D E S C R I P T I O N
The Sentinel is a unique, powerful level transmitter. The
leading-edge microprocessor-based circuitry has nonvolatile memory. The display and keypad simplify
calibration and setup of the instrument. Powerful diagnostics check all functions of the system, simplifying
troubleshooting. MagneCal™ offers the user the greatest
improvement in RF Capacitance—one small level change
is needed to calibrate.
F E A T U R E S
• Two or four SPDT relays with gold flash contacts for
alarm and control operation.
• Optional intrinsically safe probe circuitry (with
on-board barriers).
• 16-button keypad and 2 ¥ 16 LCD display.
• Isolated 4–20 mA output includes an active/passive
mode.
• Relays can be configured for sequential or lead/lag
pump control.
• One small level change (2% of span) needed for initial
probe calibration.
• 4–20 mA and up to eight control points can be programmed with no level change.
• Powerful self-diagnostics check the system, including
probe.
• Relay #1 can be dedicated as a diagnostics relay.
A P P L I C A T I O N S
• Continuous level measurement
• Interface measurement
• Hydrocarbons and solvents
• Slurries
• Acids
• High temperature/pressure liquids
T E C H N O L O G Y
The amount of capacitance developed in any vessel is
determined by: the size (surface area) of the probe; the
distance from the probe to its ground reference; and the
dielectric constant of the medium being measured.
Considering that the probe’s mounting position is fixed
and the dielectric of the medium is constant, then the
amount of capacitance developed in any vessel becomes
dependent upon the amount of the probe which is covered with media.
As the media rises and falls in the tank, the amount of
capacitance developed between the probe and the
ground reference also changes. The capacitance signal is
converted to a frequency proportional to the change in
level. The amplifier then converts this digital signal into
an isolated 4–20 mA analog output signal.
S P E C I F I C A T I O N S
Supply voltage
Power consumption
Ambient temperature range
Humidity
Accuracy
Repeatability
Linearity
Temperature effect
Operator interface:
Data entry
Display
Continuous Output:
Active signal
Passive signal
Range
Damping
Discrete output (SPDT) with gold flash contacts:
Set point range
Adjustable differential range
Time delay
Relay output:
AC
DC
Maximum remote cable length:
Standard
Intrinsically safe
A G E N C Y
120 VAC, 50/60 Hz (+10 – 15%)
240 VAC, 50/60 Hz (+10 – 15%)
24 VDC (±10%)
15 VA nominal
-40° to +160° F (-40° to +70° C)
99% non-condensing (electronics)
Better than ±1.0%
±0.1%
±0.5%
±0.01%/° F (±0.018/° C)
16-button keypad
2 line ¥ 16 character LCD display
4-20 mA (isolated), reversible, 1000 ohms max. loop resistance
4-20 mA (isolated), reversible, loop resistance
dependent on power supply
5 pF minimum; 50,000 pF maximum
0-90 seconds
0-50,000 pF
0.5 pF minimum; 50,000 pF maximum
0-90 seconds level rising, level falling, both
10 amp @ 120/240 VAC resistive
10 amp @ 30 VDC resistive
0.5 amp @ 125 VDC resistive
2500 feet (760 meters)
800 feet (240 meters)
A P P R O V A L S
Agency
Approved Model
Protection Method
Area Classification
CSA
804-XXXX-23X
804-XXXX-33X
Insulated rigid probes only
Explosion proof
Class I Div. 1, Groups C & D
Class II, Div. 1, Groups E, F, & G
Class III
TYPE 4X
804-XXXX-53X
804-XXXX-63X
Explosion proof ¿
with intrinsically safe
probe circuit
Integral units with IS probe circuit
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G ¿
Class III
TYPE 4X
Electronics
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G ¿
Class III
TYPE 4X
Remote probe
Class I Div. 1, Groups A, B, C & D
Class II, Div. 1, Groups E, F, & G ¿
Class III
TYPE 4X
2
¿ For Class II, Groups E & F insulated probes must be used
D I M E N S I O N A L
I N C H E S
S P E C I F I C A T I O N S
( m m )
B
1 Rotation
clearance
A
4.63
(118) Dia.
B
1 Rotation
clearance
C
3.00
(76)
A
2.75
(70)
G
G
C
plugged
G
3.23
(82)
D
3
Optional
mounting
flange
/4" NPT
G
plugged
2
2
D
Optional
mounting
flange
Optional
mounting
flange
.1875 (5)
.2500 (6)
2
2.95
(75)
.50 (13)
.625 (16)
.50 (13)
.625 (16)
Integral Mount with Standard Rigid Probe
B
1 Rotation
clearance
Rigid Probe
Integral Mount with Flexible Probe
4.63
(118) Dia.
3.00
(76)
A
2.75
(70)
E
G
4.67
(119)
G
2 Holes
.38 (10) Dia.
2.37
(60)
3/4"
Optional
mounting
flange
NPT
plugged
F
2
3.00
(76)
2.00
(51)
.1875 (5)
.2500 (6)
3.50
(89)
1/2"
NPT
or 3/4" NPT
3
2.95
(75)
Remote Mount
Flexible Probe
Outline Dimensions
Housing
NEMA 4X/7/9
Aluminum
A
B
3.87
(98)
5.93
(151)
Conduit
Connections
NEMA 4X/7/9
(remote probe housing)
Single conduit
NEMA 4X/7/9
Dual conduit
G
⁄4" NPT
3
1" NPT
C
10.89
(276)
Standard Rigid Probe
D
E
2.44
(61)
13.44
(341)
F
C
4.11
(104)
12.33
(313)
Flexible Probe
D
E
4.71
(119)
13.44
(341)
F
4.11
(104)
NOTES:
¿ Allow 8.00 (200) overhead clearance for cover removal.
¡ Standard process connection is 3⁄4" NPT. Consult probe bulletin (50-125) for
flange and other probe connections.
¬ Probe/amplifier connecting cable to be shielded, twisted pair, 22-gauge stranded
conductors, Magnetrol part number 009-7146-001; 2500 feet (760 m) maximum;
800 feet (240 m) maximum for intrinsically safe models.
3
M O D E L
N U M B E R
BASIC MODEL
804 Sentinel RF Level Transmitter
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
ELECTRONIC HOUSING
R
Aluminum, 1" NPT
Y
Aluminum, 1" NPT with 316 SS, remote housing
INPUT POWER
0
120 VAC
1
240 VAC
2
24 VDC
ANALOG OUTPUT/COMMUNICATIONS
1
4-20 mA
5
4-20 mA with RS-485 (Modbus)
ALARM/CONTROL OUTPUT
0
No relays
C
(2) 10 amp SPDT relays with gold flash contacts
D
(4) 10 amp SPDT relays with gold flash contacts
MOUNTING
2
Integral explosion proof
3
Remote explosion proof
5
Integral explosion proof w/IS safe probe circuit
6
Remote explosion proof w/IS safe probe circuit
8
0
4
3
0
P R O B E S
R E M O T E
A full range of rigid and flexible probes, for conductive and non-conductive process media, is available in various lengths and materials of
construction. For further information on probe assemblies, refer to bulletin 50-125.
Remote cable should be shielded, twisted pair, 22-gauge stranded conductors and may be ordered using Magnetrol part number 009-7146-001.
Cable length in feet must be specified at time of order; 2500 feet (760 m)
maximum; 800 feet (240 m) maximum for intrinsically safe models.
QUALITY
ESP
Expedite
Ship
Plan
WARRANTY
C A B L E
The quality assurance system in place at Magnetrol® guarantees
the highest level of quality throughout the company.
MAGNETROL is committed to providing full customer satisfaction both in quality products and quality service.
The MAGNETROL quality assurance system is registered to ISO
9001 affirming its commitment to known international quality
standards providing the strongest assurance of product/service
quality available.
Kotron® Model 804 transmitters are available for quick shipment,
usually within one week after factory receipt of a purchase
order, through the Expedite Ship Plan (ESP).
To take advantage of ESP, simply match the color coded model
number codes (standard dimensions apply).
Models covered by ESP service are conveniently color coded in
the selection data charts.
All MAGNETROL electronic level and flow controls are warranted
free of defects in materials or workmanship for one full year
from the date of original factory shipment. If returned within the
warranty period; and, upon factory inspection of the control, the
cause of the claim is determined to be covered under the warranty; then, MAGNETROL will repair or replace the control at no
cost to the purchaser (or owner) other than transportation.
ESP service may not apply to orders of ten units or more.
Contact your local representative for lead times on larger volume
orders, as well as other products and options.
MAGNETROL shall not be liable for misapplication, labor claims,
direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties
expressed or implied, except special written warranties covering
some MAGNETROL products.
For additional information, see Instruction Manual 50-604.
705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489
[email protected] • www.magnetrol.com
Copyright © 2015 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
BULLETIN: 50-118.4
EFFECTIVE: June 2015
SUPERSEDES: February 2001