DC-AC INVERTER UNIT PS-DA0602-01(S) (30 W SIXFOLD OUTPUTS) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC to AC Inverter is developed for sextuple lamps. APPLICABLE LCD: 15 to 30 inches sextuple lamp type Lamp Voltage 769 Vrms Lamp Current 6 x 6.5 mArms Lamp Start Up Voltage 1.650 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Open Lamp Detection RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH Pin 1 0°C ~ +50°C -20°C ~ +85°C 95 %RH max 170 x 60 x 9.5 mm Pin 1 Pin 1 Pin 1 Pin 1 Pin 1 Pin 1 Unit : mm Weight :64 (g) typ. Pin 1 Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 Part Description PCB Connector CN1 Qty. 1 1 Material UL94V-0 (FR-4 or CEM-3) S8B-PH-SM3-TB Note t=1m m JST or equal 3 Connector CN2 ~ CN7 6 SM02B-BHSS-1-TB JST or equal Input side CN1: Output side CN2 ~ CN7 Pin No. Symbols Ratings Vin 12 Vdc CN 1-1+2+3 GND CN 1-4+5+6 Vbr 0 ~ 3.3 Vdc CN 1-7 Vrm t 0 ~ 1.5 = OFF / 2.5 ~ 5.5 = ON CN 1-8 Pin No. CN 2-1 Symbols Vhigh Ratings 769 Vrm s (6.5 m Arm s ) CN 2-2 Vlow (GND) Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.4.5, 28th April 2008 DC-AC INVERTER UNIT PS-DA0602-01(S) (30 W SIXFOLD OUTPUTS) (PRELIMINARY INFORMATION) ELECTRICAL CHARACTERISTICS : Parameters Symbols Iout 12±1.2 5±0.25 0 ~ +50 Iout Iin F Vopen 12±0.6 12±1.2 12±1.2 11.4 5±0.25 5±0.25 5±0.25 5±0.25 Ts d 12±1.2 5±0.25 0 ~ +50 Output Current Output Current Input Current Frequency Open Circuit Voltage No load Shutdow n Note 1: Conditions Vrmt Vin (V) Tu (°C) (V) 0 0 0 0 Specification ~ +50 ~ +50 ~ +50 ~ +50 Unit Note 7.0 m Arm s V in = 12 V d c V d im =0 V Dut y = 100 % 35 2.4 50 1.650 3.4 60 1.900 % Adc kHz Vrm s V dim = 5.0 V 1.0 - s ec wit hout load Min. Typ. Max. - 6.5 40 1.500 - Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Before apply any control signal into inverter, please provide Vcc first. Please follow the reversed sequence during power off. Power off control signal first, then power off Vcc. Note 2: TEST CIRCUIT : F A Vin 12 V Iin 1000:1 PROBE F Vopen CN2-1 CN1-1 CN1-2 CN1-3 V SW3 SW4 A ~ Iout 1 A ~ CL2 Iout 2 A ~ CL3 Iout 3 A ~ CL4 Iout 4 A ~ CL5 Iout 5 A ~ CL6 Iout 6 Operation of unit a Operation b Non operation CL1 RL1 CN2-2 SW 1 V ~ SW5 CN3-1 RL2 T1 CN3-2 SW6 SW7 CN1-4 CN1-5 CN1-6 CN4-1 RL3 SW8 CN4-2 SW9 CN5-1 RL4 CN1-7 CN5-2 SW10 SW11 CN6-1 Vbr 0 ~ 3.3 Vdc RL5 Vrmt 0.4 / 5 Vdc a V b SW1 CN6-2 SW12 SW13 CN7-1 CN1-8 RL6 CN7-2 SW14 Dimming Characteristic: Iout (in %) 100 80 60 40 20 0 0 1 2 3 3,3 Vbr (VDC) Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.4.5, 28th April 2008