FUJI EDSX6-136H

REMOTE SEAL TYPE
DIFFERENTIAL PRESSURE TRANSMITTER
FKD...5
DATA SHEET
The FCX–AIII differential pressure transmitter accurately
measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20mA signal. The
transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology
to provide exceptional performance and functionality. Totally
welded construction of the seals assures excellent reliability
in high temperature and highly corrosive process conditions.
FEATURES
1. High accuracy
0.2% accuracy for all calibrated spans is a standard feature for all DP models covering 0.32kPa {3.2mbar} range
to 500kPa {5bar} high differential pressure range. 0.1%
accuracy is available as option. Fuji’s micro-capacitance
silicon sensor assures this accuracy for all elevated or
suppressed calibration ranges without additional adjustment.
2. Minimum environmental influence
The “Advanced Floating Cell” design which protects the
pressure sensor against changes in temperature, static
pressure, and overpressure substantially reduces total
measurement error in actual field applications.
3. Fuji/HART® bilingual communications protocol
FCX–AIII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®.
Any HART® compatible devices can communicate with
FCX–AIII.
4. Application flexibility
Various options that render the FCX–AIII suitable for almost any process applications include:
– Full range of hazardous area approvals
– Built-in RFI filter and lightning arrester
– 5-digit LCD meter with engineering unit
– Stainless steel electronics housing
– Wide selection of materials
– High temperature, high vacuum seals
5. Programmable output Linearization Function
In addition to Linear and Square Root, output signal can
be freely programmable.
(Up to 14 compensated points at approximation.)
6. Burnout current flexibility (Under Scale: 3.2 to 4.0mA,
Over Scale: 20.0 to 22.5mA)
Burnout signal level is adjustable using Model FXW
Hand Held Communicator (HHC) to comply with NAMUR
NE43.
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level as
wet calibration.
SPECIFICATIONS
Functional specifications
Service:
Liquid, gas, or vapour
Static pressure, span, and range limit:
Type
F KD
Static pressure
3
FKD
5
FKD
6
}
Up to
flange rating
Span limit [kPa]
(m bar}
Min.
Max.
0.32
{ 3.2 }
1.3
{ 13 }
5
{ 50 }
32
{ 320 }
130
{ 1300 }
500
{ 5000}
Range limit
[kPa] {m bar}
+/− 32
{+/− 320}
+/− 130
{+/− 1300}
+/− 500
{+/− 5000}
Remark : To minimize environmental influence, span should be greater
than 1/40 of the max. span in most applications.
– Lower limit of static pressure (vacuum limit),
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: Atmospheric pressure
– The maximum span of each sensor can be converted
to different units using factors as below.
1MPa =103kPa=10bar=10.19716kgf/cm2
=145.0377psi
1kPa=10mbar=101.976mmH2O=4.01463H2O
Overrange limit: To maximum static pressure limit
Output signal:
4 to 20mA DC (linear or square root) with
digital signal superimposed on the 4 to
20mA signal
Power supply:
Transmitter operates on 10.5V to 45V DC
at transmitter terminals.
10.5V to 32V DC for the units with optional
arrester.
EDSX6-136h
Date
Aug. 10, 2011
FKD...5
Load limitations: see figure below
Process:
[Ω]
Load resistance
2000
1500
R=
E-10.5
(Imax+0.9)x10-3
−20 to 120°C
H
−15 to 250°C
J
Operating
area
24V
−40 to 180°C 2.7kPa abs
−15 to 250°C {20mmHg
20 to 300°C abs}
S
T
45V
0.13kPa abs
−15 to 200°C {1mmHg abs}
or more
K
0
10
16.35
10.5V
Power voltage (DC)
Note: For communication with HHC
required.
(1)
50
E[ V ]
(Model: FXW), min. of 250 is
Hazardous locations: TABLE 2
Zero/span adjustment:
Zero and span are adjustable from the
HHC(1). Zero and span are also adjustable
externally from the adjustment screw.
Damping:
Adjustable from HHC or local configurator
unit with LCD display.
The time constant is adjustable between
0.06 to 32 seconds.
Zero elevation/suppression:
−100% to +100% of URL
Normal/reverse action:
Selectable from HHC(1)
Indication:
Analog indicator or 5-digit LCD meter, as
specified.
Burnout direction: Selectable from HHC(1)
If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale”
or “Output Underscale” modes.
“Output Hold”: Output signal is hold as the value just
before failure happens.
“Output Overscale”: Adjustable within the range 20.0mA
to 22.5mA from HHC(1)
“Output Underscale”: Adjustable within the range 3.2mA
to 4.0mA from HHC(1)
4
20
22.5 [mA]
Over scale
Burnout
Normal operating range
Under scale
Probable under range
Burnout
Probable over range
Output limits conforming to NAMUR NE43 by order.
Loop-check output:
Transmitter can be configured to provide
constant signal 3.2mA through 22.5mA
by HHC(1).
Temperature limit:
Ambient: −40 to + 85°C
(−20 to + 80°C for LCD indicator)
(−40 to + 60°C for arrester option)
(−10 to + 60°C for fluorinated oil fill transmitter)
(−10 to + 85°C for silicone oil “H”, “S”, “K”) *)
(+ 20 to + 85°C for silicone oil “J”, “T”) *)
*) In case of capillary length is more than 7m, max
temperature is +55°C.
For explosionproof units (flameproof or intrinsic safety),
ambient temperature must be within the limits specified in each standard.
Atmospheric
pressure
20 to 300°C
Y and G
250
Storage: −40 to +90°C
Humidity limit:
0 to 100% RH
Communication: With HHC(1) (Model FXW, consult Data
Sheet No. EDS8-47), following items can
be remotely displayed or configured.
Note: HHC’s version must be higher than 7.0
(or FXW
1− 4), for FCX–AIII.
Local configurator with LCD display (option):
Local confi gurator with 3 push button
and LCD display can support following
items.
Items
By communication By local configurator
with FXW
(with 3 push button)
Display
Set
Display
Set
Tag No.
v
v
v
v
Model No.
v
v
v
v
Serial No. & Software Version
v
—
v
—
Engineering unit
v
v
v
v
Range limit
v
—
v
—
Measuring range
v
v
v
v
Damping
v
v
v
v
Linear
v
v
v
v
Square root
v
v
v
v
Burnout direction
v
v
v
v
Calibration
v
v
v
v
Output adjust
—
v
—
v
Output mode
Data
v
—
v
—
Self diagnoses
v
—
v
—
Printer (In case of FXW with
printer option)
v
—
—
—
External switch lock
v
v
v
v
Transmitter display
v
v
v
v
Linearize
v
v
—
—
Rerange
v
v
v
v
Saturate current
v
v
v
v
Write protect
v
v
v
v
History
– Calibration history
– Ambient temperature history
v
v
v
—
v
v
v
—
Programmable output linearization function:
Output signal can be characterized with
“14 points linear approximation function”
from HHC(1).
EMC Conformity: EN61326-1: 2006
(Note)
2
W, A and D
Silicone oil
577Ω
Lower limit
of
static press.
Process
temperature
Fluorinated oil
1000
500
3.2
Code in the
13th digit of
“Code symbols”
Fill fluid
1474Ω
(1) HHC: Hand Held Communicator
Performance specifications
Physical specifications
Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4
to 20mA analog output in linear mode.
Accuracy rating: (including linearity, hysteresis, and repeatability)
(Standard)
For spans greater than 1/10 of URL: 0.2% of span
For spans below 1/10 of URL:
0.1  URL
± 0.1+0.1
% of span
Span
(Option) (Code; 21th digit H,K)
For spans greater than 1/10 of URL: 0.1% of span
For spans below 1/10 of URL:
0.1  URL
± 0.05+0.05
% of span
Span
Stability:
±0.2% of upper range limit (URL) for 10
years.
Temperature effect (*):
Effects per 28°C change between the
limits of −40°C and +85°C
(Standard)
Zero shift: ±0.35% of URL
Total effect: ±0.5% of URL
(Option) (Code; 21th digit J,K)
Zero shift: ±0.3% of URL
Total effect: ±0.4% of URL
(
)
(
)
Note: * Excluding effect by temperature difference
between the seals.
Static pressure effect:
Zero shift; 0.2% of URL / 1MPa
Span shift: −0.2% of calibrated span /
1MPa
Overrange effect: Zero shift; 0.1% of URL for flange rating
pressure
Supply voltage effect:
Less than 0.005% of calibrated span per
1V
Update rate:
60 msec
Step response: (without electrical damping)
Range code
Time constant (at 23°C)
“3”
2
“5”
1.7 s
“6”
1.7 s
Dead time
s
0.12 s
Dielectric strength:
500V AC, 50/60Hz 1 min., between circuit and earth.
Insulation resistance:
More than 100M at 500V DC.
Internal resistance for external field indicator:
12 or less
Electrical connections:
G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5
conduit, as specified.
Process connections:
JIS, ANSI, or DIN raised face flanges.
JIS: 10K80A, 10K100A, 30K80A, or
30K100A
ANSI: 150LB 3", 150LB 4", 300LB 3", or
300LB 4"
DIN: PN40 DN80 or PN16 DN100
See OUTLINE DIAGRAM for detailed
dimensions.
Diaphragm extension:
0, 50, 100, 150, or 200mm as specified.
(See model code. Extended diaphragm is
available only with 316L stainless steel or
Hastelloy-C diaphragm)
Process-wetted parts material:
Diaphragm: 316L stainless steel, Hastelloy-C, Monel, Tantalum, Titanium or Zirconium
Flange face: 316 stainless steel, HastelloyC lining
Monel lining, or Tantalum lining
Extension: 316 stainless steel or HastelloyC
Non-wetted parts material:
Electronics housing: Low copper die-cast
aluminum alloy finished with polyester
coating (standard), or 316 stainless
steel (ASTM CF8M), as specified.
Capillary: In case of 11th code “D, E, F, L,
M, N, P“, PE armored stainless steel.
In case of 13th code “Q, R, S, T, V, W,
X“, stainless steel armored stainless
steel.
Mounting flange: 304 stainless steel or
carbon steel
Fill fluid: Silicone oil (standard) or fluorinated oil
Mounting bracket: 304 stainless steel
Environmental protection:
IEC IP67 and NEMA 6/6P
Mounting:
On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting
Mass {weight}:
Transmitter approximately 12 to 31kg
without options.
Add; 0.5kg for mounting bracket
4.5kg for stainless steel housing
option
1.5kg per 50mm extension of diaphragm
3
FKD...5
Silicone (Code Y,G)
[kPa abs]
{mbar abs}
Silicone (Code S)
[kPa abs]
{mbar abs}
Silicone (Code T)
Sealing liquid:Silicone (Code K)
101
{1010}
53.3
{533}
Operating area
Operating pressure
Operating pressure
101
{1010}
13.3
{133}
−40 −15
20 60 85 120
180
Process temperature [°C]
230 250
300
Fig. 1 Relation between process temperature and
operating pressure
Optional features
A plug-in analog indicator (2.5% accuracy).
An optional 5-digit LCD meter with engineering unit is also available.
Local configurator with LCD display:
An optional 5 digits LCD meter with 3
push buttons can support items as using
communication with FXW.
Arrester:
A built-in arrester protects the electronics
from lightning surges.
Lightning surge immunity:
4kV (1.2 × 50µs)
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all
process wetted parts oil-free.
The fill fluid is fluorinated oil.
Chlorine service: Oil-free procedures as above. Includes
fluorinated oil for fill.
Degreasing:
Process-wetted parts are cleaned, but the
fill fluid is standard silicone oil. Not for use
on oxygen or chlorine measurement.
Vacuum service: Special silicone oil and filling procedure
are applied.
See Fig. 1, Fig. 2.
Optional tag plate:
An extra stainless steel tag for customer
tag data is wired to the transmitter.
Coating of cell: Cell s surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive.
4
Non-operating
area
0.27
{2.7}
0.13
{1.3}
2.7
{27}
Indicator:
Operating area
−15
100
Process temperature [°C]
200
Fig. 2 Relation between process temperature and
operating pressure
ACCESSORIES
Hand-held communicator:
(Model FXW, refer to Data Sheet No.
EDS 8-47)
CODE SYMBOLS
1 2 3 4 5 6 7 8
Digit
4
5
6
7
Description
<Connections>
<Conduit connection>
<Case type>
G1/2
T type
1/2-14NPT
T type
Pg 13.5
T type
M20 × 1.5
T type
G1/2
L type
1/2-14NPT
L type
Pg 13.5
L type
M20 × 1.5
L type
<Flange>
Mounting flange
Flange size and rating
304 stainless
JIS 10K 80A
steel
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN16/40 DN80
DIN PN16 DN100
JIS 20K 80A
ANSI/JPI 600LB 3B
Carbon steel
JIS 10K 80A
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN16/40 DN80
DIN PN16 DN100
316 stainless
JIS 10K 80A
steel
ANSI/JPI 150LB 3B
ANSI/JPI 150LB 4B
ANSI/JPI 300LB 3B
ANSI/JPI 300LB 4B
ANSI/JPI 600LB 3B
None
3 inch wafer
(wafer type)
4 inch wafer
<Span limit (*1) [kPa]{m bar}>
0.32.... 32
{3.2..... 320}
1.3...... 130
{13...... 1300}
5......... 500
{50...... 5000}
<Material/diaphragm extension>
Flange face
Diaph. extension [mm]
Diaphragm
316 stainless
0
316L stainless
steel
50
steel
100
(*2)
150
200
Hastelloy-C
0
Hastelloy-C
316 stainless steel
0
316L stainless
+Au coating
316 stainless steel
0
Hastelloy-C
Monel
0
Monel
Tantalum
0
Tantalum
Titanium
0
Titanium
(*3)
Zirconium
0
Zirconium
8
Note 1: (*1)
Note 2: (*2)
Note 3: (*3)
Note
F KD
9 10 11 12 13
14 15
5
0
21
Digit No.
of code
5
6
7
8
S
T
V
W
0
1
2
3
4
5
6
7
8
9
M
R
A
B
C
D
E
F
G
H
J
K
S
T
U
V
W
X
P
Q
Note 1
3
5
6
Note 2
Note 3
V
A
B
C
D
H
J
W
M
T
P
R
5
100: 1 turn down is possible, but should be used at a span greater than
1/40 of the maximum span for better performance.
Available for 5th digit
code "1", "3", "5", "7", "B", "D", "F", "H", "K", "Q", "U", "W", when 13th digit code "S", "T", "K".
Available for 6th code "5", "6" and 5th code "0", "2", "4", "6", "8", "A", "C", "E", "G", "J", "P", "M", "R", "S", "T", "W".
5
FKD...5
1 2 3 4 5 6 7 8
Description
Digit
<Indicator and arrester>
9
Indicator
Arrester
None
None
Analog, 0 to 100% linear scale
None
Analog, 0 to 100% sq. root scale (*7)
None
Analog, custom scale
None
Analog, double scale (linear and sq. root)
None
None
Yes
Analog, 0 to 100% linear scale
Yes
Analog, 0 to 100% sq. root scale (*7)
Yes
Analog, custom scale
Yes
Analog, double scale (linear and sq. root)
Yes
Digital, 0 to 100% linear scale
None
Digital, custom scale
None
Digital, 0 to 100% square root scale
None
Digital, 0 to 100% linear scale
Yes
Digital, custom scale
Yes
Digital, 0 to 100% square root scale
Yes
Digital, 0 to 100% linear scale
(Local configurator unit with LCD display)
None
Digital, custom scale
(Local configurator unit with LCD display)
None
Digital, 0 to 100% square root scale
(Local configurator unit with LCD display)
None
Digital, 0 to 100% linear scale
(Local configurator unit with LCD display)
Yes
Digital, custom scale
(Local configurator unit with LCD display)
Yes
Digital, 0 to 100% square root scale
(Local configurator unit with LCD display)
Yes
<Approvals for hazardous locations>
10
None (for ordinary locations)
TIIS, Flameproof (Cable gland seal) (*11)
TIIS, Intrinsic safety
FM, Flameproof (or explosionproof) (*14)
FM, Intrinsic safety and nonincentive
FM Combined of flameproof and intrinsic safety (*14)
ATEX Flameproof (*13)
ATEX Intrinsic safety
ATEX Type n
ATEX Combined of flameproof and intrinsic safety (*13)
IECEx Scheme, Flameproof (*13)
IECEx Scheme, Intrinsic safety
CSA, Flameproof (or explosionproof) (*14)
CSA, Intrinsic safety and nonincentive
NEPSI, Flameproof (or exprosionproof)
NEPSI, Intrinsic safety
NEPSI, Combined of flameproof and intrinsic safety
<Capillary and mounting bracket>
11
Capillary
Mounting bracket
armor of capilary
1.5 m
304 Stainless steel
PE
3
304 Stainless steel
PE
5
304 Stainless steel
PE
6
304 Stainless steel
PE
7
304 Stainless steel
PE
8
304 Stainless steel
PE
10
304 Stainless steel
PE
1.5
304 Stainless steel
Stainless steel
3
304 Stainless steel
Stainless steel
5
304 Stainless steel
Stainless steel
6
304 Stainless steel
Stainless steel
7
304 Stainless steel
Stainless steel
8
304 Stainless steel
Stainless steel
10
304 Stainless steel
Stainless steel
<Options>
12
Extra SS tag plate
Stainless steel elec. housing
None
None
Yes
None
None (*6)
None
Yes
None
None
Yes
(*8)
Yes
Yes
Note 4: (*4)
Note 5:
Note 6:
Note 7:
Note 8:
6
(*5)
(*6)
(*7)
(*8)
Note
Note 7
Note 7
F KD
9 10 11 12 13
5
14 15
21
0
A
B
C
D
J
E
F
G
H
K
L
P
M
Q
S
N
1
2
3
4
5
6
Note 11
Note 14
Note 14
Note 13
Note 13
Note 13
Note 14
(*4)
(*4)
(*4)
(*4)
(*4)
(*4)
(*4)
(*5)
(*5)
(*5)
(*5)
(*5)
(*5)
(*5)
Coating of cell
None
None
Yes
Yes
Yes
Yes
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
Note 4
Note 5
Note 5
Note 5
Note 5
Note 5
Note 5
Note 5
Note 6
Note 8
Note 8
A
C
G
D
H
V
X
K
P
M
R
T
E
J
F
S
U
D
E
L
F
M
N
P
Q
R
S
T
V
W
X
Y
B
M
N
P
Q
Available for 13th digit code "Y, W, G, A, D".
Inquire about in case of 13th other code.
Available for all 13th digit code.
Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes".
In case of squre root output mode, squre root scale is not available.
Not available for 10th digit code "C".
Digit No.
of code
1 2 3 4 5 6 7 8
Note
Description
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service
Fluorinated oil (7th digit code "V", "W", "A", "B", "C" and "D")
Chlorine service
Fluorinated oil (7th digit code "H", "T")
High temp. 250°C
Silicone oil 7th digit code "V", "W", "A", "B", "C",
High temp. 300°C
Silicone oil "D", "H", "F", "G", "K", and "L"
(*9)
High temp. and vacuum (250°C) Silicone oil 7th digit code "V", "W", "A", "B", "C",
Note 9
High temp. and vacuum (300°C) Silicone oil and "D"
High temp. and high vacuum Silicone oil
<Teflon membrane>
14
None
Yes (Available for 5th digit code "0", "2", "4", "6", "8", "A", "C", "E", "G", "J", "P",
"M", "R", "S", "T", "V", "X" and 7th digit code "V", "W", "J".
Not available for the 13th digit code "H", "J".)
<Other options> (*10)
Note 10
21
High accuracy type
Instruction manual attached
Low temperature effect type
Instruction manual attached
H+J
Instruction manual attached
Instruction manual unattached
High accuracy type
Instruction manual unattached
Low temperature effect type
Instruction manual unattached
T+U
Instruction manual unattached
Note 9: (*9)
Treatment; Standard
Note 10: (*10) If other option is not necessary, 21st digit code is blank.
In case of 21st digit code is blank, instruction manual attached.
Note 11: (*11) Available for 4th digit code "S".
Note 13: (*13) Available for 4th digit code "6", "8", "T", "W".
Note 14: (*14) Available for 4th digit code "6", "T".
Digit
13
F KD
9 10 11 12 13
14 15
5
21
0
Digit No.
of code
Y
W
G
A
D
H
J
S
T
K
Y
C
H
J
K
L
T
U
V
7
FKD...5
ORDERING INFORMATION
When ordering this instrument, specify:
1. CODE SYMBOLS
2. Measuring range
3. Output orientation (burnout direction) when abnormality
is occurred in the transmitter.
Hold / Overscale / Underscale
Unless otherwise specified, output hold function is supplied.
4. Output mode (linear or square root output)
Unless otherwise specified, output mode is linear.
5. Indication method (indicated value and unit) in case of
the actual scale (code D, H, P, S ,2 ,5 on 9th digit).
6. Tag No. (up to 14 alphanumerical characters), if required.
8
OUTLINE DIAGRAM (Unit:mm)
<AMP. case: L type>
IN CASE OF 4TH DIGIT CODE "S,V,W"
MTG. PIPE JIS 50A (2B)
IN CASE OF 4TH DIGIT CODE "T"
φ81
103
103
φ81
8
10
ZERO ADJ. SCREW
38
U-BOLT M8
57
"B" CONDUIT CONN.
37
(21)
(11)
195
WITH ANALOG IND.
4 HOLES 9 DIA.
N HOLES h DIA
WITH DIGITAL IND.
φ
E
P
φH±1
φF
φG
φE
φD
INNER OF GASKET
FLANGE
242
20
L
t
41
126
43
EARTH TERMINAL
221
DETAIL "B"
(CONDUIT CONN.)
K
M
φ15
2-M8X12
S
J
SEE TABLE1
62
70
120
L.P.
MASS.APPROX(kg)
V, W, J, H, M, T, P, R
A
B
C
D
0
50
100
150
200
S
T
V
W
12.7∼18.2
13.7∼29.2
14.2∼29.7
14.7∼30.2
15.2∼30.7
INNER OF GASKET
φF
TABLE 1
5th digit of the
code symbols
φD
0, A, S
M
2, C
1, B
3, D
4, E, T
6, G, V
R, X
5, F, U
7, H, W
8, J
9, K
185
200
210
210
240
191
210
210
229
254
200
220
φF
CorrosionStandard
resistant
materials
materials
specification specification
φE
Note 1
Note 2
126
134
150
126
134
160
126
134
170
151
158
175
151
158
195
126
134
152.5
126
134
168
126
134
168
151
158
190.5
151
158
200
126
134
160
180
151
158
φG φH±1
100
100
100
103
103
100
100
100
103
103
100
103
73
73
73
96
96
73
73
73
96
96
73
96
t
P
N-φh
FLANGE
38
42
48
38
52
44
49
52
44
52
44
40
116
116
116
141
141
116
116
116
141
141
116
141
8-19
8-23
8-23
8-19
8-25
4-20
8-23
8-23
8-20
8-23
8-18
8-18
JIS-10K-80A
JIS-20K-80A
JIS-30K-80A
JIS-10K-100A
JIS-30K-100A
ANSI 150LB 3B
ANSI 300LB 3B
ANSI 600LB 3B
ANSI 150LB 4B
ANSI 300LB 4B
DIN PN40 DN80
DIN PN16 DN100
Note1) In case of the 7th digit of type code is V, A, B, C, D, J or W.
Note2) In case of the 7th digit of type code is H, M, T, P or R.
CONNECTION DIAGRAM
<SS TAG PLATE>
2-M6 SCREW
DEPTH 9
Q
L
J
K
M
G 1/2
18
2
1/2-14NPT 16
4
Pg13.5
10.5 4.5
M20×1.5
16
4
4th digit of the
code symbols
H.P.
φG
Conduit conn.
7th digit of the
code symbols
20
<WAFER TYPE>
11th digit of the
code symbols
S(m)
D, Q
E, R
L, S
F, T
M, V
N, W
P, X
1.5
3
5
6
7
8
10
Q
116
141
OPTION PARTS FOR FLAMEPROOF OF TIIS (JAPAN)
10th digit code C (Cable gland type)
NOTE1)
G1/2
DETAIL C
φ33.5
φ13
−/CK− CK+
75
19
106
20
17
+
80A, 3B
100A, 4B
"C" CONDUIT CONN.
G1/2
CABLE GLAND
NOTE1) IN CASE OF 10TH CODE“C”
, φ11 CABLE IS SUITBLE.
9
FKD...5
<AMP. case: T type>
WITH ANALOG IND.
IN CASE OF 4TH DIGIT CODE "5,7,8"
MTG. PIPE JIS 50A (2B)
10
IN CASE OF 4TH DIGIT CODE "6"
57
φ81
ZERO ADJ. SCREW
100
100
38
U-BOLT M8
(21)
(11)
8
EARTH TERMINAL
WITH DIGITAL IND.
"B" CONDUIT CONN.
37
208
N HOLES h DIA
φ
E
P
φH±1
φF
φG
INNER OF GASKET
φE
φD
4 HOLES 9 DIA.
FLANGE
242
127
20
20
L
t
248
DETAIL "B"
(CONDUIT CONN.)
K
M
φ15
J
2-M8X12
SEE TABLE1
S
L.P.
5
6
7
8
L
MASS.APPROX(kg)
J
K
M
G 1/2
18
2
1/2-14NPT 16
4
Pg13.5
10.5 4.5
M20×1.5
16
4
V, W, J, H, M, T, P, R
A
B
C
D
0
50
100
150
200
12.7∼18.2
13.7∼29.2
14.2∼29.7
14.7∼30.2
15.2∼30.7
INNER OF GASKET
5th digit of the
code symbols
φD
0, A, S
M
2, C
1, B
3, D
4, E, T
6, G, V
R, X
5, F, U
7, H, W
8, J
9, K
185
200
210
210
240
191
210
210
229
254
200
220
φF
TABLE 1
φF
CorrosionStandard
resistant
materials
materials
specification specification
φE
Note 1
Note 2
126
134
150
126
134
160
126
134
170
151
158
175
151
158
195
126
134
152.5
126
134
168
126
134
168
151
158
190.5
151
158
200
126
134
160
180
151
158
φG φH±1
100
100
100
103
103
100
100
100
103
103
100
103
73
73
73
96
96
73
73
73
96
96
73
96
t
P
N-φh
FLANGE
38
42
48
38
52
44
49
52
44
52
44
40
116
116
116
141
141
116
116
116
141
141
116
141
8-19
8-23
8-23
8-19
8-25
4-20
8-23
8-23
8-20
8-23
8-18
8-18
JIS-10K-80A
JIS-20K-80A
JIS-30K-80A
JIS-10K-100A
JIS-30K-100A
ANSI 150LB 3B
ANSI 300LB 3B
ANSI 600LB 3B
ANSI 150LB 4B
ANSI 300LB 4B
DIN PN40 DN80
DIN PN16 DN100
Note1) In case of the 7th digit of type code is V, A, B, C, D, J or W.
Note2) In case of the 7th digit of type code is H, M, T, P or R.
CONNECTION DIAGRAM
−/CK− CK+
75
+
<SS TAG PLATE>
20
10
H.P.
2-M6 SCREW
DEPTH 9
Q
7th digit of the
code symbols
φG
Conduit conn.
4th digit of the
code symbols
62
70
120
20
<WAFER TYPE>
11th digit of the
code symbols
S(m)
D, Q
E, R
L, S
F, T
M, V
N, W
P, X
1.5
3
5
6
7
8
10
80A, 3B
100A, 4B
Q
116
141
TABLE 2
Authorities
ATEX
Intrinsic safety
Authorities
Ex II 1 G
Ex ia IIC T5 Tamb = –40°C to +50°C
Ex ia IIC T4 Tamb = –40°C to +70°C
Entity Parameters:
Ui=28V, Ii=94.3mA, Pi=0.66W,
Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator),
Ci=36nF (With Arrester), Li=0.7mH (With analog indicator)
Factory
Mutual
13th digit
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
W,A,D
Tamb
Factory
Mutual
Class I
Div.1 Groups B, C, D
T6 Type 4X
Class II III
Div.1 Groups E, F, G
T6 Type 4X
Tamb max = +60°C
CSA
Class I
Div.1 Groups C, D
Class II
Div.1 Groups E, F, G
Class III
Div.1
Note) “Seal Not Required” enclosure is allowed.
Class I
Div.1 Groups A, B, C, D
Class II
Div.1 Groups E, F, G
Class III
Div.1
Temp Code T5
Tamb max = +50°C
Temp Code T4
Tamb max = +70°C
Entity Parameters:
Vmax=28V, Imax=94.3mA, Ci=25nF (Without Arrester),
Ci=36nF (With Arrester),Li=0.6mH (Without analog meter),
Li=0.7mH (With analog meter)
TIIS
Ex ia IIC T4
Tamb max = +60°C
Entity Parameters:
Ui=28V, Ii=94.3mA, Pi=0.66W,
Ci=38.4nF, Li=0.694mH
IECEx
Scheme
Ex ia IIC T4
Tamb = –40°C to +70°C
Ex ia IIC T5
Tamb = –40°C to +50°C
Entity Parameters:
Ui=28V, Ii=94.3mA, Pi=0.66W,
Ci=26nF (Without Arrester), Li=0.6mH (Without analog indicator),
Ci=36nF (With Arrester), Li=0.7mH (With analog indicator)
NEPSI
Ex II 2 GD
Ex d IIC T6 IP66/67 T85°C
Tamb = −40°C to +65°C
Ex d IIC T5 IP66/67 T100°C
Tamb = −40°C to +85°C
−40°C to +85°C
−20°C to +80°C
−20°C to +60°C
−40°C to +60°C
−10°C to +60°C
Entity Parameters:
Vmax=28V, Imax=94.3mA, Pi=0.66W,
Ci=35.98nF, Li=0.694mH
CSA
ATEX
Class I II III
Div.1 Groups A, B, C, D, E, F, G
T4 Entity Type 4X
Model code
9th digit
A,B,C,D,J
L,P,M,1,2,3
Q,S,N,4,5,6
E,F,G,H,K
−
TIIS
Ex do IIB+H2 T4
Tamb max = +60°C
Maximum process temp. = +120°C
IECEx
Scheme
Ex d IIC T5 IP66/67
Tamb = −40°C to +85°C
Ex d IIC T6 IP66/67
Tamb = −40°C to +65°C
NEPSI
Ex d IIB+H2 T6
Tamb = −40°C to +60°C
13th digit
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
W,A,D
ATEX
Ex II 3 GD
EEx nL IIC T5 Tamb = −40°C to +50°C
EEx nL IIC T4 Tamb = −40°C to +70°C
Specific Parameters:
Model without arrester:
Ui=42.4V, Ii=113mA, Pi=1W,
Ci=25.18nF, Li=0.694mH
Model with arrester:
Ui=32V, Ii=113mA, Pi=1W,
Ci=35.98nF, Li=0.694mH
EEx nAL IIC T5 Tamb = −40°C to +50°C
EEx nAL IIC T4 Tamb = −40°C to +70°C
Specific Parameters:
Model without arrester:
Umax=42.4V, Imax=113mA, Pmax=1W
Model with arrester:
Umax=32V, Imax=113mA, Pmax=1W
Tamb
−40°C to +85°C
−20°C to +80°C
−20°C to +60°C
−40°C to +60°C
−10°C to +60°C
Type n
Nonincendive
Authorities
Ex ia IIC T4
Ex d IIB+H2 T6 / Ex ia IIC T4
Model code
9th digit
A,B,C,D,J
L,P,M,1,2,3
Q,S,N,4,5,6
E,F,G,H,K
−
Flameproof
Factory
Mutual
(pending)
Class I II III
Div.2 Groups A, B, C, D, F, G
T4 Entity Type 4X
Model code
9th digit
A,B,C,D,J
L,P,M,1,2,3
Q,S,N,4,5,6
E,F,G,H,K
−
Entity Parameters:
Ui=42.4V, Ii=113mA, Pi=1W,
Ci=35.98nF, Li=0.694mH
CSA
13th digit
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
W,A,D
Tamb
−40°C to +85°C
−20°C to +80°C
−20°C to +60°C
−40°C to +60°C
−10°C to +60°C
Class I
Div.2 Groups A, B, C, D
Class II
Div.2 Groups E, F, G
Class III
Div.2
Temp Code T5
Tamb max = +50°C
Temp Code T4
Tamb max = +70°C
Entity Parameters:
Vmax=28V, Ci=25.18nF (Without Arrester),
Ci=35.98nF (With Arrester), Li=0.694mH
11
FKD...5
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/
Information in this catalog is subject to change without notice.
Printed in Japan