302810297_Hioki Voltage & Current Loggers

2000
3636-20 CLAMP LOGGER
3637-20 AC VOLTAGE LOGGER
Environmental Measuring
Instrument
Easy clamp current recording and
convenient, low-cost voltage recording
Extended recording of AC current and
voltage transients
● D a t a b a c k u p w h e n b a t t e r i e s a re e x h a u s t e d o r re p l a c e d
● I n s t a n t a n e o u s / a v e r a g e re c o rd i n g
( a v e r a g e o v e r re c o rd i n g i n t e r v a l )
● G r a p h i c d i s p l a y o f re c o rd e d d a t a t h ro u g h a c o m p u t e r
● Equipped with alarm output (3636-20)
http://www.hioki.co.jp/
ISO14001
JQA-E-90091
HIOKI company overview, new products, environmental considerations and
other information are available on our website.
3636-20
CLAMP LOGGER
500A AC
3637-20
AC VOLTAGE LOGGER
600V AC
Analyze and Process Data on a
Personal Computer
The 3911-20 Communication Base is used to transfer data to a personal
computer. The 3911-20 accommodates up to 16,000 points of 16-channel data
or 32,000 points of 8-channel data. It captures data from multiple loggers, then
transfers data to the computer where it can be analyzed and managed.
3911-20
LOGGER
Functions
Infrared optical communication
Approximately 500 data points/second
RS-232C
Approximately 1000 data points/second
(Logger and 3911 must be in direct contact for
communication.)
Communication software included
with the 3911-20
Settings for communication software
Current time, recording interval, recording start,
recording method, comment, recording mode (3636-20/3637-20).
Alarm and channel selection (3636-20 only)
Compatible OS: Windows 95/98/NT4.0
● Graph display
● Measurement data tabulation
● Printing (data, graphs)
● Scaling
● File saving (in proprietary
format or text format)
Windows is a registered trademark of Microsoft Corporation
■ 3636-20/3637-20 Specifications
■ 3636-20/3637-20 Common Specifications
Display
* 50A or 500A range when using the 9650, and 500A range when using the 9651
: Measured value, recording status, recording interval, battery
condition, unit, recording in progress, preset active, average
value recording, maximum value, minimum value,
alarm (3636-20 only)
: Started manually or at preset time
Recording start
: Manual stop or until memory is full
Recording finish
: 1/2/5/10/15/20/30 seconds, 1/2/5/10/15/20/30/60 minutes
Recording interval
: One-time: Recording stops when memory becomes full.
Recording methods
Endless: Oldest data is overwritten when memory becomes full.
: Instantaneous value recording, average value recording
Recording modes
(average over the recording interval)
: Infrared optical communication (requires the 3911)
Interface
: LR03 (AAA) × 4 alkaline batteries
Power supply
: 0.1 VA
Maximum rated power
: About 1 year (with a recording interval of 1 minute and
Continuous use time
instantaneous value recording)
About 1 month (with average value recording)
: Approx. 57.5(W) × 86.5(H) × 30.0(D) mm, approx. 130 g
Dimensions/mass
: Indoors at an altitude of no more than 2000 m
Operating environment
: 0 to 50˚C, less than 80% rh (no condensation)
Ambient use conditions
Ambient storage conditions : -10 to 60˚C, less than 80% rh (no condensation)
: EMC EN61326-1 : 1997+A1 : 1998
Applicable standards
Safety EN61010-1 : 1993+A2 : 1995
Overvoltage category I
(anticipated overvoltage: 330V), pollution index 2 (3636-20)
Overvoltage category III
(anticipated overvoltage: 6000V), pollution index 2 (3637-20)
■ 9650/9651 Specifications
■ 3911-20 COMMUNICATION BASE Specifications
3636-20 CLAMP LOGGER
3637-20 AC VOLTAGE LOGGER
Input
AC current
AC voltage
Number of
input channels
2 channels
1 channel
Data recording
capacity
32,000 data points (1 ch)
16,000 data points (2 ch)
32,000 data points
Measurement
range
0.00 to 500.0 Arms.sin
(50A/500A, 2 ranges)
0.0 to 600.0 Vrms.sin
±1% rdg. ±5 dgt. (logger only)
±2.5% rdg. ±8 dgt. (logger + sensor)*
±1% rdg. ±5 dgt.
Accuracy
(50/60 Hz, 23±5˚C)
Alarm output
ON when set upper/lower limits exceeded
None
Measurement
system
True RMS calculation
True RMS calculation
LR03 (AAA) alkaline batteries × 4,
9632 connection cord (for alarm output)
LR03 (AAA) alkaline batteries ×4,
9639 connection cord (for input)
3911-20 Communication Base,
9650/9651 Clamp-on Sensor
3911-20 Communication Base
Accessories
Options
×
Rated primary
current
Rated secondary
current
9650 CLAMP ON SENSOR
9651 CLAMP ON SENSOR
AC100A
AC500A
AC100mA
AC500mA
±1.5% rdg. ±0.03%f.s.
(where f.s. is rated primary current)
±1.5% rdg. ±0.03%f.s.
(where f.s. is rated primary current)
Frequency
response
40 Hz to 1 kHz, within ±8%
40 Hz to 1 kHz, within ±3%
Maximum
rated input
130A continuous (45 to 66 Hz)
600A continuous (45 to 66 Hz)
AC 300Vrms or less
(insulated conductor)
AC 600Vrms or less
(insulated conductor)
φ 15 mm or less
φ 46 mm or less
Approx. 3 m
Approx. 3 m
Accuracy
(50/60 Hz, 23±5˚C)
Circuit voltage
Measurable
conductor
diameter
Cord length
Dimensions/
mass
Approx. 46(W) × 135(H) × 21(D) mm, Approx. 77(W) × 151(H) × 42(D) mm,
approx. 200 g
approx. 340 g
: Max 16,000 data points × 16 ch / 32,000 data points × 8 ch
: Logger ⇔ 3911-20: by infrared optical communication (with
units in close contact)
3911-20 ¤ PC: by RS-232C connection
: LR03 (AAA) × 4 alkaline batteries
Power supply
:
0.2 VA
Maximum rated power
: Approx. 69(W) × 92(H) × 36(D) mm, approx. 150 g
Dimensions/mass
:
0 to 40.0˚C, max 80% rh (no condensation)
Ambient use conditions
Ambient storage conditions : -10.0 to 50.0˚C, max 80% rh (no condensation)
:
PC communication software
Accessories
Recording capacity
Communication type
9650
9651
9639
9632
CLAMP ON SENSOR
CLAMP ON SENSOR
CONNECTION CABLE
CONNECTION CABLE
■ Options
3636-20 CLAMP LOGGER
3637-20 AC VOLTAGE LOGGER
The 3636-20 CLAMP LOGGER cannot be used for measurement
by itself. A clamp-on sensor (sold separately) is required.
3911-20 COMMUNICATION BASE
9650 CLAMP ON SENSOR (100A)
9651 CLAMP ON SENSOR (500A)
9632 CONNECTION CABLE (included with the 3636-20, 1 m)
9639 CONNECTION CABLE (included with the 3637-20, 3 m)
9637 RS-232C CABLE (9 pin-to-9 pin, null modem, 1.8 m)
9638 RS-232C CABLE (9 pin-to-25 pin, null modem, 1.8 m)
DISTRIBUTED BY
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL+81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@ hioki.co.jp
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
All information correct as of Apr. 7, 2000. All specifications are subject to change without notice.
■Inter net HIOKI website h t t p : / / w w w . h i o k i . c o . j p /
F3636E1-04B-05P