MEANWELL QP-150

QP-150
150W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Over load / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
QP-150-3A
MODEL
OUTPUT
INPUT
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
3.3V
12V
-5V
5V
3.3V
12V
-12V
5V
3.3V
15V
-15V
RATED CURRENT
10A
10A
5A
0.6A
10A
10A
5A
0.6A
10A
10A
4A
0.6A
CURRENT RANGE
3 ~ 15A
0 ~ 15A
0.4 ~ 5A
0 ~ 1A
3 ~ 15A
0 ~ 15A
0.4 ~ 5A
0 ~ 1A
3 ~ 15A
0 ~ 15A
0.4 ~ 5A
0 ~ 1A
RATED POWER (max.)
146W
VOLTAGE ADJ. RANGE
CH2: 3.14 ~ 3.63V
CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
3.0%
6.0%
5.0%
3.0%
3.0%
6.0%
5.0%
3.0%
3.0%
+8,-6%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
SETUP, RISE TIME
800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
24ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
73%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.5A/115VAC
COLD START
800ms, 50ms/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
75%
74%
1.2A/230VAC
40A/230V
<3.5mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V
CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
/ 70% RH
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
141.5K hrs min.
DIMENSION
199*99*50mm (L*W*H)
0.93Kg; 20pcs/19.6Kg/1.28CUFT
PACKING
5.0%
24ms/115VAC at full load
LEAKAGE CURRENT
WITHSTAND VOLTAGE
NOTE
CH1: 4.75 ~ 5.5V
3.0%
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
OTHERS
152W
VOLTAGE TOLERANCE Note.3
WORKING TEMP.
(Note 4)
150.2W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
OVER TEMPERATURE(OPTION)
EMC
QP-150-3C
CH1
PROTECTION OVER VOLTAGE
SAFETY &
QP-150-3B
OUTPUT NUMBER
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:QP-150-SPEC 2010-10-18
QP-150
150W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
QP-150-3D
MODEL
OUTPUT
INPUT
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
3.3V
24V
-12V
5V
12V
24V
-12V
5V
15V
24V
-15V
RATED CURRENT
10A
10A
2.5A
0.6A
10A
4A
2A
0.6A
10A
3A
2A
0.6A
CURRENT RANGE
3 ~ 15A
0 ~ 15A
0.3 ~ 3A
0 ~ 1A
3 ~ 15A
0 ~ 5A
0.4 ~ 3A
0 ~ 1A
3 ~ 15A
0 ~ 5A
0.4 ~ 3A
0 ~ 1A
RATED POWER (max.)
150.2W
150.2W
152W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
CH1: 4.75 ~ 5.5V
CH2: 11.4 ~ 13.2V
CH1: 4.75 ~ 5.5V
CH2: 14.3 ~ 16.5V
VOLTAGE TOLERANCE Note.3
3.0%
3.0%
6.0%
5.0%
3.0%
3.0%
6.0%
5.0%
3.0%
3.0%
6.0%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
SETUP, RISE TIME
800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
24ms/230VAC
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.5A/115VAC
COLD START
800ms, 50ms/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
78%
78%
1.2A/230VAC
40A/230V
<3.5mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 4)
CH1:5.75 ~ 6.75V
CH2:3.8 ~ 4.4V
CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
Compliance to EN55022 (CISPR22) Class B
/ 70% RH
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
141.5K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
0.93Kg; 20pcs/19.6Kg/1.28CUFT
PACKING
CH2:17.25 ~ 20.25V
95
5 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
HARMONIC CURRENT
DIMENSION
5.0%
24ms/115VAC at full load
LEAKAGE CURRENT
OVER TEMPERATURE(OPTION)
NOTE
QP-150F
CH1
PROTECTION OVER VOLTAGE
OTHERS
QP-150D
OUTPUT NUMBER
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:QP-150-SPEC 2010-10-18
QP-150
150W Quad Output with PFC Function
Mechanical Specification
Case No. 916B
series
Unit:mm
199
20
35
133
25
117
70
48.5
65
LED
99
16
10
49.5
5-M3 L=6mm
119
51
79
2-M4
4
3
2
1
38
7.62
6.15
35.2
+V ADJ.2
+V ADJ.1
10
9
8
7
6
5
15
142
Air flow
direction
25
Terminal Pin No. Assignment :
Assignment
Assignment
Pin No.
Pin No.
5
AC/L
DC OUTPUT V3
1
AC/N
2
6,7
DC OUTPUT V1
FG
8,9
DC OUTPUT COM
3
DC OUTPUT V4
10
DC OUTPUT V2
4
50
12.5
25
25
9 max.
6-M4 L=6mm
FAN
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
PWM & PFC
CONTROL
FG
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
MA
&
CONTROL
RECTIFIERS
&
FILTER
V4
REGULATOR
V3
RECTIFIERS
&
FILTER
V2
+5V
COM
DETECTION CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
50
40
90
100
115
135
155
230 264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-150-SPEC 2010-10-18
QP-150B,C
150W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
QP-150B
MODEL
OUTPUT
INPUT
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
12V
-12V
-5V
5V
15V
-15V
-5V
RATED CURRENT
15A
4A
2A
0.6A
15A
3A
2A
0.6A
CURRENT RANGE
3 ~ 15A
0.4 ~ 5A
0.3 ~ 2A
0 ~ 1A
3 ~ 15A
0.4 ~ 4A
0.3 ~ 2A
0 ~ 1A
RATED POWER (max.)
150W
150mVp-p
150mVp-p
100mVp-p
100mVp-p
150mVp-p
150mVp-p
100mVp-p
VOLTAGE ADJ. RANGE
3.0%
6.0%
+10,-6%
5.0%
3.0%
+6,-10%
8.0%
1.0%
2.0%
2.0%
1.0%
1.0%
2.0%
2.0%
1.0%
LOAD REGULATION
2.0%
6.0%
6.0%
2.0%
2.0%
6.0%
6.0%
2.0%
SETUP, RISE TIME
1000ms, 50ms at full load
HOLD UP TIME (Typ.)
24ms at full load
VOLTAGE RANGE
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
76%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.5A/115VAC
COLD START
77%
1.2A/230VAC
40A
<3.5mA / 240VAC
OVERLOAD
CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW1)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
/ 70% RH
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
141.5K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
1.1Kg; 20pcs/22Kg/1.28CUFT
DIMENSION
PACKING
NOTE
PF>0.98/115VAC at full load
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SAFETY STANDARDS
WITHSTAND VOLTAGE
5.0%
127 ~ 370VDC
LEAKAGE CURRENT
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3
WORKING TEMP.
(Note 4)
CH1:4.75 ~ 5.5V
LINE REGULATION
OVER TEMPERATURE(OPTION)
EMC
153W
RIPPLE & NOISE (max.) Note.2 100mVp-p
PROTECTION OVER VOLTAGE
SAFETY &
QP-150C
OUTPUT NUMBER
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
File Name:QP-150B,C-SPEC 2010-10-18
QP-150B,C
150W Quad Output with PFC Function
Mechanical Specification
Case No. 916B
series
Unit:mm
199
20
35
133
25
117
70
48.5
65
LED
4
3
2
1
99
16
10
49.5
119
79
51
35.2
2-M4
5-M3 L=6mm
38
6.15
7.62
10
+V ADJ.1
9
8
7
6
5
15
142
Air flow
direction
25
Terminal Pin No. Assignment :
Assignment
Assignment
Pin No.
Pin No.
AC/L
DC OUTPUT V3
1
5
DC OUTPUT V1
AC/N
2
6,7
8,9
DC OUTPUT COM
3
FG
10
DC OUTPUT V2
4
DC OUTPUT V4
50
12.5
25
25
9 max.
6-M4 L=6mm
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
PWM & PFC
CONTROL
FG
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
MA
&
CONTROL
RECTIFIERS
&
FILTER
V4
REGULATOR
V3
FAN
RECTIFIERS
&
FILTER
V2
+5V
COM
DETECTION CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-10
-10
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60 (HORIZONTAL)
60
50
40
90
100
115
135
155
230 264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-150B,C-SPEC 2010-10-18