AXTAL AXLE184

Issue: 01
Specification
AXLE184
Oscillator type : TCXO in DIL14 compatible package
Parameter
Frequency range
Frequency stability
vs. temperature
vs. supply voltage variation
vs. load change
long term (aging) per year
Frequency adjustment range
Mechanical (internal trimmer)
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Amplitude
Supply voltage VS
Current consumption (Note 3)
Storage temperature range
Enclosure (see drawing)
Marking
min.
typ.
6
1
max.
Unit
Condition
190
800
MHz
MHz
ppm
ppm
ppm
ppm
ppm
(Clipped) Sinewave
HCMOS, PECL, LVDS
See tables 1 & 2
ppm
ppm
V
V
Option 1 = blank
Option 1 = “V”
Option 2 = “3”
Option 2 = “5”
± 0.5 ppm to ± 5 ppm
± 0.1
± 0.3
± 0.2
±1
±3
±5
0.15
0.5
1.65
2.5
positive
100
Date:2008-05-05
3.15
4.5
± 10 %
@+40°C
kΩ
Sine wave
Clipped Sine wave
HCMOS
PECL
LVDS
50 Ω
10 kΩ || 10 pF
15 pF
50 Ω + bias
0
dBm
+10
dBm
0.8
V p-p
1.0
V p-p
According to relevant Logic Standard
3.15
3.3
3.45
V
4.75
5.0
5.25
V
12 ~ 30
mA
2 ~ 30
mA
15 ~ 50
mA
25 ~ 100
mA
-45
+90
°C
18.6 x 12.0 x 7.3 max.
mm
AXLE184
Freq
wwAXPyy
Tape & reel
Lead(Pb) -free
Option 3 = “S”
Option 3 = “C”
Option 3 = “H”
Option 3 = “P”
Option 3 = “L”
Option 3 = “S”
Option 3 = “C”
Option 3 = “H”
Option 3 = “P” or “L”
Option 3 = “S” / 3.3 V
Option 3 = “S” / 5.0 V
Option 3 = “C” / 3.3 V
Option 3 = “C” / 5.0 V
Option 3 = “H”, “P”,“L”
Option 2 = “3”
Option 2 = “5”
Option 3 = “S”
Option 3 = “C”
Option 3 = “H”
Option 3 = “P” or “L”
Pin compatible to CO 02
Specification
Frequency
ww=week, yy=year
IEC 60286-3
Packing
Construction
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. All combinations of options might not be available. Please consult factory
3. Depending on frequency and supply voltage
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXLE184
page 1(2)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Frequency Stability over Temperature
Table 1
Code4 Stability
05
± 0.5
10
± 1.0
15
± 1.5
20
± 2.0
25
± 2.5
30
± 3.0
35
± 3.5
50
± 5.0
Table 2
Lower
Temperature
Code5 Temp/°C
0
0
1
-10
2
-20
3
-30
4
-40
Upper Temperature
Code5
A
B
C
D
E
F
Temp/°C
+50
+60
+70
+75
+80
+85
Ordering Code:
Part number
AXLE184
Option 1
Option 2
Option 3
Option 4
Option 5
EFC
Supply Voltage
Output
Stability
Temp. range
_ or “V”
5 or 3
S, C, H, P, L
See tables 1 & 2
Example: AXLE184V-5-S-10-3D
Enclosure drawing
Pin connections (No EFC)
Pin # Symbol
Function
1
N.C. or
No Connection or
ComplOUT Complementary Output
(PECL and LVDS)
2
GND
Ground
3
RF OUT RF Output
4
Vs
Supply Voltage
Pin connections (With EFC)
Pin # Symbol
1
VC
2
GND
3
RF OUT
4
VS
5
ComplOUT
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXLE184
page 2(2)
Function
Voltage Control (EFC)
Ground
RF Output
Supply Voltage
Complementary Output
(PECL and LVDS)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]