RHOMBUS-IND T

10BASE-T INTERFACE TRANSFORMER
Reinforced Insulation Per EN 41003/EN 60950
Turns Ratio ( + 5% )
1CT:1CT
Parameter
Min.
Open Circuit Inductance
200
Max.
Units
Transformer can be used for Transmit
or Receive side.
µH
Leakage Inductance
0.8
µH
Interwinding Capacitance (CW/W)
15
pF
Primary DC Resistance
0.4
ohms
Secondary DC Resistance
0.5
ohms
4000
Isolation (HI-POT)
Meets IEE 802.3 and ANSI X3.263
Standards.
Flammability: Materials used in the
production of these units meet
requirements of UL94-VO and IEC
695-2-2 needle flame test.
0.5mm minimum insulation thickness
between primary and secondary.
V RMS
Parts shipped in anti-static tubes.
31 pieces per tube
OPERATING TEMPERATURE RANGE:
-400C TO +850C
Physical Dimensions
inches (mm)
.560
(14.22)
MAX.
Schematic Diagram
.560
(14.22)
MAX.
PRI
.400
(10.16)
MAX. .010
(0.25)
TYP.
.035
(0.89)
TYP.
.020 .100
(0.51) (2.54)
TYP. TYP.
10
.110
(2.79)
TYP. .740 (18.80)
.710 (18.03)
SEC
1
10
3
8
5
6
6
PRELIMINARY!
RHOMBUS P/N: T-1482G
1
5
Rhombus
Industries Inc.
Transformers & Magnetic Products
CUST P/N:
DATE: 01/08/02
www.rhombus-ind.com
NAME:
SHEET: 1 OF 1
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971