MEANWELL QP-200F

QP-200
200W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH1,2 can be adjustable from -5~+10%
With power good and fail signal output(Optional)
Built-in remote sense function for CH1,2
100% full load burn-in test
CH4 can set to positive after consult us before delivery(Optional)
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
..
SPECIFICATION
QP-200D
MODEL
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
12V
24V
-12V
5V
15V
24V
-15V
5V
3.3V
12V
-5V
RATED CURRENT
5V
15A
4A
3A
0.7A
15A
3A
3A
0.7A
15A
15A
6A
0.7A
CURRENT RANGE
3 ~ 20A
0 ~ 6A
0.4 ~ 5A
0 ~ 1A
3 ~ 20A
0 ~ 5A
0.4 ~ 5A
0 ~ 1A
3 ~ 20A
0 ~ 20A
0.5 ~ 8A
0 ~ 1A
7A
6A
1A
6A
6A
1A
20A
8A
1A
PEAK CURRENT
203.4W
Note.4 20A
202.5W
20A
200W
20A
RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
CH2: 14.25 ~ 16.5V CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3
CH1: 4.75 ~ 5.5V
3.0%
3.0%
+10,-6%
6.0%
3.0%
3.0%
+10,-6%
6.0%
3.0%
3.0%
+8,-10%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
6.0%
24ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
CH2: 11.4 ~ 13.2V
800ms, 50ms at full load
SETUP, RISE TIME
INPUT
QP-200-3A
CH1
RATED POWER
OUTPUT
QP-200F
OUTPUT NUMBER
Note.6 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
75%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3.5A/115VAC
2A/230VAC
COLD START 30A
PF>0.98/115VAC at full load
75%
72%
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
CH1:5.75 ~ 6.75V
CH2:13.8 ~ 16.2V CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
95
5
CH2:17.25 ~ 20.25V CH1:5.75 ~ 6.75V
CH2:3.8 ~ 4.4V
(TSW1) detect on heatsink of Q1,Q2 power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 5)
OTHERS
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
160.6K hrs min.
DIMENSION
215*115*50mm (L*W*H)
1.2Kg; 12pcs/15.4Kg/0.92CUFT
PACKING
NOTE
20 ~ 90% RH non-condensing
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-200-SPEC 2008-07-08
QP-200
200W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH1,2 can be adjustable from -5~+10%
With power good and fail signal output(Optional)
Built-in remote sense function for CH1,2
100% full load burn-in test
CH4 can set to positive after consult us before delivery(Optional)
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
..
SPECIFICATION
QP-200-3B
MODEL
CH2
CH3
CH4
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
3.3V
12V
-12V
5V
3.3V
15V
-15V
5V
3.3V
24V
-12V
RATED CURRENT
15A
15A
6A
0.7A
15A
15A
5A
0.7A
10A
15A
4A
0.7A
CURRENT RANGE
3 ~ 20A
0 ~ 20A
0.5 ~ 8A
0 ~ 1A
3 ~ 20A
0 ~ 20A
0.5 ~ 6A
0 ~ 1A
3 ~ 15A
0 ~ 20A
0.4 ~ 5A
0 ~ 1A
20A
8A
1A
20A
20A
7A
1A
20A
20A
6A
1A
204.9W
RATED POWER
Note.4 20A
210W
203.9W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
CH1: 4.75 ~ 5.5V
VOLTAGE ADJ. RANGE
CH2: 3.14 ~ 3.63V
CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
CH1: 4.75 ~ 5.5V
CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3
3.0%
3.0%
+8,-10%
6.0%
3.0%
3.0%
+10,-6%
6.0%
3.0%
3.0%
+10,-6%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
2.0%
2.0%
6.0%
2.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
24ms at full load
VOLTAGE RANGE
INPUT
QP-200-3D
CH1
PEAK CURRENT
OUTPUT
QP-200-3C
OUTPUT NUMBER
Note.6 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC
EFFICIENCY (Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3.5A/115VAC
2A/230VAC
COLD START 30A
PF>0.98/115VAC at full load
72%
74%
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
6.0%
CH1:5.75 ~ 6.75V
CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW1) detect on heatsink of Q1,Q2 power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
OVER TEMPERATURE
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
OTHERS
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
160.6K hrs min.
DIMENSION
215*115*50mm (L*W*H)
1.2Kg; 12pcs/15.4Kg/0.92CUFT
PACKING
NOTE
20 ~ 90% RH non-condensing
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-200-SPEC 2008-07-08
QP-200
200W Quad Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
CH1,2 can be adjustable from -5~+10%
With power good and fail signal output(Optional)
Built-in remote sense function for CH1,2
100% full load burn-in test
CH4 can set to positive after consult us before delivery(Optional)
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
..
SPECIFICATION
QP-200-3E
MODEL
OUTPUT NUMBER
CH1
CH2
CH3
DC VOLTAGE
3.3V
24V
-15V
RATED CURRENT
5V
10A
15A
4A
0.7A
CURRENT RANGE
3 ~ 15A
0 ~ 20A
0.4 ~ 5A
0 ~ 1A
RATED POWER
206W
20A
6A
1A
100mVp-p
150mVp-p
150mVp-p
PEAK CURRENT
OUTPUT
Note.4 20A
RIPPLE & NOISE (max.) Note.2 100mVp-p
CH1: 4.75 ~ 5.5V
VOLTAGE ADJ. RANGE
CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3
3.0%
3.0%
+10,-6%
6.0%
LINE REGULATION
1.0%
1.0%
2.0%
1.0%
LOAD REGULATION
2.0%
2.0%
6.0%
2.0%
800ms, 50ms at full load
SETUP, RISE TIME
24ms at full load
HOLD TIME (Typ.)
VOLTAGE RANGE
Note.6 90 ~ 264VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
CH4
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
47 ~ 63Hz
PF>0.95/230VAC
74%
3.5A/115VAC
127 ~ 370VDC
PF>0.98/115VAC at full load
2A/230VAC
COLD START 30A
LEAKAGE CURRENT
<2mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
CH1:5.75 ~ 6.75V
CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW1) detect on heatsink of Q1,Q2 power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION POWER GOOD / POWER FAIL(OPTIONAL) 10ms/1ms
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
OVER TEMPERATURE
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 5)
OTHERS
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
160.6K hrs min.
DIMENSION
215*115*50mm (L*W*H)
1.2Kg; 12pcs/15.4Kg/0.92CUFT
PACKING
NOTE
MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-200-SPEC 2008-07-08
QP-200
200W Quad Output with PFC Function
Mechanical Specification
Case No. 912B
series
Unit:mm
117.5
32.5
150
27.5
177.5
LED
115
95
50
4-M4 L=5mm
5-M3 L=3mm
10
50.5
47.5
16
8
9.5
9
8
7
6
5
4
3
2
1
32.5
1
36.5
CN2
15
Terminal Pin No. Assignment
Pin No. Assignment
Pin No.
1
5
AC/L
AC/N
2
6
3
FG
7,8
DC OUTPUT V4
4
9
Air flow
direction
215
150
32.5
51.5
50
CL
25
13 max.
Terminal
Pin No. Assignment Pin No. Assignment Mating Housing
V1(+S)
V2(-S)
1
4
JST SXH-001T-P0.6
JST XHP
V1(-S)
PF/PG
2
5
or equivalent
or equivalent
V2(+S)
GND
3
6
PFC fosc : 67KHz
PWM fosc : 134KHz
RECTIFIERS
&
FILTER
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
REGULATOR
V4
FAN
RECTIFIERS
&
FILTER
V3
MA
&
CONTROL
PWM & PFC
CONTROL
FG
Assignment
DC OUTPUT V3
DC OUTPUT V1
DC OUTPUT COM
DC OUTPUT V2
DC Output Connector (CN2) : JST S6B-XH-A-1 or equivalent
6-M4 L=6mm
RECTIFIERS
&
FILTER
RECTIFIERS
&
FILTER
V2
+5V
COM
COSTANT CURRENT
&
DETECTION CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
100
90
80
80
QP-200-3A
70
70
LOAD(%)
60
LOAD (%)
135
V2
V1
ADJ.
6
40
20
-10
-10
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
60
50
40
90
100
115
135
155
230 264
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-200-SPEC 2008-07-08