HPU63A SERIES 63W Desk Top Switching Power Supplies For Health Care Applications. Description: The HPU63A series of AC/DC switching mode power supplies provide 63 Watts of continuous output power. All supplies are UL94V-1 min compliant. They are suited for use in Health care applications. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission Limits and are designed to comply with UL/c-UL(UL 60601-1:2ndEdition) ,TUV/T-mark (EN 606011:2ndEdition), and new CE requirements. All units are 100% burned in and tested. Features: Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz IEC-320-C14 Input Inlet Single Output Optional Output Connector (See appendix) Input Surge Current, Over Voltage And Over Load protection Output Voltage Protection(Crowbar Desing) Energy Star 2.0, Efficiency level V Class I 2 year warranty Safety Approvals : EN 60601-1 IEC 60601-1 Agree to apply for the PSE if order on hand Electrical Characteristics: Sym. Vin * Parameter Test Conditions Min. Typ. Max. Unit Safety Approvals Input Voltage Range 100 240 VAC Operate Voltage Range 90 264 VAC fin Po Vo Io Input Frequency Output Power Range Output Voltage Range Output Current Range 47 63 Hz W V A Iil Iih Input Current (Low Line) Input Current ( High Line) Io=Full load, Vin=115 VAC Io=Full load, Vin=230 VAC I rl Low Line Inrush Current I rh High Line Inrush Current Io=Full load, 25 C , Cool start, Vin= 115VAC Io=Full load, 25 C , Cool start, Vin= 230VAC Io=Full Load, Vin=230VAC Vin=90 to 264VAC 63 0 See rating chart See rating chart 1.62 0.72 A A 26 30 A 43 47 A 92 % % % Eff REG-i REG -o Efficiency OVP 112 Over Current Protection 110 150 Time of Transient Response Io=Full Load to Half Load, Vin=100VAC 4 Hold-Up Time Io=Full Load, Vin=110VAC 12 Io=Full Load, Vi n= 10 0V AC Start Up Time 0.3 1 2 Ripple & Noise (Peak to Peak) Full Load, Vin=100VAC 1 Safety Ground Leakage C urrent Io = Fu ll Load, Vin=240VAC 0.1 No-Load Power Consumption No load,Vin=240VAC 0.3 0.4 0.5 Temperature Coefficient -0.04 All output 0.04 OCP Ttr Thold Ts Vp-p Ilk Pno TC Line Regulation Load Regulation Over Voltage Protection 87 Io=Full Load Vin=230VAC 1 5 132 % % mS mS S % mA W %/ C * Note: The specifics for testing the energy efficiency of HPU63 Series are outlined in a separate document titled "Test Method for Calculating the Energy Efficiency of Single-Voltage External Ac-Dc and Ac-Ac PowerSupplies (August 11, 2004)," which is available on the ENERGY STAR Website. Environmental : Sym. Toper Parameter T e s t Conditions Operating Temperature Min. Typ. Max. Unit 40 70 C Storage Temperature -40 85 C Operating Humidity 0 95 % 0 75 Tstg Ho Hr Storage Humidity MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F Pd Derate linearly from 100% load at 40 C to 50% load at 70 C 0 0.1M % Hrs HPU63A SERIES 63W Desk Top Switching Power Supplies For Health Care Applications. Safety Specifications: Sym. Parameter Test Conditions Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage Vpg for Primary to Ground Ris Isolation Resistance CISPR EMI requirements for CISPR-11 FCC EMI requirements for FCC PART-18 Vps Min. Typ. Max. Unit Primary to secondary 5656 VDC Primary to ground 2828 VDC 50 B B M CLASS CLASS Test Voltage = 500VDC Vin=220VAC Vin=110VAC Output Voltage And Current Rating Chart (Single Output) : Model Number HPU63A-105 HPU63A-106 HPU63A-107 HPU63A-108 HPU63A-109 HPU63A-110 HPU63A-111 Output Voltage 12 15 18 24 30 36 48 VDC VDC VDC VDC VDC VDC VDC Output Current 5.25 4.20 3.50 2.62 2.10 1.75 1.31 A A A A A A A Total Regulation 5% 5% 5% 3% 3% 3% 3% M aximum Output Power 63W 63W 63W 63W 63W 63W 63W HPU63A-105~109 had been approved by PSE . HPU63A-105~107 are required to use AWG#16/2C/4FT output cable. HPU63A-108~110 are required to use AWG#18/2C/6FT output cable. The regulation and efficiency will be changed by modified output cable. Mechanical Specifications: Note: 1. Dimensions are shown in inches or mm. 2. Weight: 330-380gs approx. 3. Optional output connector: See page Appendix.