MPD DRP-240-24

DRP-240 Series
Low Cost, Industrial
240W, DIN Rail Mount
AC/DC Power Supplies
New
Industrial
Supplies!!
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
Parameter
Input Voltage Range
• 240W Output Power
• DIN Rail Mountable
Input Frequency Range
• Universal AC Input
Power Factor
• UL 508 Approved
• 0.99 Power Factor Corr.
Inrush Current
• 24 VDC & 48 VDC Outputs
• Cond./Rad. EMI Class B
Leakage Current
Output
• >100 kH MTBF
Parameter
• LOW COST!
Output Voltage Accuracy
Voltage Adjustment Range
Line Regulation
Load Regulation
Set Up Time
Rise Time
Hold Time
Ripple & Noise (Note 2)
Output Power Protection
Over Voltage Protection (Note 4)
Over Temperature Protection
Temperature Coefficient
Switching Frequency
General
Parameter
Isolation Voltage
RoHS Compliant
MicroPower Direct
232 Tosca Drive
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Isolation Resistance (Note 6)
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Storage Humidity
Vibration
Physical
Case Size
Case Material
Connection
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
EMI Compliance
Harmonic Current Compliance
EMS Immunity Compliance
Conditions
Min.
85
120
47
230 VAC, Full Load
115 VAC, Full Load
230 VAC, Cold Start
115 VAC, Cold Start
240 VAC
Conditions
Iout = 10% to 100%
At Full Load
At Full Load
At Full Load
24 VDC Output
48 VDC Output
Note 3
24 VDC Output
48 VDC Output
Note 5
0ºC to 50ºC
Fixed
Conditions
Input - Output
Input - FG (Frame Ground)
Output - FG (Frame Ground)
500 VDC
Max.
264
370
63
0.96
0.99
45
27
Min.
Note 1
24 VDC Output
48 VDC Output
Typ.
Typ.
±1.0
24
48
A
3.5
mA
Max.
Units
%
28
53
±0.5
±1.0
800
40
24
105
30
54
95
Min.
3,000
1,500
500
100
100
±0.03
100
Typ.
Units
VAC
VDC
Hz
VDC
%
%
mSec
mSec
mSec
80
150
150
36
60
105
Max.
mV Pk-Pk
%
VDC
ºC
%/ºC
kHz
Units
VAC
MΩ
Conditions
Min.
Typ.
Max.
Units
-10
+25
+70
ºC
-20
+85
ºC
RH, Non-condensing
20
90
%
RH, Non-condensing
10
95
%
10 ~ 500 Hz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour
Ambient
4.94 x 4.93 x 3.94 Inches (125.5 x 125.5 x 100.0 mm)
Aluminum
Screw Terminal
42.8 Oz (1.2 kg)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
Units
105.5
kHours
UL 508, UL 60950, EN 60950-1
UL, cUL, TUV
Compliance to EN55011, EN55022 (CISPR22) Class B
Compliance to EN6100-3-2,-3
EN6100-4-2,3,4,5,6,8,11; ENV50204;EN6100-6-2(EN50082-2) Heavy Ind. Level, criteria A
Model Selection Guide
Model
Number
Rated
Power
(W)
DRP-240-24
DRP-240-48
Input
Output
Voltage
(VAC)
Range
115 VAC
230 VAC
240
85 - 264
2.8
1.4
24
10
240
85 - 264
2.8
1.4
48
5
Current (A)
Voltage
(VDC)
Notes:
1. Output voltage tolerance includes set-up tolerance, line regulation and
load regulation.
2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth.
Connection to the unit under test is made with a 12 inch length of “twisted
pair” wires terminated with a set of 1.0 μF & 4.7 μF capacitors connected
in parallel.
3. Overload protection is foldback current limiting. The unit recovers automatically when the fault is removed.
4. Over voltage protection is a clamp type. The power to the unit must be
manually reset to recover.
5. Over temperature protection shuts down the output. The unit recovers
automatically when the temperature goes down. The thermal detector
is mounted on the heat sink of the power semiconductor.
6. Isolation resistance is given for Input/Output; Input/FG and Output/FG.
7. To mount the unit to the DIN rail, tilt the unit rearwards from the top,
fitting the mount over the top of the rail. Press back on the bottom front
of the unit until it locks in place on the rail. To remove the unit from the
rail, pull the removal clip at the bottom rear of the unit downward with
a screw driver. With the clip down, lift up on the unit from the bottom
front until it clears the rail. Before installation or removal all wiring should
be disconnected and the main power to the system shut off.
8. When wiring the supply, all lines should be as thick and short as possible.
AWG 14 wire is recommended for the DRP-240 series.
9. The units should be mounted so they are vertically orientated. Air flow
(if it is provided) would optimally flow from the bottom to the top of
the unit.
10. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Current (A)
Max)
Efficiency
(%, Typ)
Fuse Rating
Slow-Blow
(A)
0 ~ 10
84
6.3
0~5
85
6.3
Current (A)
Range
Derating Curve - Output Power vs Ambient Temperature
Derating Curve - Output Power vs Input Voltage
Mechanical Dimensions
Terminal Connections - TB1
Pin
Function
1
Frame Ground (FG)
2
AC/Neutral
3
AC/Live
Terminal Connections - TB2
Pin
Function
1,2
DC Output (+V)
3,4
DC Output (-V)
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
232 Tosca Drive Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]