2000 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER Environmental Measuring Instrument Easy clamp current recording and convenient, low-cost voltage recording Extended recording of AC current and voltage transients ● D a t a b a c k u p w h e n b a t t e r i e s a re e x h a u s t e d o r re p l a c e d ● I n s t a n t a n e o u s / a v e r a g e re c o rd i n g ( a v e r a g e o v e r re c o rd i n g i n t e r v a l ) ● G r a p h i c d i s p l a y o f re c o rd e d d a t a t h ro u g h a c o m p u t e r ● Equipped with alarm output (3636-20) http://www.hioki.co.jp/ ISO14001 JQA-E-90091 HIOKI company overview, new products, environmental considerations and other information are available on our website. 3636-20 CLAMP LOGGER 500A AC 3637-20 AC VOLTAGE LOGGER 600V AC Analyze and Process Data on a Personal Computer The 3911-20 Communication Base is used to transfer data to a personal computer. The 3911-20 accommodates up to 16,000 points of 16-channel data or 32,000 points of 8-channel data. It captures data from multiple loggers, then transfers data to the computer where it can be analyzed and managed. 3911-20 LOGGER Functions Infrared optical communication Approximately 500 data points/second RS-232C Approximately 1000 data points/second (Logger and 3911 must be in direct contact for communication.) Communication software included with the 3911-20 Settings for communication software Current time, recording interval, recording start, recording method, comment, recording mode (3636-20/3637-20). Alarm and channel selection (3636-20 only) Compatible OS: Windows 95/98/NT4.0 ● Graph display ● Measurement data tabulation ● Printing (data, graphs) ● Scaling ● File saving (in proprietary format or text format) Windows is a registered trademark of Microsoft Corporation ■ 3636-20/3637-20 Specifications ■ 3636-20/3637-20 Common Specifications Display * 50A or 500A range when using the 9650, and 500A range when using the 9651 : Measured value, recording status, recording interval, battery condition, unit, recording in progress, preset active, average value recording, maximum value, minimum value, alarm (3636-20 only) : Started manually or at preset time Recording start : Manual stop or until memory is full Recording finish : 1/2/5/10/15/20/30 seconds, 1/2/5/10/15/20/30/60 minutes Recording interval : One-time: Recording stops when memory becomes full. Recording methods Endless: Oldest data is overwritten when memory becomes full. : Instantaneous value recording, average value recording Recording modes (average over the recording interval) : Infrared optical communication (requires the 3911) Interface : LR03 (AAA) × 4 alkaline batteries Power supply : 0.1 VA Maximum rated power : About 1 year (with a recording interval of 1 minute and Continuous use time instantaneous value recording) About 1 month (with average value recording) : Approx. 57.5(W) × 86.5(H) × 30.0(D) mm, approx. 130 g Dimensions/mass : Indoors at an altitude of no more than 2000 m Operating environment : 0 to 50˚C, less than 80% rh (no condensation) Ambient use conditions Ambient storage conditions : -10 to 60˚C, less than 80% rh (no condensation) : EMC EN61326-1 : 1997+A1 : 1998 Applicable standards Safety EN61010-1 : 1993+A2 : 1995 Overvoltage category I (anticipated overvoltage: 330V), pollution index 2 (3636-20) Overvoltage category III (anticipated overvoltage: 6000V), pollution index 2 (3637-20) ■ 9650/9651 Specifications ■ 3911-20 COMMUNICATION BASE Specifications 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER Input AC current AC voltage Number of input channels 2 channels 1 channel Data recording capacity 32,000 data points (1 ch) 16,000 data points (2 ch) 32,000 data points Measurement range 0.00 to 500.0 Arms.sin (50A/500A, 2 ranges) 0.0 to 600.0 Vrms.sin ±1% rdg. ±5 dgt. (logger only) ±2.5% rdg. ±8 dgt. (logger + sensor)* ±1% rdg. ±5 dgt. Accuracy (50/60 Hz, 23±5˚C) Alarm output ON when set upper/lower limits exceeded None Measurement system True RMS calculation True RMS calculation LR03 (AAA) alkaline batteries × 4, 9632 connection cord (for alarm output) LR03 (AAA) alkaline batteries ×4, 9639 connection cord (for input) 3911-20 Communication Base, 9650/9651 Clamp-on Sensor 3911-20 Communication Base Accessories Options × Rated primary current Rated secondary current 9650 CLAMP ON SENSOR 9651 CLAMP ON SENSOR AC100A AC500A AC100mA AC500mA ±1.5% rdg. ±0.03%f.s. (where f.s. is rated primary current) ±1.5% rdg. ±0.03%f.s. (where f.s. is rated primary current) Frequency response 40 Hz to 1 kHz, within ±8% 40 Hz to 1 kHz, within ±3% Maximum rated input 130A continuous (45 to 66 Hz) 600A continuous (45 to 66 Hz) AC 300Vrms or less (insulated conductor) AC 600Vrms or less (insulated conductor) φ 15 mm or less φ 46 mm or less Approx. 3 m Approx. 3 m Accuracy (50/60 Hz, 23±5˚C) Circuit voltage Measurable conductor diameter Cord length Dimensions/ mass Approx. 46(W) × 135(H) × 21(D) mm, Approx. 77(W) × 151(H) × 42(D) mm, approx. 200 g approx. 340 g : Max 16,000 data points × 16 ch / 32,000 data points × 8 ch : Logger ⇔ 3911-20: by infrared optical communication (with units in close contact) 3911-20 ¤ PC: by RS-232C connection : LR03 (AAA) × 4 alkaline batteries Power supply : 0.2 VA Maximum rated power : Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g Dimensions/mass : 0 to 40.0˚C, max 80% rh (no condensation) Ambient use conditions Ambient storage conditions : -10.0 to 50.0˚C, max 80% rh (no condensation) : PC communication software Accessories Recording capacity Communication type 9650 9651 9639 9632 CLAMP ON SENSOR CLAMP ON SENSOR CONNECTION CABLE CONNECTION CABLE ■ Options 3636-20 CLAMP LOGGER 3637-20 AC VOLTAGE LOGGER The 3636-20 CLAMP LOGGER cannot be used for measurement by itself. A clamp-on sensor (sold separately) is required. 3911-20 COMMUNICATION BASE 9650 CLAMP ON SENSOR (100A) 9651 CLAMP ON SENSOR (500A) 9632 CONNECTION CABLE (included with the 3636-20, 1 m) 9639 CONNECTION CABLE (included with the 3637-20, 3 m) 9637 RS-232C CABLE (9 pin-to-9 pin, null modem, 1.8 m) 9638 RS-232C CABLE (9 pin-to-25 pin, null modem, 1.8 m) DISTRIBUTED BY HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL+81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 All information correct as of Apr. 7, 2000. All specifications are subject to change without notice. ■Inter net HIOKI website h t t p : / / w w w . h i o k i . c o . j p / F3636E1-04B-05P Printed in Japan