Issue: 01 Specification AXLE184 Oscillator type : TCXO in DIL14 compatible package Parameter Frequency range Frequency stability vs. temperature vs. supply voltage variation vs. load change long term (aging) per year Frequency adjustment range Mechanical (internal trimmer) Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load Amplitude Supply voltage VS Current consumption (Note 3) Storage temperature range Enclosure (see drawing) Marking min. typ. 6 1 max. Unit Condition 190 800 MHz MHz ppm ppm ppm ppm ppm (Clipped) Sinewave HCMOS, PECL, LVDS See tables 1 & 2 ppm ppm V V Option 1 = blank Option 1 = “V” Option 2 = “3” Option 2 = “5” ± 0.5 ppm to ± 5 ppm ± 0.1 ± 0.3 ± 0.2 ±1 ±3 ±5 0.15 0.5 1.65 2.5 positive 100 Date:2008-05-05 3.15 4.5 ± 10 % @+40°C kΩ Sine wave Clipped Sine wave HCMOS PECL LVDS 50 Ω 10 kΩ || 10 pF 15 pF 50 Ω + bias 0 dBm +10 dBm 0.8 V p-p 1.0 V p-p According to relevant Logic Standard 3.15 3.3 3.45 V 4.75 5.0 5.25 V 12 ~ 30 mA 2 ~ 30 mA 15 ~ 50 mA 25 ~ 100 mA -45 +90 °C 18.6 x 12.0 x 7.3 max. mm AXLE184 Freq wwAXPyy Tape & reel Lead(Pb) -free Option 3 = “S” Option 3 = “C” Option 3 = “H” Option 3 = “P” Option 3 = “L” Option 3 = “S” Option 3 = “C” Option 3 = “H” Option 3 = “P” or “L” Option 3 = “S” / 3.3 V Option 3 = “S” / 5.0 V Option 3 = “C” / 3.3 V Option 3 = “C” / 5.0 V Option 3 = “H”, “P”,“L” Option 2 = “3” Option 2 = “5” Option 3 = “S” Option 3 = “C” Option 3 = “H” Option 3 = “P” or “L” Pin compatible to CO 02 Specification Frequency ww=week, yy=year IEC 60286-3 Packing Construction Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. All combinations of options might not be available. Please consult factory 3. Depending on frequency and supply voltage GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXLE184 page 1(2) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Frequency Stability over Temperature Table 1 Code4 Stability 05 ± 0.5 10 ± 1.0 15 ± 1.5 20 ± 2.0 25 ± 2.5 30 ± 3.0 35 ± 3.5 50 ± 5.0 Table 2 Lower Temperature Code5 Temp/°C 0 0 1 -10 2 -20 3 -30 4 -40 Upper Temperature Code5 A B C D E F Temp/°C +50 +60 +70 +75 +80 +85 Ordering Code: Part number AXLE184 Option 1 Option 2 Option 3 Option 4 Option 5 EFC Supply Voltage Output Stability Temp. range _ or “V” 5 or 3 S, C, H, P, L See tables 1 & 2 Example: AXLE184V-5-S-10-3D Enclosure drawing Pin connections (No EFC) Pin # Symbol Function 1 N.C. or No Connection or ComplOUT Complementary Output (PECL and LVDS) 2 GND Ground 3 RF OUT RF Output 4 Vs Supply Voltage Pin connections (With EFC) Pin # Symbol 1 VC 2 GND 3 RF OUT 4 VS 5 ComplOUT GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXLE184 page 2(2) Function Voltage Control (EFC) Ground RF Output Supply Voltage Complementary Output (PECL and LVDS) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]