MPD DR-120-24

DR-120 Series
Low Cost, Industrial
120W, DIN Rail Mount
AC/DC Power Supplies
New Industrial
Supplies!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 120W Output Power
• DIN Rail Mountable
• Selectable AC Input
• UL 508 Approved
• Safety Approved
• 12, 24 & 48 VDC Outputs
• Cond./Rad. EMI Class B
• >136 kH MTBF
• LOW COST!
Input
Parameter
Input Voltage Range
Inrush Current
Leakage Current
Output
Parameter
Output Voltage Tolerance
Line Regulation
Load Regulation
Set Up Time
Rise Time
Hold Time
Ripple & Noise (Note 2)
Output Power Protection
Over Voltage Protection (Note 4)
Over Temperature Protection (Note 5)
Temperature Coefficient
Switching Frequency
General
Parameter
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
AC Input Selected by Switch On Front Panel
Input Frequency Range
Voltage Adjustment Range
RoHS Compliant
Conditions
Isolation Voltage
Isolation Resistance (Note 6)
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
Vibration
Physical
Case Size
Case Material
Connection
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
EMI Compliance
Harmonic Current Compliance
EMS Immunity Compliance
Min.
88
176
248
47
230 VAC, Cold Start
115 VAC, Cold Start
240 VAC
Conditions
Iout = 10% to 100%
At Full Load
At Full Load
230 VAC, Full Load
115 VAC, Full Load
12 VDC Output
24 VDC Output
48 VDC Output
Note 3
12 VDC Output
24 VDC Output
48 VDC Output
12 VDC Output
24 & 48 VDC Output
0ºC to 50ºC
Fixed
Conditions
Input - Output
Input - FG (Frame Ground)
Output - FG (Frame Ground)
500 VDC
Max.
132
264
370
63
Units
3.5
mA
Max.
Units
%
40
20
Min.
Note 1
12 VDC Output
24 VDC Output
48 VDC Output
Typ.
Typ.
±1.0
12
24
48
A
14
28
53
±0.5
±1.0
500
70
36
32
105
15
29
58
80
85
Min.
3,000
1,500
500
100
85
90
±0.03
55
Typ.
VAC
VDC
Hz
VDC
%
%
mSec
mSec
mSec
80
80
100
150
16.5
33
65
90
95
mV Pk-Pk
%
VDC
ºC
%/ºC
kHz
Max.
Units
VAC
MΩ
Conditions
Min.
Typ.
Max.
Units
-10
+25
+60
ºC
-20
+85
ºC
RH, Non-condensing
20
90
%
RH, Non-condensing
10
95
%
10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour
Ambient
2.60 x 4.93 x 3.94 Inches (65.5 x 125.5 x 100.0 mm)
Aluminum
Screw Terminal
28 Oz (0.79 kg)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
Units
136.8
kHours
UL 508, UL 60950, EN 60950-1
UL, cUL, TUV
Compliance to EN55011, EN55022 (CISPR22) Class B
Compliance to EN6100-3-2,-3
EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Model Selection Guide
Model
Number
DR-120-12
DR-120-24
DR-120-48
Rated
Power
(W)
120
120
120
Input
Voltage (VAC)
Output
Current (A)
Range
88 - 132 / 176 - 264
88 - 132 / 176 - 264
88 - 132 / 176 - 264
115 VAC
2.6
2.6
2.6
Voltage
(VDC)
230 VAC
1.6
1.6
1.6
Notes:
1. Output voltage tolerance includes set-up tolerance, line regulation and
load regulation. For the 12V output model, tolerance is ±2.0%.
2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth.
Connection to the unit under test is made with a 12 inch length of “twisted
pair” wires terminated with a set of 1.0 μF & 4.7 μF capacitors connected
in parallel.
3. Overload protection is foldback current limiting. The unit recovers automatically when the fault is removed.
4. Over voltage protection is a clamp type. The power to the unit must be
manually reset to recover.
5. Over temperature protection shuts down the output. The unit recovers
automatically when the temperature goes down. The thermal detector
is mounted on the heat sink of the power semiconductor.
6. Isolation resistance is given for Input/Output; Input/FG and Output/FG.
7. To mount the unit to the DIN rail, tilt the unit rearwards from the top,
fitting the mount over the top of the rail. Press back on the bottom front
of the unit until it locks in place on the rail. To remove the unit from the
rail, pull the removal clip at the bottom rear of the unit downward with
a screw driver. With the clip down, lift up on the unit from the bottom
front until it clears the rail. Before installation or removal all wiring should
be disconnected and the main power to the system shut off.
8. When wiring the supply, all lines should be as thick and short as possible.
AWG 14 wire is recommended for the DR-120 series.
9. The units should be mounted so they are vertically orientated. Air flow
(if it is provided) would optimally flow from the bottom to the top of
the unit.
10. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
12
24
48
Current (A)
Max)
10.0
5.0
2.5
Current (A)
Range
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(A)
80
84
85
5.0
5.0
5.0
0 ~ 10.0
0 ~ 5.0
0 ~ 2.5
Derating Curve - Output Power vs Ambient Temperature
Static Characteristics (24 Vout)
Mechanical Dimensions
Terminal Connections - TB1
Pin
Function
1
Frame Ground (FG)
2
AC/Neutral (DC+)
3
AC/Live (DC-)
Terminal Connections - TB2
Pin
Function
1,2
DC Output (+V)
3,4
DC Output (-V)
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]