MPD DR-45-05

DR-45
Series
Low Cost, Industrial
45W, DIN Rail Mount
AC/DC Power Supplies
New Industrial
Supplies!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Voltage Adjustment Range
Line Regulation
Load Regulation
Set Up Time
Rise Time
Hold Time
Ripple & Noise (Note 2)
Output Power Protection
Over Voltage Protection (Note 4)
Over Temperature Protection
Temperature Coefficient
Switching Frequency
General
Parameter
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
85
120
47
Input Voltage Range
• 45W Output Power
Input Frequency Range
• DIN Rail Mountable
• Universal AC Input
Inrush Current
• UL 508 Approved
Leakage Current
• Safety Approved
Output
• 5, 12, 15 & 24 VDC Outputs Parameter
• Cond./Rad. EMI Class B
Output Voltage Tolerance
• >364 kH MTBF
• LOW COST!
RoHS Compliant
Conditions
Isolation Voltage
Isolation Resistance (Note 6)
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
Vibration
Physical
Case Size
Case Material
Connection
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
EMI Compliance
Harmonic Current Compliance
EMS Immunity Compliance
230 VAC, Cold Start
115 VAC, Cold Start
240 VAC
Conditions
Typ.
±1.0
4.75
10.8
13.5
21.6
Iout = 10% to 100%
230 VAC, Full Load
At Full Load
230 VAC, Full Load
5 VDC Output
12 VDC Output
15 VDC Output
24 VDC Output
Note 3 105
5 VDC Output 5.75
12 VDC Output 13.8
15 VDC Output 17.25
24 VDC Output 27.6
Note 5
0ºC to 50ºC
Fixed
Conditions
Input - Output
Input - FG (Frame Ground)
Output - FG (Frame Ground)
500 VDC
Max.
264
370
63
56
28
Min.
Note 1
5 VDC Output
12 VDC Output
15 VDC Output
48 VDC Output
Typ.
Min.
3,000
1,500
500
100
A
1.0
mA
Max.
Units
%
5.5
13.2
16.5
26.4
±1.0
±1.0
800
60
100
VDC
%
%
mSec
mSec
mSec
100
200
240
480
150
6.75
16.2
20.25
32.4
135
±0.03
100
Typ.
Units
VAC
VDC
Hz
mV Pk-Pk
%
VDC
ºC
%/ºC
kHz
Max.
Units
VAC
MΩ
Conditions
Min.
Typ.
Max.
Units
-10
+25
+50
ºC
-20
+85
ºC
RH, Non-condensing
20
90
%
RH, Non-condensing
10
95
%
10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour
Ambient
3.66 x 3.05 x 2.64 Inches (93.0 x 78.0 x 67.0 mm)
Plastic (UL94-V0)
Screw Terminal
11 Oz (0.31 kg)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
Units
364.6
kHours
UL 508, UL 60950, EN 60950-1
UL, cUL, TUV
Compliance to EN55011, EN55022 (CISPR22) Class B
Compliance to EN6100-3-2,-3
EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Model Selection Guide
Model
Number
Rated
Power
(W)
DR-45-05
DR-45-12
DR-45-15
DR-45-24
25
42
42
48
Input
Voltage
(VAC)
Range
85 - 264
85 - 264
85 - 264
85 - 264
Output
Current (A)
115 VAC
1.5
1.5
1.5
1.5
230 VAC
0.75
0.75
0.75
0.75
Voltage
(VDC)
Current (A)
Max)
5
12
15
24
Current (A)
Range
5.0
3.5
2.8
2.0
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(A)
72
77
77
80
5.0
5.0
5.0
5.0
0 ~ 5.0
0 ~ 3.5
0 ~ 2.8
0 ~ 2.0
Mechanical Dimensions
Notes:
1. Output voltage tolerance includes set-up tolerance,
line regulation and load regulation.
2. Ripple & noise is measured using equipment with 20
Mhz of bandwidth. Connection to the unit under test
is made with a 12 inch length of “twisted pair” wires
terminated with a set of 1.0 μF & 4.7 μF capacitors
connected in parallel.
3. Overload protection is foldback current limiting.
The unit recovers automatically when the fault is
removed.
4. Over voltage protection is a shut down type. The
power to the unit must be manually reset to recover.
5. Over temperature protection shuts down the output.
The unit recovers automatically when the temperature goes down. The thermal detector is mounted on
the heat sink of the power semiconductor.
6. Isolation resistance is given for Input/Output; Input/FG
and Output/FG.
7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top
of the rail. Press back on the bottom front of the unit
until it locks in place on the rail. To remove the unit
from the rail, pull the removal clip at the bottom rear
of the unit downward with a screw driver. With the
clip down, lift up on the unit from the bottom front
until it clears the rail. Before installation or removal all
wiring should be disconnected and the main power
to the system shut off.
8. When wiring the supply, all lines should be as thick
and short as possible. AWG 14 wire is recommended
for the DR-45 series.
9. The units should be mounted so they are vertically
orientated. Air flow (if it is provided) would optimally
flow from the bottom to the top of the unit.
10. It is recommended that a fuse be used on the input
of a power supply for protection. See the table
above for the correct rating.
Terminal Connections
Pin
1
Function
Pin
AC/Live (DC-)
6,7
Function
Mechanical Notes:
DC Output (+V)
2
AC/Neutral (DC+)
8
LED
3
Frame Ground (FG)
9
+VAdj
4,5
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
DC Output (-V)
Static Characteristics (24 Vout)
Derating Curve - Output Power vs Ambient Temp.
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]