VOLGEN SPU50-2

SPU50 SERIES
60W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU50 series of AC/DC switching mode power supplies
provide 60 Watts of continuous output power. All supplies are
UL 94V-0 compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL, C-UL, TUV and CE requirements. All units are
100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 5VDC Thru 50VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Single Output
Splash proof
Class I Insulation
Two years warranty
Safety Approvals :
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
Vin
Input Voltage
90
264
VAC
Fin
Input Frequency
47
63
Hz
Wo
Output Power Range
0
60
W
Vo
Output Voltage Range
See rating chart
V
Io
Output Current Range
See rating chart
A
Iil
Input Current (Low Line)
Io=Full load, Vin=115VAC
1.6
A
Iih
Input Current (High Line)
Io=Full load, Vin=230 VAC
1.0
A
Irl
Low Line Inrush Current
12
15
A
Irh
High Line Inrush Current
26
30
A
Eff
Efficiency
Io=Full load, 25°c, Cool start,
Vin=115VAC
Io=Full load, 25°c, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
83
88
%
0.5
1
%
Vin=90 to 264VAC
REG-i Line Regulation
Io=Full Load
REG-o Load Regulation
Vin=230VAC
75
5
%
OVP
Over Voltage Protection
112
132
%
OCP
Over Current Protection
110
150
%
Ttr
Transient Response
4
mS
Thold Hold-Up Time
3
Io=Full Load to Half Load,Vin=100VAC
Io=Full Load, Vin=100VAC
16
0.3
Ts
Start Up Time
Io=Full Load, Vin=100VAC
Vrn
Ripple & Noise (Pe ak to Peak)
Full Load, Vin=90VAC
Ilk
Safety Ground Leakage Current
Io=Full Load, Vin=240VAC
Tc
Temperature Coefficient
All output
mS
1
2
S
0.5
1
%
0.5
0.75
mA
0.04
%/°c
Max.
Unit
0
70
°c
-40
85
°c
5
95
%
-0.04
Environmental :
Sym.
Parameter
Toper
Operating Temperature
Tstg
Storage Temperature
Test Conditions
Hr
Relative Humidity
Pd
Derate linearly from 100% load at 40°c to 50% load at 70°c
Min.
Typ.
SPU50 SERIES
60W Desk Top Switching Power Supplies For I.T.E.
Safety Specifications:
Sym.
Vps
Vpg
Ri
Parameter
Dielectric Withstanding Voltage
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to ground
Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC
EMI requirements for FCC PART-15
Test Conditions
Min. Typ. Max.
Unit
Primary to secondary
4242
VDC
Primary to ground
2121
VDC
Test Voltage = 500VDC
50
MW
Vin=220VAC
B
CLASS
Vin=110VAC
B
CLASS
Output Voltage And Current Rating Chart ( Single Output ) :
Model Number
Output Voltage
Output Current
Total Regulation
Maximum
Output Power
SPU50-1
05 ~ 06 VDC
10.0 ~ 8.30 A
5%
50W
SPU50-1-1
06 ~ 09 VDC
9.10 ~ 6.11 A
5%
55W
SPU50-2
09 ~ 11 VDC
6.50 ~ 5.31 A
5%
58.5W
SPU50-3
11 ~ 13 VDC
5.45 ~ 4.61 A
5%
60W
SPU50-4
13 ~ 16 VDC
4.61 ~ 3.75 A
5%
60W
SPU50-5
16 ~ 21 VDC
3.75 ~ 2.86 A
5%
60W
SPU50-6
21 ~ 27 VDC
2.86 ~ 2.22 A
5%
60W
SPU50-7
27 ~ 33 VDC
2.22 ~ 1.82 A
5%
60W
SPU50-8
33 ~ 40 VDC
1.82 ~ 1.50 A
5%
60W
SPU50-9
40 ~ 50 VDC
1.50 ~ 1.20 A
5%
60W
Mechanical Specifications :
Note:
1. Dimensions are shown in mm.
2. Weight: 520gs approx.
3. Optional output connector:
See page Appendix.