QP-150 150W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Over load / Over voltage Forced air cooling by built-in DC fan CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION QP-150-3A MODEL OUTPUT INPUT CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 12V -5V 5V 3.3V 12V -12V 5V 3.3V 15V -15V RATED CURRENT 10A 10A 5A 0.6A 10A 10A 5A 0.6A 10A 10A 4A 0.6A CURRENT RANGE 3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A RATED POWER (max.) 146W VOLTAGE ADJ. RANGE CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% +8,-6% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD UP TIME (Typ.) 24ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 73% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC COLD START 800ms, 50ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 75% 74% 1.2A/230VAC 40A/230V <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 141.5K hrs min. DIMENSION 199*99*50mm (L*W*H) 0.93Kg; 20pcs/19.6Kg/1.28CUFT PACKING 5.0% 24ms/115VAC at full load LEAKAGE CURRENT WITHSTAND VOLTAGE NOTE CH1: 4.75 ~ 5.5V 3.0% WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS OTHERS 152W VOLTAGE TOLERANCE Note.3 WORKING TEMP. (Note 4) 150.2W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p OVER TEMPERATURE(OPTION) EMC QP-150-3C CH1 PROTECTION OVER VOLTAGE SAFETY & QP-150-3B OUTPUT NUMBER MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:QP-150-SPEC 2010-10-18 QP-150 150W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage Forced air cooling by built-in DC fan CH4: Polarity is selectable Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION QP-150-3D MODEL OUTPUT INPUT CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 24V -12V 5V 12V 24V -12V 5V 15V 24V -15V RATED CURRENT 10A 10A 2.5A 0.6A 10A 4A 2A 0.6A 10A 3A 2A 0.6A CURRENT RANGE 3 ~ 15A 0 ~ 15A 0.3 ~ 3A 0 ~ 1A 3 ~ 15A 0 ~ 5A 0.4 ~ 3A 0 ~ 1A 3 ~ 15A 0 ~ 5A 0.4 ~ 3A 0 ~ 1A RATED POWER (max.) 150.2W 150.2W 152W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms/230VAC HOLD UP TIME (Typ.) 24ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC COLD START 800ms, 50ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 78% 78% 1.2A/230VAC 40A/230V <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note 4) CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 Compliance to EN55022 (CISPR22) Class B / 70% RH Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 141.5K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 0.93Kg; 20pcs/19.6Kg/1.28CUFT PACKING CH2:17.25 ~ 20.25V 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) HARMONIC CURRENT DIMENSION 5.0% 24ms/115VAC at full load LEAKAGE CURRENT OVER TEMPERATURE(OPTION) NOTE QP-150F CH1 PROTECTION OVER VOLTAGE OTHERS QP-150D OUTPUT NUMBER ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:QP-150-SPEC 2010-10-18 QP-150 150W Quad Output with PFC Function Mechanical Specification Case No. 916B series Unit:mm 199 20 35 133 25 117 70 48.5 65 LED 99 16 10 49.5 5-M3 L=6mm 119 51 79 2-M4 4 3 2 1 38 7.62 6.15 35.2 +V ADJ.2 +V ADJ.1 10 9 8 7 6 5 15 142 Air flow direction 25 Terminal Pin No. Assignment : Assignment Assignment Pin No. Pin No. 5 AC/L DC OUTPUT V3 1 AC/N 2 6,7 DC OUTPUT V1 FG 8,9 DC OUTPUT COM 3 DC OUTPUT V4 10 DC OUTPUT V2 4 50 12.5 25 25 9 max. 6-M4 L=6mm FAN Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT PWM & PFC CONTROL FG RECTIFIERS & FILTER RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER V4 REGULATOR V3 RECTIFIERS & FILTER V2 +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:QP-150-SPEC 2010-10-18 QP-150B,C 150W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage Forced air cooling by built-in DC fan Fixed switching frequency at 100KHz 3 years warranty .. SPECIFICATION QP-150B MODEL OUTPUT INPUT CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 12V -12V -5V 5V 15V -15V -5V RATED CURRENT 15A 4A 2A 0.6A 15A 3A 2A 0.6A CURRENT RANGE 3 ~ 15A 0.4 ~ 5A 0.3 ~ 2A 0 ~ 1A 3 ~ 15A 0.4 ~ 4A 0.3 ~ 2A 0 ~ 1A RATED POWER (max.) 150W 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p VOLTAGE ADJ. RANGE 3.0% 6.0% +10,-6% 5.0% 3.0% +6,-10% 8.0% 1.0% 2.0% 2.0% 1.0% 1.0% 2.0% 2.0% 1.0% LOAD REGULATION 2.0% 6.0% 6.0% 2.0% 2.0% 6.0% 6.0% 2.0% SETUP, RISE TIME 1000ms, 50ms at full load HOLD UP TIME (Typ.) 24ms at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC COLD START 77% 1.2A/230VAC 40A <3.5mA / 240VAC OVERLOAD CH1:5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B / 70% RH HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 141.5K hrs min. MIL-HDBK-217F (25 199*99*50mm (L*W*H) 1.1Kg; 20pcs/22Kg/1.28CUFT DIMENSION PACKING NOTE PF>0.98/115VAC at full load 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed SAFETY STANDARDS WITHSTAND VOLTAGE 5.0% 127 ~ 370VDC LEAKAGE CURRENT WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION OTHERS CH1:4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 WORKING TEMP. (Note 4) CH1:4.75 ~ 5.5V LINE REGULATION OVER TEMPERATURE(OPTION) EMC 153W RIPPLE & NOISE (max.) Note.2 100mVp-p PROTECTION OVER VOLTAGE SAFETY & QP-150C OUTPUT NUMBER ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) File Name:QP-150B,C-SPEC 2010-10-18 QP-150B,C 150W Quad Output with PFC Function Mechanical Specification Case No. 916B series Unit:mm 199 20 35 133 25 117 70 48.5 65 LED 4 3 2 1 99 16 10 49.5 119 79 51 35.2 2-M4 5-M3 L=6mm 38 6.15 7.62 10 +V ADJ.1 9 8 7 6 5 15 142 Air flow direction 25 Terminal Pin No. Assignment : Assignment Assignment Pin No. Pin No. AC/L DC OUTPUT V3 1 5 DC OUTPUT V1 AC/N 2 6,7 8,9 DC OUTPUT COM 3 FG 10 DC OUTPUT V2 4 DC OUTPUT V4 50 12.5 25 25 9 max. 6-M4 L=6mm Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT PWM & PFC CONTROL FG RECTIFIERS & FILTER RECTIFIERS & FILTER MA & CONTROL RECTIFIERS & FILTER V4 REGULATOR V3 FAN RECTIFIERS & FILTER V2 +5V COM DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:QP-150B,C-SPEC 2010-10-18