D E S C R I P T I O N
The Sentinel is a powerful multi-point level switch. The
microprocessor-based circuitry has non-volatile memory,
to protect against data loss. Powerful diagnostics check
all major aspects of the system while MagneCal™ offers
the user the advantage that one small level change is
needed to calibrate.
F E A T U R E S
• Optional intrinsically safe probe circuitry (with
on-board barriers) allows safe use, even with bare
probes in hazardous media
• Intrinsically safe remote mount models up to
800 feet (240 meters) of cable
• Integral or standard remote mount up to
2500 feet (760 meters) for application flexibility
• Two to four DPDT relays yield wide application
flexibility for most alarm and control operation
• Relays 2 and 3, Series 832/842 models, may be used
for lead/lag pump sequencing
• Time delay eliminates relay chatter due to turbulence.
A P P L I C A T I O N S
• Hydrocarbons and solvents
• Usable with all Kotron probes for excellent application
flexibility
• Corrosives
• 3-button/4-digit LED data entry of all parameters
• High temperature/pressure liquids
• One small level change (2% of span) needed for initial
calibration in most cases
• Multi-point alarm/control
• Pump control
• Powerful self-diagnostics check the system, minimizing
the need for routine maintenance checks
• Lead/Lag pump control
• Diagnostics check the integrity of the probe
• Process temperatures up to +1000° F
• One relay may be dedicated as a diagnostic alarm
• Process pressures up to 5000 psig
T E C H N O L O G Y
The amount of capacitance developed in any vessel is
determined by the size (surface area) of the probe, the
distance from the probe to its ground reference, and the
dielectric constant of the medium being measured.
Considering that the probe’s mounting position is fixed
and the dielectric of the medium is constant, then the
amount of capacitance developed in any vessel becomes
dependent upon the amount of the probe which is
covered by the media.
As the media rises and falls in the tank, the amount of
capacitance developed between the probe and the
ground reference also changes. The capacitance signal is
converted to a frequency proportional to the change in
level. The amplifier then converts this digital signal into
an isolated 4–20 mA analog output signal.
S P E C I F I C A T I O N S
Supply voltage
120 VAC, 50/60 Hz (+10/-15%)
240 VAC, 50/60 Hz (+10/-15%)
24 VDC (±10%)
15 VA nominal
99% non-condensing (electronics)
Per IEC specification 801-2
70 ms to approximately 2 seconds, depending upon probe
capacitance and averaging value
-40° to +160° F (-40° to +70° C)
±0.01%/degree F (±0.018%/degree C)
Power consumption
Humidity
Electrostatic discharge protection
Response time
Ambient temperature
Temperature coefficient of set point
Maximum remote mount distance:
Standard
Intrinsically safe
2500 feet (760 meters)
800 feet (240 meters)
Data:
Entry
Indication
3-button keypad
4-digit LED, 1 overflow LED for +10,000
Relays 2 to 4 DPDT:
AC
DC
Set point range
Differential range
Time delay
2
10 amp @ 120/240 VAC resistive
10 amp @ 30 VDC resistive, 0.5 amp @ 125 VDC resistive
0–50,000 pF
0.50 pF minimum / 50,000 pF maximum
0–90 seconds level rising, falling, both
T Y P I C A L
A P P L I C A T I O N
The following sump application displays the
extraordinary power and simplified calibration
of the Kotron Sentinel with MagneCal. To better
understand how this calibration is achieved,
consider the approach in two steps:
High
level
alarm
Pump
#2
Probe can be calibrated
in one level change and
level movement as little
as 2% of tank height
Pump
#1
Low
level
alarm
Step 1
Probe calibration
Step 2
Relay configuration
All RF Capacitance devices must be calibrated in the
process vessel. To calibrate, the process level must be
varied to achieve a capacitance change.
The relays are now configured with no further level
change required.
With MagneCal, the probe is calibrated by establishing
only two reference points and storing the data in the
microprocessor, via the 4-digit LED and 3-button keypad.
With conventional electronics, the level would need to be
varied multiple times.
The Sentinel draws upon the reference data stored during
the probe calibration.
The relay control points are easily entered via the same
4-digit LED and 3-button keypad. All relays can be calibrated and recalibrated without further level change.
Relays can be set up for lead/lag operation to enable
even pump wear.
3
A G E N C Y
A P P R O V A L S
Agency
Approved Model
Protection Method
Area Classification
FM
8X2-1X02-G0X
8X2-1X03-G0X
with rigid insulated probe
Explosion proof
Class I Div. 1, Groups C & D
Class II Div. 1, Groups E, F & G
NEMA 4X, IP65
8X2-1X05-G0X
8X2-1X06-G0X
Explosion proof
with intrinsically safe
probe circuit
Electronics:
Class I Div. 1, Groups C & D
Class II Div. 1, Groups E, F & G
NEMA 4X, IP65
Probe:
Class I, II, III, Div. 1,
Groups A, B, C, D, E, F & G
NEMA 4X, IP65
8X2-1X02-R0X
8X2-1X03-R0X
8X2-1X03-Y0X
with rigid insulated probe
Explosion proof
Class I Div. 1, Groups B, C & D
Class II Div. 1, Groups E, F & G
NEMA 4X, IP65
8X2-1X05-R0X
8X2-1X06-R0X
8X2-1X06-Y0X
Explosion proof
with intrinsically safe
probe circuit
Electronics:
Class I, Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F & G
NEMA 4X, IP65
Probe:
Class I, II, III, Div. 1,
Groups A, B, C, D, E, F & G
NEMA 4X, IP65
CSA
8X2-1X00-C00
8X2-1X01-C00
Non-hazardous
TYPE 4X
8X2-1X02-G0X
8X2-1X03-G0X
with rigid insulated probe
Explosion proof
Class I Div. 1, Groups C & D
Class II Div. 1, Groups E, F & G
TYPE 4X
8X2-1X05-G0X
8X2-1X06-G0X
Explosion proof
with intrinsically safe
probe circuit
Electronics:
Class I Div. 1, Groups C & D
Class II Div. 1, Groups E, F, G
TYPE 4X
Probe:
Class I, II, III, Div. 1,
Groups A, B, C, D, E, F & G
TYPE 4X
8X2-1X02-R0X
8X2-1X03-R0X
8X2-1X03-Y0X
with rigid insulated probe
Explosion proof
Class I Div. 1, Groups B, C & D
Class II Div. 1, Groups E, F & G
TYPE 4X
8X2-1XX5-R0X
8X2-1XX6-R0X
8X2-1XX6-Y0X
Explosion proof
with intrinsically safe
probe circuit
Electronics:
Class I Div. 1, Groups B, C & D
Class II Div. 1, Groups E, F, G
TYPE 4X
Probe:
Class I, II, III, Div. 1,
Groups A, B, C, D, E, F & G
TYPE 4X
4
M O D E L
N U M B E R
Models available for quick shipment, usually within one week after factory receipt of a
complete purchase order, through the Expedite Ship Plan (ESP).
Note: Delivery is ESP only if the Model 822, 832, or 842 and probe selected are both ESP.
Refer to bulletin 50-125 for probe selections.
RELAYS
2
3
4
Relays
3 Relays (lead/lag)
4 Relays (lead/lag)
INPUT POWER
0
1
2
120 VAC
240 VAC
24 VDC
MOUNTING
0
Integral NEMA 4X
1
Remote NEMA 4X
2
Integral NEMA 4X/7/9
3
Remote NEMA 4X/7/9
5
6
Integral NEMA 4X/7/9 with intrinsically safe probe circuit
Remote NEMA 4X/7/9 with intrinsically safe probe circuit
HOUSINGS
C
NEMA 4X, aluminum base with carbon steel cover,
3
⁄4" NPT single conduit
G
NEMA 4X/7/9, cast iron, 1" NPT single conduit
R
NEMA 4X/7/9, aluminum, 1" NPT dual conduit
NEMA 4X/7/9, aluminum, 1" NPT dual conduit with 316 SS
3
⁄4" NPT single conduit (remote mount only)
Y
PROBE SELECTION
0
1
2
Probe ordered separately
18" (457 mm) guarded probe
36" (914 mm) guarded probe
P R O B E S
A full range of rigid and flexible probes for conductive and non-conductive process media is
available in various lengths and materials of
construction. For further information on probe
assemblies, refer to bulletin 50-125.
R E M O T E
8
2
1
0
0
C A B L E
Remote cable should be shielded, twisted pair,
22-gauge stranded conductors and may be
ordered using Magnetrol® part number
009-7146-001. Cable length in feet must be
specified at time of order; 2500 feet (760 m)
maximum; 800 feet (240 m) maximum for
intrinsically safe models.
5
D I M E N S I O N A L
I N C H E S
1 Rotation
clearance
S P E C I F I C A T I O N S
( m m )
4.63
(118) Dia.
B
B
1 Rotation clearance
A
3.00
(76)
A
2.75
(70)
E
C
3.75
(95)
3/4" NPT
G
G
Optional
mounting
flange
3.23
(82)
2.37
(60)
D
2 Holes
.38 (10) Dia.
3.00
(76)
2.00
(51)
2
2
F
1/2" NPT
or 3/4" NPT
3.50
(89)
IL
3
IL
.50 (13)
.625 (16)
.50 (13)
.625 (16)
Integral Mount with Standard Rigid Probe
(shown with carbon steel housing)
Remote Mount with Standard Rigid Probe
(shown with carbon steel housing)
B
Clearance
4.63
(118) Dia.
B
1 Rotation
1 Rotation clearance
A
A
3.00
(76)
2.75
(70)
E
3.75
(95)
C
3/4" NPT
2 Holes
.38 (10) Dia.
2.37
(60)
D
F
Optional
mounting flange
.1875 (5)
.2500 (6)
2.95
(75)
2
3.00
(76)
2.00
(51)
2
Optional
mounting
flange
4.67
(119)
G
G
3.50
(89)
.1875 (5)
.2500 (6)
1/2" NPT
or 3/4" NPT
2.95
(75)
3
4.87
(124)
1.25
(32)
Optional anchor
assembly
(P/N 032-8902-001)
Integral Mount with Flexible Probe
(shown with cast iron housing)
6
Remote Mount with Flexible Probe
(shown with cast iron housing)
5.55
(141)
.75
(19)
Optional
weight
(P/N 004-4355-001)
D I M E N S I O N A L
I N C H E S
S P E C I F I C A T I O N S
( m m )
4.63
(118) Dia.
3.00
(76)
B
B
1 Rotation
clearance
1 Rotation clearance
A
A
2.75
(70)
E
3.75
(95)
C
G
3/4" NPT
G
plugged
G
Optional
mounting
flange
4.11
(104)
G
plugged
2.37
(60)
2 Holes
.38 (10) Dia.
D
F
2.00
(51)
1/2" NPT
or 3/4" NPT
2
3.50
(89)
Optional
mounting
flange
2
3.00
(76)
IL
3
IL
.375 (10)
.375 (10)
Integral Mount with Guarded Probe
(shown with aluminum housing)
Remote Mount with Guarded Probe
(shown with aluminum housing)
Outline Dimensions
Housing
Standard Rigid Probe
D
E
F
Flexible Probe
D
E
A
B
NEMA 4X
Carbon steel
3.25
(82)
4.69
(119)
9.04
(230)
2.29
(58)
11.67
(296)
4.04
(103)
10.48
(266)
3.73
(95)
NEMA 4X/7/9
Cast iron
5.25
(133)
5.81
(148)
11.26
(286)
2.40
(61)
13.81
(351)
4.15
(105)
12.70
(323)
NEMA 4X/7/9
Aluminum
3.87
(98)
5.93
(151)
10.89
(276)
2.44
(61)
13.44
(341)
4.11
(104)
12.33
(313)
Conduit Connections (G)
NEMA 4X
Single conduit
3
⁄4" NPT
NEMA 4X/7/9
Single conduit
1" NPT
NEMA 4X/7/9
Dual conduit
1" NPT
C
C
Guarded Probe
D
E
F
C
11.67
(296)
4.04
(103)
9.84
(250)
3.17
(80)
11.67
(296)
4.04
(103)
F
4.67
(119)
13.81
(3.51)
4.15
(105)
12.06
(306)
3.28
(83)
13.81
(351)
4.15
(105)
4.71
(119)
13.44
(341)
4.11
(104)
11.69
(296)
3.32
(84)
13.44
(341)
4.11
(104)
NOTES:
Œ Allow 8 inch (203 mm) overhead clearance for cover removal.
 Standard process connection is 3⁄4" NPT. Consult probe bulletin
(50-125) for flange and other probe connections.
Ž Probe/amplifier connecting cable to be shielded twisted pair
22-gauge stranded conductors. Magnetrol P/N 009-7146-XXX,
where XXX = length in feet; 2500 feet (760 m) maximum; 800 feet
(240 m) maximum for intrinsically safe models. For lengths over
999 feet, use X009-7146-999 and X = total length in feet.
7
Q U A L I T Y
The quality assurance system in place at
Magnetrol guarantees the highest level of
quality throughout the company. Magnetrol
is committed to providing full customer
satisfaction both in quality products and
quality service.
The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment
to known international quality standards
providing the strongest assurance of product
and service quality available.
Several Kotron Model 822/832/842 RF Point
Switches are available for quick shipment,
usually within one week after factory receipt
of a complete purchase order, through the
Expedite Ship Plan (ESP).
color coded model number codes (standard
dimensions apply).
E S P
Expedite
Ship
Plan
To take advantage of ESP, simply match the
ESP service may not apply to orders of ten
units or more. Contact your local representative for lead times on larger volume orders,
as well as other products and options.
W A R R A N T Y
All Magnetrol electronic level and flow
controls are warranted free of defects in
materials or workmanship for one full year
from the date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered under the warranty; then, Magnetrol
will repair or replace the control at no cost
to the purchaser (or owner) other than
transportation.
Magnetrol shall not be liable for misapplication, labor claims, direct or consequential
damage or expense arising from the installation or use of equipment. There are no other
warranties expressed or implied, except
special written warranties covering some
Magnetrol products.
For additional information, see Instruction Manual 50-621.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype and Kotron® are registered trademarks of Magnetrol International.
BULLETIN: 50-104.7
EFFECTIVE: July 2004
SUPERSEDES: August 2001