Issue: 01 Specification AXIS207 Oscillator type : VCXO in DIL14 package Parameter Frequency range Frequency stability vs. temperature vs. supply voltage variation vs. load change long term (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC min. 6 1 Load Amplitude Supply voltage VS Current consumption (Note 3) Storage temperature range Enclosure (see drawing) L x W x H Marking max. Unit Condition 190 800 Sinewave HCMOS, PECL, LVDS ±3 MHz MHz ppm ppm ppm ppm ppm 3.15 5 ppm ppm ppm V V Option 5 = “5” Option 5 = “10” Option 5 = “15” Option 1 = “3” Option 1 = “5” Option 6 = blank Option 6 = “N” (Note 4) ± 10 ppm to ± 100 ppm ± 50 ± 100 ± 150 0.15 0 EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform typ. 1.65 2.5 Positive negative 100 Date:2008-05-07 See tables 1 & 2 ± 10 % @+40°C kΩ Sine wave HCMOS PECL LVDS 50 Ω 15 pF 50 Ω + bias 0 dBm +10 dBm According to relevant Logic Standard 3.15 3.3 3.45 V 4.75 5.0 5.25 V 15 ~ 70 mA 15 ~ 100 mA 25 ~ 100 mA -45 +90 °C 20.7 x 13,1 x 5.1 max. mm or 20.7 x 13,1 x 7.5 max. AXIS207 Freq wwAXPyy Tape & reel Lead(Pb) -free Option 2 = “S” Option 2 = “H” Option 2 = “P” Option 2 = “L” Option 2 = “S” Option 2 = “H” Option 2 = “P” or “L” Option 2 = “S” / 3.3 V Option 2 = “S” / 5.0 V Option 2 = “H”, “P”,“L” Option 1 = “3” Option 1 = “5” Option 2 = “S” Option 2 = “H” Option 2 = “P” or “L” IEC60679-3 CO 02 Specification Frequency ww=week, yy=year IEC 60286-3 Packing Construction Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. All combinations of options might not be available. Please consult factory 3. Depending on frequency and supply voltage 4. Negative slope only available for HCMOS Output version (Option 2 = “H”) GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIS207 page 1(2) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Frequency Stability over Temperature Table 1 Code4 Stability 10 ± 10 15 ± 15 20 ± 20 30 ± 30 50 ± 50 100 ± 100 Table 2 Lower Temperature Code5 Temp/°C 0 0 1 -10 2 -20 3 -30 4 -40 Upper Temperature Code5 A B C D E F Temp/°C +50 +60 +70 +75 +80 +85 Ordering Code: Part number Option 1 Option 2 Option 3 Option 4 Supply Voltage Output Stability Temp. range AXIS207 5 or 3 S, H, P, L See tables 1 & 2 Option 5 Option 6 Pulling range Pulling slope 5, 10, 15 _ or “N” All combinations of options might not be available. Please consult factory Example: AXIS207-5-S-10-2C-5 Enclosure drawings Pin connections Sine wave and HCMOS Pin # Symbol 1 VC 2 GND 3 RF OUT 4 VS Function Voltage Control (EFC) Ground RF Output Supply Voltage PECL and LVDS Pin # Symbol 1 VC 2 GND 3 RF OUT 4 VS 5 CompOut GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXIS207 page 2(2) Function Voltage Control (EFC) Ground RF Output Supply Voltage Complementary Output ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]