MPD MDR-24S-05

MDR-24S Series
Low Cost, 24W
New Industrial
DIN Rail Mount
Supplies!!
Single Output
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 24W Output Power
• DIN Rail Mountable
• Universal AC Input
• Narrow 0.886” Case
• EN60950 Compliant
• 5, 12, & 24 VDC Outputs
• Meets EN55022 Class B
• >200 kH MTBF
• LOW COST!
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Universal
Input Voltage Range
Input Frequency
Input Undervoltage Lockout
Min.
85
120
47
72
110 VAC
220 VAC
Inrush Current, Cold Start
Typ.
Max.
264
370
63
88
Units
VAC
VDC
Hz
VAC
A
A
Max.
Units
%
%
%
mSec
mV P-P
16
30
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation (Note 1)
Hold Time
Ripple & Noise (20 MHz) (Note 2)
Over Current Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±0.5
Vin = ±10%
±0.1
Iout = 10% to 100%
±1.0
230 VAC, Full Load
80
50
MDR-24-05S
4.4
MDR-24-12S
2.4
MDR-24-24S
1.3
±0.02
Continuous With Autorecovery
A
%/ºC
General
Parameter
Isolation Voltage
Switching Frequency
Conditions
Input - Output
Min.
3,000
60
Typ.
Max.
100
Units
VAC
kHz
Max.
+70
+85
Units
ºC
ºC
95
%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Power Derating
Humidity
Conditions
Min.
Typ.
-25
+25
-25
3.75%/ ºC Above 55ºC
RH, Non-condensing
Ambient
Physical
Case Size
Case Material
Case Protection
Connection
Mounting
3.99 x 4.51 x 0.886 Inches (99.0 x 114.5 x 22.5 mm)
Green Plastic
IP20
Screw Terminal
35 mm DIN Rail
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
EMI Compliance
EMS Immunity Compliance
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
Units
200
kHours
Meets UL 1950, EN 60950, IEC 60950
Class 1
Compliance to EN55011, EN55022 (CISPR22) Class B
Electrostatic Discharge (ESD)
EN6100-4-2, 4kV/8 kV
RF Field Susceptibility
EN6100-4-3, 3V/m
Fast Transients/Bursts On Mains Line
EN6100-4-4, 2 kV
Surge
EN6100-4-5, Level 3, 1 kV/2 kV
Model Selection Guide
Model
Number
Rated
Power
(W)
MDR-24S-05
MDR-24S-12
MDR-24S-24
20
24
24
Input
Output
Voltage (VAC)
Current (A)
Voltage Current (A)
Max)
Universal Range 115 VAC 230 VAC (VDC)
100 - 240
0.45
0.22
5
4.0
100 - 240
0.45
0.22
12
2.0
100 - 240
0.45
0.22
24
1.0
Notes:
1. Load regulation is specified for a load
change of 20% to 100%.
2. Overload protection is current limiting.
The unit recovers automatically when
the fault is removed.
3. Over voltage protection is a shut down
type. The unit recovers automatically
when the fault is removed.
4. The MDR-24 meets class 1 safety
requirements with a proper PE connection. To insure compliance to
EN60950, it must be possible to switch
off the unit using suitable disconnection device external to the power
supply.
5. It is recommended that a fuse be used
on the input of a power supply for
protection. For the MDR-24 series, a
250 VAC 3.15A is recommended.
Overvoltage
Protection
(VDC)
6.5
20.0
30.0
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(A)
75
85
87
3.15
3.15
3.15
Input Connection
Mounting and Airflow
The MDR-24 series may be connected to single
or three-phase AC networks as shown. All wires
should be 14-25 AWG. For safety, all wires
should be stripped approximately 7 mm. and
any connections to the supply should only be
made with the system power off. Do not operate without a proper PE connection.
To allow proper ventilation, the MDR-24 series should be mounted
so they are vertically orientated with approximately 2 inches (50
mm) of clearance above and below the unit. No minimum spacing
is required between units. Ventilation holes should not be covered
and proper derating should be followed.
Connections
Pin
Function
1, 2
DC Output (+V)
3, 4
DC Output (-V)
5, 6
Earth (PE)
7
AC/Neutral (N-)
8
AC/Line (L+)
Mechanical Dimensions
Installation/Removal
Install
To mount the unit to
the DIN rail, tilt the unit
rearwards from the top,
fitting the mount over
the top of the rail. Press
back on the bottom
front of the unit until
it locks in place on the
rail.
Remove
To remove the unit
from the rail, pull the
removal clip at the
bottom rear of the
unit downward with
a screw driver. With
the clip down, lift up
on the unit from the
bottom front until it
clears the rail.
Before installation
or removal all wiring
should be disconnected
and the main power to
the system shut off.
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensio
dimensions are typical in inches (mm)
• Tolerance x.
x.xx = ±0.01 (±0.25)
FAX: (781) 344-8481
•
E-Mail: [email protected]