QP-200 200W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH1,2 can be adjustable from -5~+10% With power good and fail signal output(Optional) Built-in remote sense function for CH1,2 100% full load burn-in test CH4 can set to positive after consult us before delivery(Optional) Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty .. SPECIFICATION QP-200D MODEL CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 12V 24V -12V 5V 15V 24V -15V 5V 3.3V 12V -5V RATED CURRENT 5V 15A 4A 3A 0.7A 15A 3A 3A 0.7A 15A 15A 6A 0.7A CURRENT RANGE 3 ~ 20A 0 ~ 6A 0.4 ~ 5A 0 ~ 1A 3 ~ 20A 0 ~ 5A 0.4 ~ 5A 0 ~ 1A 3 ~ 20A 0 ~ 20A 0.5 ~ 8A 0 ~ 1A 7A 6A 1A 6A 6A 1A 20A 8A 1A PEAK CURRENT 203.4W Note.4 20A 202.5W 20A 200W 20A RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p CH2: 14.25 ~ 16.5V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 CH1: 4.75 ~ 5.5V 3.0% 3.0% +10,-6% 6.0% 3.0% 3.0% +10,-6% 6.0% 3.0% 3.0% +8,-10% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V 6.0% 24ms at full load HOLD UP TIME (Typ.) VOLTAGE RANGE CH2: 11.4 ~ 13.2V 800ms, 50ms at full load SETUP, RISE TIME INPUT QP-200-3A CH1 RATED POWER OUTPUT QP-200F OUTPUT NUMBER Note.6 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 75% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3.5A/115VAC 2A/230VAC COLD START 30A PF>0.98/115VAC at full load 75% 72% LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE OVER TEMPERATURE CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover 95 5 CH2:17.25 ~ 20.25V CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V (TSW1) detect on heatsink of Q1,Q2 power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note 5) OTHERS -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 160.6K hrs min. DIMENSION 215*115*50mm (L*W*H) 1.2Kg; 12pcs/15.4Kg/0.92CUFT PACKING NOTE 20 ~ 90% RH non-condensing MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-200-SPEC 2008-07-08 QP-200 200W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH1,2 can be adjustable from -5~+10% With power good and fail signal output(Optional) Built-in remote sense function for CH1,2 100% full load burn-in test CH4 can set to positive after consult us before delivery(Optional) Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty .. SPECIFICATION QP-200-3B MODEL CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 3.3V 12V -12V 5V 3.3V 15V -15V 5V 3.3V 24V -12V RATED CURRENT 15A 15A 6A 0.7A 15A 15A 5A 0.7A 10A 15A 4A 0.7A CURRENT RANGE 3 ~ 20A 0 ~ 20A 0.5 ~ 8A 0 ~ 1A 3 ~ 20A 0 ~ 20A 0.5 ~ 6A 0 ~ 1A 3 ~ 15A 0 ~ 20A 0.4 ~ 5A 0 ~ 1A 20A 8A 1A 20A 20A 7A 1A 20A 20A 6A 1A 204.9W RATED POWER Note.4 20A 210W 203.9W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% 3.0% +8,-10% 6.0% 3.0% 3.0% +10,-6% 6.0% 3.0% 3.0% +10,-6% LINE REGULATION 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% SETUP, RISE TIME 800ms, 50ms at full load HOLD UP TIME (Typ.) 24ms at full load VOLTAGE RANGE INPUT QP-200-3D CH1 PEAK CURRENT OUTPUT QP-200-3C OUTPUT NUMBER Note.6 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC EFFICIENCY (Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 3.5A/115VAC 2A/230VAC COLD START 30A PF>0.98/115VAC at full load 72% 74% LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE 6.0% CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of Q1,Q2 power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. OVER TEMPERATURE WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) OTHERS -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 160.6K hrs min. DIMENSION 215*115*50mm (L*W*H) 1.2Kg; 12pcs/15.4Kg/0.92CUFT PACKING NOTE 20 ~ 90% RH non-condensing MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-200-SPEC 2008-07-08 QP-200 200W Quad Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan CH1,2 can be adjustable from -5~+10% With power good and fail signal output(Optional) Built-in remote sense function for CH1,2 100% full load burn-in test CH4 can set to positive after consult us before delivery(Optional) Fixed switching frequency at PFC:67KHz PWM:134KHz 3 years warranty .. SPECIFICATION QP-200-3E MODEL OUTPUT NUMBER CH1 CH2 CH3 DC VOLTAGE 3.3V 24V -15V RATED CURRENT 5V 10A 15A 4A 0.7A CURRENT RANGE 3 ~ 15A 0 ~ 20A 0.4 ~ 5A 0 ~ 1A RATED POWER 206W 20A 6A 1A 100mVp-p 150mVp-p 150mVp-p PEAK CURRENT OUTPUT Note.4 20A RIPPLE & NOISE (max.) Note.2 100mVp-p CH1: 4.75 ~ 5.5V VOLTAGE ADJ. RANGE CH2: 3.14 ~ 3.63V VOLTAGE TOLERANCE Note.3 3.0% 3.0% +10,-6% 6.0% LINE REGULATION 1.0% 1.0% 2.0% 1.0% LOAD REGULATION 2.0% 2.0% 6.0% 2.0% 800ms, 50ms at full load SETUP, RISE TIME 24ms at full load HOLD TIME (Typ.) VOLTAGE RANGE Note.6 90 ~ 264VAC FREQUENCY RANGE POWER FACTOR (Typ.) INPUT CH4 EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 47 ~ 63Hz PF>0.95/230VAC 74% 3.5A/115VAC 127 ~ 370VDC PF>0.98/115VAC at full load 2A/230VAC COLD START 30A LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) detect on heatsink of Q1,Q2 power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms -10 ~ +60 (Refer to output load derating curve) WORKING TEMP. OVER TEMPERATURE WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 5) OTHERS HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 160.6K hrs min. DIMENSION 215*115*50mm (L*W*H) 1.2Kg; 12pcs/15.4Kg/0.92CUFT PACKING NOTE MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:QP-200-SPEC 2008-07-08 QP-200 200W Quad Output with PFC Function Mechanical Specification Case No. 912B series Unit:mm 117.5 32.5 150 27.5 177.5 LED 115 95 50 4-M4 L=5mm 5-M3 L=3mm 10 50.5 47.5 16 8 9.5 9 8 7 6 5 4 3 2 1 32.5 1 36.5 CN2 15 Terminal Pin No. Assignment Pin No. Assignment Pin No. 1 5 AC/L AC/N 2 6 3 FG 7,8 DC OUTPUT V4 4 9 Air flow direction 215 150 32.5 51.5 50 CL 25 13 max. Terminal Pin No. Assignment Pin No. Assignment Mating Housing V1(+S) V2(-S) 1 4 JST SXH-001T-P0.6 JST XHP V1(-S) PF/PG 2 5 or equivalent or equivalent V2(+S) GND 3 6 PFC fosc : 67KHz PWM fosc : 134KHz RECTIFIERS & FILTER Block Diagram EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT REGULATOR V4 FAN RECTIFIERS & FILTER V3 MA & CONTROL PWM & PFC CONTROL FG Assignment DC OUTPUT V3 DC OUTPUT V1 DC OUTPUT COM DC OUTPUT V2 DC Output Connector (CN2) : JST S6B-XH-A-1 or equivalent 6-M4 L=6mm RECTIFIERS & FILTER RECTIFIERS & FILTER V2 +5V COM COSTANT CURRENT & DETECTION CIRCUT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 QP-200-3A 70 70 LOAD(%) 60 LOAD (%) 135 V2 V1 ADJ. 6 40 20 -10 -10 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 (HORIZONTAL) 60 50 40 90 100 115 135 155 230 264 INPUT VOLTAGE (VAC) 60Hz File Name:QP-200-SPEC 2008-07-08