FUJI PG985C6R

http://www.fujisemi.com
PG985C6R (600V, 20A)
FUJI Diode
Super LLD III (For CCM-PFC)
Low Loss Super Hight Speed Rectifier
Outline Drawings [mm]
Features
Connection diagram
TO-3PF
• Lower power loss by higher switching speed
and also lower VF than conventional type
• Soft recovery and low noise
PG985C6
PG985C6
Applications
• PFC circuit (current continuous mode)
Maximum Ratings and Characteristics
Maximum ratings (at Ta=25˚C Unless otherwise specified)
Item
Symbols
Repetitive peak reverse voltage
VRRM
Isolating voltage
Viso
Conditions
Terminals-to-case, AC.1min
Ratings
Units
600
V
1500
V
20 *
A
IO
Square wave duty =1/2
Tc =47˚C, 50Hz
Non-repetitive surge current **
I FSM
Sine wave, 10ms 1shot
50
A
Operating junction temperature
Tj
150
˚C
Storage temperature
Tstg
-40 to +150
˚C
Maximum
Units
Average output current
*Out put current of center tap full wave connection.
**Rating per element
Electrical characteristics (at Ta=25˚C Unless otherwise specified)
Item
Symbols
Conditions
Forward voltage***
VF
IF = 10A
3
V
Reverse current***
IR
VR =VRRM
30
µA
Reverse recovery time***
trr
IF = 0.1A, IR = 0.2A,
Irec = 0.05A
0.028
µs
Rth(j-c)
Junction to case
2
˚C/W
Conditions
Ratings
Units
Recommended torque
0.4 to 0.6
N•m
6.0
g
Thermal resistance
***Rating per element
Mechanical characteristics
Item
Mounting torque
Approximate mass
1
PG985C6R (600V, 20A)
FUJI Diode
http://www.fujisemi.com
Forward Characteristic (typ.)
Reverse Characteristic (typ.)
Tj=150°C
Tj=125°C
10
IR Reverse Current (µA)
Tj=100°C
Tj=100°C
Tj=25°C
1
Tj=25°C
0.1
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
VR Reverse Voltage (V)
VF Forward Voltage (V)
Forward Power Dissipation (max.)
Reverse Power Dissipation (max.)
35
0.035
DC
360
360
30
0.030
VR
I0
25
(W)
0.025
Reverse Power Dissipation
Square wave λ=60°
20
Square wave λ=120°
Sine wave λ=180°
Square wave λ=180°
15
PR
IF Forward Current (A)
Tj=150°C
Tj=125°C
10
5
0.020
α=180°
0.015
0.010
0.005
Per 1element
0
0.000
0
2
4
6
IF(AV) Average Forward Current
8
10
0
(A)
100
200
VR
2
300
400
Reverse Voltage
500
(V)
600
700
PG985C6R (600V, 20A)
FUJI Diode
http://www.fujisemi.com
Junction Capacitance Characteristic (typ.)
Current Derating (Io-Tc) (max.)
1000
160
150
140
130
120
110
100
Junction Capacitance (pF)
90
80
70
60
DC
Cj
Tc
Case Temperature
(°C)
100
50
Square wave λ=180°
Sine wave λ=180°
Square wave λ=120°
40
10
30
20
Square wave λ=60°
10
0
0
2
4
6
8
10
12
14
16
18
20
Io Average Output Current
22
24
26
28
1
1
(A)
λ:Conduction angle of forward current for each rectifier element
Io:Output current of center-tap full wave connection
Surge Capability (max.)
100
IFSM
Peak Half - Wave Current
(A)
1000
10
1
1
10
100
Number of Cycles at 50Hz
3
10
100
VR
Reverse Voltage (V)
1000
PG985C6R (600V, 20A)
FUJI Diode
http://www.fujisemi.com
Transient Thermal Impedance (max.)
2
Transient Thermal Impedance
(°C/W)
10
1
10
0
10
-1
10
-3
10
-2
10
-1
0
10
10
t
Time
(sec)
4
1
10
2
10
PG985C6R (600V, 20A)
FUJI Diode
http://www.fujisemi.com
WARNING
1. This Catalog contains the product specifications, characteristics, data, materials, and structures as of March 2010.
The contents are subject to change without notice for specification changes or other reasons. When using a product listed in this
Catalog, be sure to obtain the latest specifications.
2. A
ll applications described in this Catalog exemplify the use of Fuji's products for your reference only. No right or license, either
express or implied, under any patent, copyright, trade secret or other intellectual property right owned by Fuji Electric Systems Co., Ltd.
is (or shall be deemed) granted. Fuji Electric Systems Co., Ltd. makes no representation or
warranty, whether express or implied, relating to the infringement or alleged infringement of other's intellectual property rights which
may arise from the use of the applications described herein.
3. A lthough Fuji Electric Systems Co., Ltd. is enhancing product quality and reliability, a small percentage of semiconductor
products may become faulty. When using Fuji Electric semiconductor products in your equipment, you are requested to take
adequate safety measures to prevent the equipment from causing a physical injury, fire, or other problem if any of the products
become faulty. It is recommended to make your design fail-safe, flame retardant, and free of malfunction.
4. T
he products introduced in this Catalog are intended for use in the following electronic and electrical equipment which has
normal reliability requirements.
• Computers
• OA equipment
• Communications equipment (terminal devices)
• Measurement equipment
• Machine tools
• Audiovisual equipment
• Electrical home appliances
• Personal equipment
• Industrial robots etc.
5. If you need to use a product in this Catalog for equipment requiring higher reliability than normal, such as for the equipment listed
below, it is imperative to contact Fuji Electric Systems Co., Ltd. to obtain prior approval. When using these products for
such equipment, take adequate measures such as a backup system to prevent the equipment from malfunctioning even if a Fuji's
product incorporated in the equipment becomes faulty.
• Transportation equipment (mounted on cars and ships)
• Trunk communications equipment
• Traffic-signal control equipment
• Gas leakage detectors with an auto-shut-off feature
• Emergency equipment for responding to disasters and anti-burglary devices • Safety devices
• Medical equipment
6. Do not use products in this Catalog for the equipment requiring strict reliability such as the following and equivalents to strategic
equipment (without limitation).
• Space equipment
• Aeronautic equipment
• Nuclear control equipment
• Submarine repeater equipment
7. Copyright ©1996-2008 by Fuji Electric Systems Co., Ltd. All rights reserved.
No part of this Catalog may be reproduced in any form or by any means without the express permission of Fuji Electric Systems Co., Ltd.
8. If you have any question about any portion in this Catalog, ask Fuji Electric Systems Co., Ltd. or its sales agents before
using the product.
Neither Fuji Electric Systems Co., Ltd. nor its agents shall be liable for any injury caused by any use of the products not in
accordance with instructions set forth herein.
5