RS232C)
RS232C
COM
RXD(signal reception)
TXD(signal transmission)
For 2-nd detector
1
2
3
4
5
6
+ – + – + –
Analog Contact Contact
output output output
7
8
9 10
G HF G
SH
To upstream sensor
Power supply
1
L
2
HF
1
2
3
SH
To downstream sensor
3
N
4
5
6
7
+ – + – + –
Analog Contact Contact
output output output
8
9 10
G HF G
HF
SH
To downstream sensor
SH
To upstream sensor
For 1-st detector
1
2
3
4
5
6
+ – + – + –
Analog Contact Contact
output output output
7
8
SH
To upstream sensor
Power supply
1
L
2
9 10
G HF G
HF
SH
To downstream sensor
3
N
ITEMS DESIGNATED ORDERING
1. Detector code symbols
2. Flow transmitter code symbols
3. Signal cable code symbols
4. Tag No. , as necessary
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Sales Div. III, International Sales Group
Global Business Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan