AZETTLER XMC0

XMC0 Series
Definite Purpose Contactors
Description
American Zettler’s XMC0 series of Definite Purpose Contactors are
electromechanical switching devices designed ideally for the HVAC
industry. The most common applications of our contactors are found in
refrigeration, air conditioning and heating. Other applications include
elevators, food service equipment, cranes, hoists, welding machines,
power supplies, vending machines, lighting, pumps and compressors.
XMC0 contactors are built to the ARI 780/790 standard in our ISO 9001
manufacturing facility for high performance and great reliability. XMC0 is
available in various pole configurations and load ratings up to 90 amps.
Features
• A variety of termination options for specific application requirements
• Universal mounting plate: Easy replacement of competitor's contactors
• Heavy-duty contacts ensure long electrical life
• EE lamination (magnetic assembly) provides optimum performance
while reducing power consumption
• Performance unaffected by position mounting
• Dust-free internal construction
• UL, CUR file no. E222994
11/7/07W
XMC0 Series
PART NUMBERING SYSTEM
XMC0
-
3 • E
50
B
B
C - H - XXXX
Full Load Amps
Number of Poles
Coil Voltage
Mounting Plate
Cover
Terminal
Contact Material
Custom Special Code
Full Load Amp
Mounting Plate
25
25 FLA
32
32 FLA
40
40 FLA
50
*50 FLA
63
75
90
*63 FLA
75 FLA
90 FLA
A
Plastic Base
B
Metal Plate
Metal Plate with
C
DIN rail mounting*
* Available for 50 &63 Amp versions only
* CUR approval pending
Number of Poles
Cover
1
1-pole + 1 shunt - Compact
2
2-pole - Compact
A
Long cover
7
1-pole - Compact
B
Short cover
3
3-pole* - Standard
3A
2-pole - Standard
* 3P is only option for 50/63/75/90 Amp models
Coil Voltage
50Hz
Terminal with Quick Connects
A
Screw
60Hz
B
Sems clamp
D
12V
12V
C
Slotted & Hex head washer
E
24V
24V
D
Box lug
F
110-120V
110-120V
I
208-220V
208-240V
L
277V
Contact Material
N
380-415V
440-480V
Nil
AgSnO2
U
550-600V
550-600V
H
AgCdO
11/7/07W
XMC0 Series
Definite Purpose Contactors
General Data
Rated insulation voltage
690 Vrms
Di-electric strength
2500Vrms (coil to contact & contact to contact)
Designs/conforms to
IEC 60947-4-1, GB14048.4, EN60947-4, ARI780 / 790
Agency approvals
UL,CUR file E222994
Operating position
± 15° possible, relative to normal vertical mounting plane
Operating altitude
2000 meters without derating
-20°C to 70°C
Ambient temperature
-40°C to 70°C
Shock resistance
(1/2 ~ wave) = 11ms
Contact Open: 6g ; Contact Closed: 15g
Vibration resistance (5-300Hz)
Contact Open: 2g ; Contact Closed: 4g
Electrical
Rated Operating voltage
Make capacity (230V, cos Ø=0.45)
12V-600V max.
Break capacity (230V, cos Ø=0.45)
10 x FLA
Switching frequency
360 operations/hour
Electrical endurance
(ARI 780/790)
Mechanical endurance
(ARI 780/790)
12 x FLA
200,000 cycles
3,000,000 cycles
11/7/07W
XMC0 Series
Definite Purpose Contactors
Electrical Ratings
Size
Full Load Resistive
Amps Load Amps
(FLA)
(RLA)
Compact
Standard
Locked Rotor Amps (LRA)
240VAC
480VAC
600VAC
Pole Form
Order Number
1P
1P+1shunt
2P
1P
1P+1shunt
2P
1P
1P+1shunt
2P
2P
3P
2P
3P
2P
3P
XMC0-257
XMC0-251
XMC0-252
XMC0-327
XMC0-321
XMC0-322
XMC0-407
XMC0-401
XMC0-402
XMC0-253A
XMC0-253
XMC0-323A
XMC0-323
XMC0-403A
XMC0-403
25
32
150
125
100
32
40
180
150
120
40
50
240
200
160
25
32
150
125
100
32
40
180
150
120
40
50
240
200
160
50
63
300
250
200
3P
XMC0-503
63
80
360
300
240
3P
XMC0-633
75
95
450
375
300
3P
XMC0-753
90
120
540
450
360
3P
XMC0-903
Coil Data
Pole Form
1 pole, 1 pole + 1 shunt
2 pole
3 pole, 2 pole standard (3A)
3 pole -503 & 633
3 pole -753 & 903
Inrush
VA
32
40
60
120
235
Sealed
VA
5.0
6.0
8.0
17.0
32.0
Sealed
(W)
1.5 - 3
2.5 - 4.5
3.6 - 6
3.5 - 8
6.0 - 17
Pickup
Voltage
Dropout
Voltage
< 0.8 Us* > 0.2 Us*
*Us = nominal coil voltage
11/7/07W
XMC0 Series
Definite Purpose Contactors
Dimensions
0 .8
6 .3
5 .2
4 1 47
81
5.
2
41
59.8
50
Fig 1 -1-pole/1-pole +shunt 2 pole (plastic base, 25-40 A Compact)
0.8
6.3
5.2
6.3
81
38 45
27 16
41
50
59.5
Fig 2 -1-pole/1-pole +shunt 2 pole (metal base, 25-40 A Compact)
11/7/07W
XMC0 Series
Definite Purpose Contactors
50
61
38 0.12
45 0.12
41 0.12
5.2
Fig 3 -2-pole (metal base, 25-40 A Compact)
3 pole plastic base (standard version)
16
0.8 +0.4
-0.1 6.3 +0.13
-0.03
16
35+0.50
5.3 +0.2 0
47
81.9 0.3
96 0.5
1
38 0.2
50.4 0.2
61 0.3
81.5 0.5
Fig 4 -3-pole (plastic base, 25-40 A Standard)
11/7/07W
XMC0 Series
Definite Purpose Contactors
3 pole plastic base (standard version)
16
16
0.8
6.3
35 ± 0.50
5.3 ± 0.20
47
81.9 ± 0.3
96 ± 0.5
1
81.5 ± 0.5
38 ± 0.2
50.4 ± 0.2
61 ± 0.3
Fig 5 -3-pole (plastic base, 25-40 A Standard)
0.8
6.3
92.5
82
78.5
5.2
61
78
5.2
38
50
Fig 6 -3-pole (metal base, 25-40 A Standard)
11/7/07W
XMCO Series
0.8
5.2 ± 0.2
Definite Purpose Contactors
6.3
102.6 ± 0.4
82.5 ± 0.3
80 ± 0.3
6.3
38 ± 0.2
57 ± 0.2
84 ± 0.5
83 ± 0.5
73 ± 0.3
Fig 7 -3-pole (metal base, 50-63 A Standard)
0.8
5.2
127 ± 0.4
112.5 ± 0.4
6.3
94 ± 0.4
112 ± 0.4
117.5 ± 0.4
5.2
6.3
63 ± 0.3
73 ± 0.3
Fig 8 -3-pole (metal base, 75-90 A Standard)
11/7/07W