MPD DRT-960

DRT-960 Series
Low Cost, Three-Phase
960W, DIN Rail Mount
AC/DC Power Supplies
New
Industrial
Supplies!!
Electrical Specifications
Specifications typical @ +25°C, 400 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Input Voltage Range
• 960W Output Power
• DIN Rail Mountable
Input Frequency Range
• Three-Phase, 4-Wire Input Inrush Current
• UL 508 Approved
Leakage Current
• UL 60950 & EN 60950 App. Output
• 24 VDC & 48 VDC Outputs Parameter
• Cond./Rad. EMI Class B
Output Voltage Accuracy
• >122 kH MTBF
Voltage Adjustment Range
• LOW COST!
Line Regulation
Load Regulation
Set Up Time
Rise Time
Hold Time
Ripple & Noise (Note 2)
Output Power Protection
Over Voltage Protection (Note 4)
Over Temperature Protection
Temperature Coefficient
General
Parameter
Isolation Voltage
RoHS Compliant
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Isolation Resistance (Note 6)
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
Vibration
Physical
Case Size
Case Material
Connection
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
EMI Compliance
Harmonic Current Compliance
EMS Immunity Compliance
Conditions
Min.
340
480
47
Cold Start
530 VAC
Conditions
3.5
Conditions
Input - Output
Input - FG (Frame Ground)
Output - FG (Frame Ground)
500 VDC
Typ.
±1.0
24
48
Max.
28
55
±0.5
±0.5
200
200
60
14
30
Iout = 10% to 100%
At Full Load, 400 VAC Input
At Full Load, 500 VAC Input
At Full Load
At Full Load, 400 VAC Input
At Full Load, 500 VAC Input
Note 3
24 VDC Output
48 VDC Output
TSW1 Note 5
TSW2 Note 5
0ºC to 50ºC
Max.
555
780
63
50
Min.
Note 1
24 VDC Output
48 VDC Output
Typ.
105
30
59
105
80
Min.
3,000
1,500
500
100
110
85
±0.03
Typ.
Units
VAC
VDC
Hz
A
mA
Units
%
VDC
%
%
mSec
mSec
mSec
80
150
36
66
115
90
mV Pk-Pk
%
VDC
ºC
%/ºC
Max.
Units
VAC
MΩ
Conditions
Min.
Typ.
Max.
Units
-20
+25
+60
ºC
-40
+85
ºC
RH, Non-condensing
20
90
%
RH, Non-condensing
10
95
%
10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour
Ambient
10.87 x 4.94 x 3.94 Inches (125.5 x 125.5 x 100.0 mm)
Aluminum
Screw Terminal
117.7 Oz (3.3 kg)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
Units
122.5
kHours
UL 508, UL 60950, EN 60950-1
UL, cUL, TUV
Compliance to EN55011, EN55022 (CISPR22) Class B
Compliance to EN6100-3-2,-3
EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Model Selection Guide
Model
Number
Rated
Power
(W)
DRT-960-24
DRT-960-48
Input
Output
Voltage
(VAC)
Range
400 VAC
500 VAC
960
340 - 555
2.0
1.6
24
40
960
340 - 555
2.0
1.6
48
20
Current (A)
Notes:
1. Output voltage tolerance includes set-up tolerance, line regulation and load regulation.
2. Ripple & noise is measured using equipment with 20 Mhz of
bandwidth. Connection to the unit under test is made with a
12 inch length of “twisted pair” wires terminated with a set of
1.0 μF & 4.7 μF capacitors connected in parallel.
3. Overload protection is foldback current limiting. The unit recovers automatically when the fault is removed.
4. Over voltage protection is a clamp type. The power to the unit
must be manually reset to recover.
5. Over temperature protection shuts down the output. The unit
recovers automatically when the temperature goes down. For
TSW1, the thermal detector is mounted on the heat sink of
the power semiconductor. For TSW2, the thermal detector is
mounted on the heat sink of the power Diode.
6. Isolation resistance is given for Input/Output; Input/FG and
Output/FG.
7. To mount the unit to the DIN rail, tilt the unit rearwards from
the top, fitting the mount over the top of the rail. Press back
on the bottom front of the unit until it locks in place on the rail.
To remove the unit from the rail, pull the removal clip at the
bottom rear of the unit downward with a screw driver. With
the clip down, lift up on the unit from the bottom front until it
clears the rail. Before installation or removal all wiring should
be disconnected and the main power to the system shut off.
8. When wiring the supply, all lines should be as thick and short as
possible. AWG 14 wire is recommended for the DRT-960 series.
9. The units should be mounted so they are vertically orientated.
Air flow (if it is provided) would optimally flow from the bottom
to the top of the unit.
10. It is recommended that a fuse be used on the input of a power
supply for protection. See the table above for the correct
rating.
Voltage
(VDC)
Current (A)
Max)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(A)
0 ~ 40
91
6.3
0 ~ 20
92
6.3
Current (A)
Range
Derating Curve - Output Power vs Ambient Temperature
Static Characteristics
Mechanical Dimensions
Terminal Connections - TB1
Pin
Function
1
AC/Lve 1
2
AC/Lve 2
3
AC/Live 3
4
Frame Ground (FG)
Terminal Connections - TB2
Pin
Function
1,2
DC Output (+V)
3,4
DC Output (-V)
Mechanical Notes:
• All dimensions are typical in
inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•