MEANWELL PFC-1000

MP
450W/650W/1000W Modular Power
series
Features :
ZVT technology to reduce power dissipation and improve efficiency
Various output configuration is selectable
Built in active PFC, PF>0.95
Universal AC input/ full range
Remote Control on every individual output module
Remote Sense on every individual output module(MS-75,150,300)
Built in parallel function(MS-300)
Protections: Short circuit / Overload / Over voltage for all output modules
Additional 12V/0.1A auxiliary output for remote control
Cooling by built-in DC fan with fan alarm function
3 years warranty
Output Configuration Guide
MP
-
-
Single output(MS-150)
1 SLOT (150W max.)
SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7
450/650/1K0(450W/650W/1000W)
Modular Power with PFC
450W/650W(5SLOT)
Parallel or option code
(See Table 1.)
1000W(7SLOT)
Example: MP1K0- A
2
E
#
S
2
Voltage code
A
B
C
D
E
F
G
H
I
J
K
K
SLOT1
O/P:2V@25A
SLOT2,3
O/P:12V@25A
SLOT4
Blank Slot
Voltage
2V
3.3V
5V
7.5V
12V
15V
18V
24V
27V
33V
48V
Single output(MS-75)
1 SLOT (75W max.)
Single output(MS-300)
2 SLOT (300W max.)
Voltage code
2A
2B
2C
2D
2E
2F
2G
2H
2I
2J
2K
Voltage
2V
3.3V
5V
7.5V
12V
15V
18V
24V
27V
33V
48V
Voltage code
L
M
N
O
P
Q
Voltage
3.3V
5V
12V
15V
24V
48V
Dual output(MD-100)
1 SLOT (100W max.)
Voltage code
R
S
T
U
V
W
SLOT5
O/P:5V@10A
[email protected]
X
Voltage
5V
5V
5V
12V
5V
15V
24V
5V
24V
12V
12V
12V
15V
15V
SLOT6,7
O/P:[email protected]
SPECIFICATION
MODEL
PFC-450
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
PF>0.95/230VAC
POWER FACTOR
INPUT
EFFICIENCY
PROTECTION
FUNCTION
INRUSH CURRENT
25A/115VAC
40A/230VAC
<1.5mA/240VAC
OVER TEMPERATURE
OTHERS
84% typ.
9A/115VAC
4.5A/230VAC
30A/115VAC
50A/230VAC
650W max.
450W max.
Thermal switch detect on the heatsink of power MOSFET
13.5A/115VAC
20A/115VAC
6.7A/230VAC
40A/230VAC
1000W max.
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Output shutdown when FAN is malfunction
REMOTE CONTROL
RC+/RC-: 0 ~ 0.8V or Short, Power ON
AUXILIARY POWER(AUX)
[email protected](only for Remote ON/OFF Control)
-20 ~ +70 (Refer to output load derating curve)
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
(Note 5)
3.2A/230VAC
FAN ALARM
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
EMC
84% typ.
6.3A/115VAC
WORKING TEMP.
SAFETY &
PF>0.98/115VAC at full load
AC CURRENT
TOTAL OUTPUT POWER
PFC-1000
120 ~370VDC
Note.1 82.5% typ.
LEAKAGE CURRENT
OUTPUT
PFC-650
RC+/RC-: 4 ~ 12V or Open, Power OFF
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
/ 70% RH
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
DIMENSION
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-1, EN61204-3, light industry level, criteria A
254*127*63.5mm (L*W*H)
278*127*63.5mm (L*W*H)
278*177.8*63.5mm (L*W*H)
PACKING
1.8Kg(typ.); 6pcs / 11.8Kg / 1.25CUFT
2.16Kg(typ.); 6pcs / 14Kg / 1.34CUFT
3Kg(typ.); 6pcs /19Kg / 1.74CUFT
File Name:MP-450,650,1K0-SPEC 2010-10-18
MP
450W/650W/1000W Modular Power
series
SPECIFICATION
1 SLOT Single output (150W) MS-150
OUTPUT VOLTAGE CODE
MS-150A
MS-150B
MS-150C MS-150D MS-150E
MS-150F
MS-150G MS-150H MS-150I
MS-150J
DC VOLTAGE
2V
3.3V
5V
7.5V
12V
15V
18V
24V
27V
33V
48V
RATED CURRENT
25A
25A
25A
18A
13A
10A
8.5A
6.5A
5.8A
4.7A
3.2A
0 ~ 25A
CURRENT RANGE
PEAK LOAD
OUTPUT
(MS-150)
Note.4 30A
50W
RATED POWER
RIPPLE & NOISE (max.) Note.2 50mVp-p
MS-150K
0 ~ 25A
0 ~ 25A
0 ~ 18A
0 ~ 13A
0 ~ 10A
0 ~ 8.5A
0 ~ 6.5A
0 ~ 5.8A
0 ~ 4.7A
0 ~ 3.2A
30A
30A
20.7A
15A
11.5A
9.8A
7.5A
6.7A
5.4A
3.68A
156W
150W
153W
156W
156.6W
155.1W
153.6W
82.5W
125W
135W
80mVp-p
80mVp-p
100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p
4 ~ 6V
6 ~ 9V
30 ~ 40V
40 ~ 53V
VOLTAGE TOLERANCE Note.3
3.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
0.2%
LOAD REGULATION
2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.6 ~ 2.6V 2.6 ~ 4V
VOLTAGE ADJ. RANGE
9 ~ 13.2V 13.2 ~ 16.8V 16.8 ~ 20V 20 ~ 26.4V 25 ~ 31V
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
121 ~ 150% rated output power
116 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVERLOAD
PROTECTION
2.7 ~ 4V
OVER VOLTAGE
FUNCTION
REMOTE INHIBIT CONTROL
4.1 ~ 5V
6.1 ~ 7.5V 9.1 ~ 11.2V 13.3 ~ 18V 16.9 ~ 22V 20.1 ~ 26V 26.5 ~ 35V 31.1 ~ 39V 40.1 ~ 48V 53.1 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
2 SLOT Single output (300W) MS-300
OUTPUT VOLTAGE CODE
MS-300-2A MS-300-2B MS-300-2C MS-300-2D MS-300-2E MS-300-2F MS-300-2G MS-300-2H MS-300-2I
DC VOLTAGE
2V
3.3V
5V
7.5V
12V
15V
18V
24V
27V
33V
48V
RATED CURRENT
50A
50A
50A
40A
25A
20A
16.7A
12.5A
11.2A
9.1A
6.3A
0 ~ 50A
CURRENT RANGE
PEAK LOAD
OUTPUT
(MS-300)
Note.4 57.5A
100W
RATED POWER
RIPPLE & NOISE (max.) Note.2 80mVp-p
0 ~ 50A
0 ~ 40A
0 ~ 25A
0 ~ 20A
0 ~ 16.7A 0 ~ 12.5A 0 ~ 11.2A
0 ~ 9.1A
0 ~ 6.3A
57.5A
46A
29A
23A
19.2A
14.4A
12.9A
10.5A
7.2A
300W
300W
300.6W
300W
302.4W
300.3W
302.4W
165W
250W
300W
80mVp-p
80mVp-p
100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 300mVp-p
4 ~ 6V
6 ~ 9V
30 ~ 40V
40 ~ 53V
3.0%
2.0%
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
0.2%
LOAD REGULATION
2.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
1.6 ~ 2.6V 2.6 ~ 4V
9 ~ 13.2V 13.2 ~ 16.8V 16.8 ~ 20V 20 ~ 26.4V 25 ~ 31V
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
116 ~ 150% rated output power
OVERLOAD
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3 ~ 4V
OVER VOLTAGE
FUNCTION
0 ~ 50A
57.5A
VOLTAGE TOLERANCE Note.3
VOLTAGE ADJ. RANGE
PROTECTION
MS-300-2J MS-300-2K
4.1 ~ 5V
6.1 ~ 7.5V 9.1 ~ 11.2V 13.3 ~ 18V 16.9 ~ 22V 20.1 ~ 26V 26.5 ~ 35V 31.1 ~ 39V 40.1 ~ 48V 53.1 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
REMOTE INHIBIT CONTROL
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
1 SLOT Single output (75W) MS-75
OUTPUT VOLTAGE CODE
MS-75L
MS-75M
MS-75N
MS-75O
MS-75P
MS-75Q
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
15A
15A
6.3A
5A
3.2A
1.6A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 6.3A
0 ~ 5A
0 ~ 3.2A
0 ~ 1.6A
1.8A
PEAK LOAD
OUTPUT
(MS-75)
Note.4 17.3A
RATED POWER
49.5W
RIPPLE & NOISE (max.) Note.2 80mVp-p
17.3A
7.3A
5.8A
3.7A
75W
75.6W
75W
76.8W
76.8W
80mVp-p
150mVp-p
150mVp-p
150mVp-p
250mVp-p
9 ~ 13.2V
13.2 ~ 16.8V
20 ~ 26.4V
40 ~ 53V
2.6 ~ 4V
4 ~ 6V
VOLTAGE TOLERANCE Note.3
2.0%
2.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
LOAD REGULATION
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
VOLTAGE ADJ. RANGE
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
OVERLOAD
PROTECTION
OVER VOLTAGE
FUNCTION
REMOTE INHIBIT CONTROL
116 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
4.1 ~ 5V
6.1 ~ 7.5V
13.3 ~ 18V
16.9 ~ 22V
26.5 ~ 35V
53.1 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
File Name:MP-450,650,1K0-SPEC 2010-10-18
MP
450W/650W/1000W Modular Power
series
SPECIFICATION
1 SLOT Isolated Dual output (100W) MD-100
OUTPUT
(MD-100)
OUTPUT VOLTAGE CODE
MD-100R
MD-100S
MD-100T
MD-100U
MD-100V
MD-100W
MD-100X
DC VOLTAGE
5V
5V
5V
12V
5V
15V
24V
5V
24V
12V
12V
12V
15V
RATED CURRENT
10A
8A
10A
4.2A
10A
3.4A
2.5A
8A
2.5A
3.4A
5A
3.4A
4A
CURRENT RANGE
2 ~ 10A 0 ~ 8A
2.7A
2 ~ 10A 0 ~ 5.8A 2 ~ 10A 0 ~ 4.7A 0.5 ~ 3A 0 ~ 10A 0.6 ~ 3A 0 ~ 4.7A 1 ~ 5A 0 ~ 5.8A 1 ~ 4.7A
0 ~ 4.7A
RATED POWER
Note.6 90W
100.8W
100.8W
100.4W
101W
100W
100.5W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 150mVp-p 200mVp-p 100mVp-p 240mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V 4.75 ~ 5.5V 4.75 ~ 5.5V 11.4 ~ 13.2V 4.75 ~ 5.5V 14.2 ~ 16.5V 22.8 ~ 26.4V 4.75 ~ 5.5V 22.8 ~ 26.4V 11.4 ~ 13.2V 11.4~ 13.2V 11.4~ 13.2V 14.2 ~ 16.5V 14.2 ~ 16.5V
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
2.0%
3.0%
2.0%
3.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
1.0%
0.5%
1.0%
0.5%
LOAD REGULATION
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
1.0%
2.0%
1.0%
2.0%
1.0%
SETUP, RISE, HOLD UP TIME 1500ms, 50ms, 20ms at full load
105 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVERLOAD
PROTECTION
OVER VOLTAGE
FUNCTION
15V
REMOTE INHIBIT CONTROL
5.6 ~ 7.2V 5.6 ~ 7.2V 5.6 ~ 7.2V 13.3 ~ 17V 5.6 ~ 7.2V 16.6 ~ 22V 26.5 ~ 34V 5.6 ~ 7.2V 26.5 ~ 34V 13.3 ~ 17V 13.3 ~ 17V 13.3 ~ 17V 16.6 ~ 22V
16.6 ~ 22V
Protection type : Shut down o/p voltage, re-power on to recover
RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON
RC+/RC-: 4 ~ 12V POWER OFF
1. MP450:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.
5V(Voltage code C)*1, 12V(Voltage code E)*1, 24V(Voltage code H)*1, 5V(Voltage code M)*1.
MP650:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.
5V(Voltage code C)*2, 12V(Voltage code E)*1, 24V(Voltage code H)*2.
MP1K0:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.
5V(Voltage code C)*2, 12V(Voltage code E)*2, 24V(Voltage code H)*3.
The hold-up time of above combination is 20ms(typ.)
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 35% Duty cycle maximum within every 10 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
6. If the output voltage adjust to higher level, the rated current should be derated to meet the total rated power for both outputs(For MD-100 only).
NOTE
Table 1. Parellel code(For MS-300 only)
SLOT6
SLOT7
X
-----
-----
1
-----
-----
2
-----
-----
Code
SLOT1
SLOT2
SLOT3
SLOT4
SLOT5
3
4
5
6
Code X,1,2 for MP450,MP650
Code X,1,2,3,4,5,6 for MP1K0
File Name:MP-450,650,1K0-SPEC 2010-10-18
MP
450W/650W/1000W Modular Power
Mechanical Specification
series
Unit:mm
MP450
12 max.
254
19
147.5
19
16 max.
38
63.5
12.5
147.5
1
2
3
12.25
8-M4(Both Sides)
CN4
4-M4
3
2
101.5
127
Air flow
direction
1
TB1
10
8.2
MP650
12 max.
278
19 16 max.
171.5
19
38
63.5
12.5
171.5
12.25
8-M4(Both Sides)
CN4
1
2
3
Air flow
direction
3
2
101.5
127
4-M4
1
TB1
10
8.2
File Name:MP-450,650,1K0-SPEC 2010-10-18
MP
450W/650W/1000W Modular Power
series
Mechanical Specification
MP1K0
12 max.
278
19 16 max.
171.5
19
38
63.5
12.5
171.5
15.65
8-M4(Both Sides)
CN4
1
2
3
3
2
152.4
Air flow
direction
177.8
4-M4
1
TB1
10
8.2
TB1(PFC-450/650/1K0)
Pin No.
1
2
3
Assignment
AC/L
AC/N
FG
CN4(PFC-450/650/1K0) : JST B3B-XH or equivalent
Assignment
Pin No.
1
+RC: +Remote ON/OFF
2
-RC: -Remote ON/OFF
3
VCC: 12V/0.1A auxiliary output
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T-P0.6
or equivalent
Mechanism of Output Modules
Unit:mm
MS-75
138
16 max.
21 max.
60
CN51
4
1
3 max.
Output Connector( CN51) : JST B4B-XH or equivalent
Pin No.
1
2
3
4
-V
+V
SVR1
Assignment
+S: +Remote sensing
-S: -Remote sensing
+RC: +Remote ON/OFF
-RC: -Remote ON/OFF
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T-P0.6
or equivalent
MS-150
138
21 max.
16 max.
60
CN20
4
1
Output Connector( CN20) : JST B4B-XH or equivalent
-V
+V
SVR2
3 max.
Pin No.
1
2
3
4
Assignment
+S: +Remote sensing
-S: -Remote sensing
+RC: +Remote ON/OFF
-RC: -Remote ON/OFF
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T-P0.6
or equivalent
File Name:MP-450,650,1K0-SPEC 2010-10-18
MP
450W/650W/1000W Modular Power
series
Mechanism of Output Modules
MS-300
138
42 max.
16 max.
3 max.
-V
60
-V
+V
1
+V
6
CN33
SVR3
Output Connector(CN33) : JST B6B-XH or equivalent
Pin No.
1
2
3
4
5
6
Assignment
+S: +Remote sensing
-S: -Remote sensing
+RC: +Remote ON/OFF
-RC: -Remote ON/OFF
P:Current sharing
G:GND
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T-P0.6
or equivalent
NOTE: 1.The voltage difference among each output should be minimized that less than 2% is required.
2.The total output current must not exceed the value determined by the following equation.
(Output current at parallel operation) = (The rated current per unit) (Number of unit) 0.9
MD-100
138
21 max.
16 max.
3 max.
GND2
60
+V2
CN41
GND1
+V1
2
1
SVR4 SVR5
Output Connector(CN41) : JST B2B-ZR or equivalent
Pin No.
1
2
Assignment
+RC
-RC
Mating Housing
JST ZHR-2
or equivalent
Terminal
JST SZH-002T-P0.5
or equivalent
NOTE: 1.Remote ON/OFF of CN4 turn ON/OFF the entire power system
2.Remote ON/OFF of CN20,CN33,CN41,CN51 turn ON/OFF the individual output module
3.SVR1~5: DC output voltage adjustment(SVR4 for CH2 of MD-100,SVR5 for CH1 of MD-100)
Derating Curve
Static Characteristics
Ta=25
80
RATED POWER (%)
RATED POWER (%)
100
60
50
40
20
-20
100
90
85
80
70
80
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (HORIZONTAL)
85
90
100
120
140
160
180
200
220
240
264
INPUT VOLTAGE (V) 60Hz
File Name:MP-450,650,1K0-SPEC 2010-10-18