HBU31 SERIES 30W Open Frame Type Medical Power Supplies For Health Care Applications Description: The HBU31 series of compact, open frame constructed, AC/DC switching mode power supplies provide 30 Watts of continuous output power .They are suited for use in Health care applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark(EN 60601-1:2ndEdition) and new CE requirements. All units are 100% burned in and tested. Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz Internal EMI filter Single Output Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal Output connector mates with Molex housing 09-50-3041 and Molex 2478 series crimp terminal Input Surge Current, Over Voltage and Over Load protection Size: 1.5"x4”x0.83” Class II 2 year warranty Safety Approvals : CB Electrical Characteristics: Sym. Parameter fin Po Vo Io Iil Iih Safety Approvals Input Voltage Range Operate Voltage Range Input Frequency Output Power Range Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) I rl Low Line Inrush Current Vin I rh Eff REG-i REG -o OCP Ttr Thold Ts Vp-p Ilk TC High Line Inrush Current Efficiency Line Regulation Load Regulation Over Current Protection Time of Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient Test Conditions Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, Io=Full load Vin=230VAC Vin=115VAC Vin=230VAC 25 C,Cool start, IEC 60601-1 Min. Typ. Max. Unit 240 100 Vin=90 to 264 VAC EN 60601-1 264 90 47 63 30 0 See rating Chart See rating Chart 0.8 0.3 0.4 VAC VAC Hz W V A A A A 15 18 25 40 A 85 0.5 3 89 1 5 150 4 110 Io=Full load to Half Load, Vin=100VAC 12 18 Io=Full load, Vin=110VAC Io=Full load, Vin=100VAC 0.25 0.5 Full load, Vin=90VAC 0.5 1 Io=Full load, Vin=240VAC 0.1 0.3 All output -0.04 0.04 % % % % mS mS S % mA %/ C Min. Typ. Max. Unit 40 70 C 25 C,Cool start, Vin=230VAC 75 Environmental : Sym. Parameter T e s t Conditions Toper Operating Temperature Tstg Storage Temperature -40 85 C Ho Operating Humidity 0 95 % Hr Storage Humidity 0 75 % MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 40 C to 50% load at 70 C 0 0.1M Hrs HBU31 SERIES 30W Open Frame Type Medical Power Supplies For Health Care Applications Safety Specifications: Sym. Parameter Dielectric Withstanding Voltage for Primary to secondary CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Vps T e s t Conditions Primary to secondary Min. Typ. Max. Unit 5656 VDC B B CLASS CLASS Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Model Number Output Voltage Output Current Total Regulation Maximum Output Power HBU31-102 05 ~ 06 VDC 4.00 ~ 3.33 A 5% 20W HBU31-103 06 ~ 08 VDC 3.83 ~ 2.87 A 5% 23W HBU31-104 8 ~ 11 VDC 3.37 ~ 2.45 A 5% 27W HBU31-105 11 ~ 13 VDC 2.72 ~ 2.31 A 5% 30W HBU31-106 13 ~ 16 VDC 2.31 ~ 1.88 A 5% 30W HBU31-107 16 ~ 21 VDC 1.88 ~ 1.43 A 5% 30W HBU31-108 21 ~ 27 VDC 1.43 ~ 1.12 A 3% 30W HBU31-109 27 ~ 33 VDC 1.12 ~ 0.91 A 3% 30W HBU31-110 33 ~ 40 VDC 0.91 ~ 0.76 A 3% 30W Mechanical Specifications : L N Note: 1. Dimensions are shown in inches or mm. 2. Weight: 85gs approx. 3. Input connector mates with Molex housing 09-50-3031 and Molex 2478 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3041 and Molex 2478 series crimp terminal. 1 4