HPU12A SERIES 12W Wall mount type medical power supplies For Home health care applications Description: The HPU12A series of AC/DC switching mode power supplies provide 12 watts of continuous output power. This series is suitable for use in Home health care and portable applications. All models meet FCC Part-18 class B and CISPR11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1) ,TUV/T-mark(EN 60601-1) and new CE requirements. Features: Wide Input Voltage 90 to 264 VAC,47 to 63 Hz 2 Prong Plug-In Mains Connector Output Voltage Available From 5VDC Thru 27VDC Optional Output Connector (See appendix) Single Output Safety Approvals: Class II CEC level V and Engergy Star 2.0 Compliance Over Load protection. 2 year warranty Electrical Characteristics: Sym. Parameter Vin fin Po Input Voltage Input Frequency Output Power Range Vo Io Iil Iih Output Voltage Range Output Current Range Input Current (Low Line) Input Current (High Line) Irl Low Line Inrush Current Irh High Line Inrush Current Eff Efficiency Test Conditions Operating Voltage Vin=90 to 264VAC Io=Full load, Io=Full load, Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full Load, Vin=115VAC Vin=230VAC 25 c, Cool start, Min. Unit 264 63 12 VAC Hz W See rating chart See rating chart 0.25 0.35 0.17 0.22 V A A A 14 16 A 28 30 A 25 c, Cool start, Vin=230VAC Typ. Max. 90 47 0 77.7 % REG-i Line Regulation Io=Full Load 1 % REG-o Load Regulation Vin=230VAC 5 % OCP Over Current Protection Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC Thold Hold-Up Time 110 Io=Full Load, Vin=110VAC 10 Ts Start Up Time Io=Full Load, Vin=100VAC 0.3 Vrn Ripple & Noise(Peak to Peak) Full Load, Vin=90VAC TC Temperature Coefficient All output The parameter is not subject to production test-verified by design/characterization of integrated controller. Tjsd 1 Thermal Shutdown ○ by Junction Temperature Controller 150 % 4 mS mS 1 2 S 1 % -0.04 0.04 %/ c -25 130 c 1 As long as faulty conditions have been removed , the adaptor will automatically power up as usual. ○ Environmental : Sym. Parameter Toper Operating Temperature Tstg Storage Temperature Hr Relative Humidity T e s t Conditions Min. Typ. Max. Unit No-Condensing MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 40 C to 50% load at 70 C 40 70 C -40 85 C 5 95 0 0.1M % Hrs HPU12A SERIES 12W Wall mount type medical power supplies For Home health care applications Safety Specifications: Parameter Sym. Vps Dielectric Withstanding Voltage for Primary to secondary CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Test Conditions Primary to secondary Vin=220VAC Vin=110VAC Min. Typ. Max. Unit 5600 VDC B B CLASS CLASS Output Voltage And Current Rating Chart ( Single Output ) : * * * * * Model Number Output Voltage Output Current Total Regulation Maximum Output Power HPU12A-102 5 ~ 6 VDC 2.00 ~ 1.66 A 5% 10W HPU12A-103 6 ~ 8 VDC 2.00 ~ 1.50 A 5% 12W HPU12A-104 8 ~ 11 VDC 1.50 ~ 1.09 A 5% 12W HPU12A-105 11 ~ 13 VDC 1.09 ~ 0.92 A 5% 12W HPU12A-106 13 ~ 16 VDC 0.92 ~ 0.75 A 5% 12W HPU12A-107 16 ~ 21 VDC 0.75 ~ 0.57 A 3% 12W HPU12A-108 21 ~ 27 VDC 0.57 ~ 0.45 A 3% 12W Mark “ * ” means approved by CEC level V. The total regulation on 102~104 required to use AWG#18/6FT output cable. The total regulation on 105~108 required to use AWG#20/6FT output cable. The regulation and efficiency will be changed by modified output cable. Mechanical Specifications:( USA Type) PO W E R Note: 1. Dimensions are shown in mm. 2. Weight: 130gs approx. 3. Optional output connector: See page Appendix.