SDA116 Series Solid State Devices, Inc. 14830 Valley View Blvd * La Mirada, Ca 90638 Phone: (562) 404-7855 * Fax: (562) 404-1773 [email protected] * www.ssdi-power.com DESIGNER’S DATA SHEET 25A / 1000V THREE PHASE BRIDGE RECTIFIER ASSEMBLY ULTRA FAST – 70 ns Part Number / Ordering Information 1/ SDA116 __ __ __ ¦ + Lead Bend 3/ __ = Straight Leads ¦ ¦ ¦ UB = Up Bend ¦ ¦ DB = Down Bend ¦ ¦ ¦ + Terminals 2/ 3/ L = Copper Leads ¦ _ = Turret Terminals ¦ + Voltage J = 600 V K = 800 V M = 1000 V Features: • • • • • • • Higher Blocking Voltage Available. Contact Factory. Average Output Current 25 Amps Low Reverse Leakage Current Constructed with Void-free, Hermetically Sealed Discretes Aluminum Case for Maximum Thermal Conductivity Small Package Size (1.500 x 0.875 x 0.310”) TX and TXV & S Level Screening Available • Standard, Fast, & Hyper Fast Versions Available. Contact Factory. Maximum Ratings Peak Repetitive and Peak Surge Reverse Voltage Average Rectified Forward Current 4/ (Resistive Load, 60 Hz Sine Wave) Symbol Value Units SDA116J SDA116K SDA116M VRRM VRSM VR 600 800 1000 Volts TC = 55°C Io 25 Amps IFSM 125 Amps Top & Tstg -55 to +150 ºC RθJC 2.5 ºC/W Peak Surge Current (8.3 ms Pulse, Half Sine Wave, TA = 25 °C, per leg) Operating & Storage Temperature Maximum Thermal Resistance, Junction to Case 1 SDA116 ( L ) SDA116 (_) Lead Dia = .050” Lead Length = 0.5” min NOTE: All specifications are subject to change without notification. SCD's for these devices should be reviewed by SSDI prior to release. DATA SHEET #: RA0046A DOC SDA116 Series Solid State Devices, Inc. 14830 Valley View Blvd * La Mirada, Ca 90638 Phone: (562) 404-7855 * Fax: (562) 404-1773 [email protected] * www.ssdi-power.com Electrical Characteristic 5/ Symbol Min Typ Max Units VF1 –– –– –– –– –– –– 1.40 1.75 1.95 Volts Reverse Leakage Current (Rated VR, TA = 25ºC, pulsed) IR1 –– –– 25 µA Reverse Leakage Current (Rated VR, TA = 100ºC, pulsed) IR2 –– –– 500 µA Reverse Recovery Time (IF = 500 mA, IR = 1 A, IRR = 250 mA TA = 25ºC trr –– –– 70 ns Instantaneous Forward Voltage Drop (TA = 25°C, pulsed) (TA = 25°C, pulsed) (TA = -55°C, pulsed) IF = 3A IF = 9A IF = 9A NOTES: 1/ 2/ 3/ 4/ 5/ For Ordering Information, Price, and Availability Contact Factory. For Package Outlines Contact Factory. Up and Down Bend Configurations are Available for ‘__’ ( Leaded ) Packages Only. Derate Linearly at 0.26 A/ºC for TC > 55ºC. Unless Otherwise Specified, All Electrical Characteristics @25ºC. Mounting Diagram: 2/ Thickness = 0.340” min