ARI-6400F 400W Redundant Power Supply Industrial Power Supply 22.0 DC OUTPUT WIRES 0.45 8.5 19.2 6.9 Redundant 3.5 16.8 16.0 9.0 2.1 13.4 Features *Input Voltage: 90~132VAC or 180~260VAC selectable *Input Frequency: 47~63Hz *Safety: UL 1950 / CSA 1402C & CSA 950 / TUV EN60950 *Input Current: 10A at 115VAC or 6A at 230VAC max. *Inrush Current: < 50A at 100VAC, < 100A at 220VAC, < 60A *Earth Continuity Resistance: FG to HG > 0.01 ohm11 *EMI: FCC part 15 class B rules VDE at 230VAC input cold start, 25oC excluding EMI capacitors *Load Range: At 100% max. load condition in all outputs, +5V output is between 4.98V and 5.02V, +3.3V is between +3.25V and +3.35V. All other outputs are within their specified voltage accuracy ranges Output Min. Rated Max. Voltage Voltage Load Load Load Accuracy *Ripple and Noise: Peak to peak ripple and noise for +5V and +5V 7A 25A 36A 4.75~5.25V +3.3V outputs are < 60mV, and < 120mV for -5V, +12V, and +12V 2.5A 16A 17A 11.4~12.9V +5Vsb outputs -12V 0A 0.8A 0.8A -11.30~-12.6V *Line Regulation: < +/-1% for +5V, +12V, -12V, and +5Vsb -5V 0A 0.8A 0.8A -4.65~-5.25V outputs. +3.3V is +/-2% +3.3V 3A 20A 25A 3.15~3.45V *Hold Up Time: > 16ms at 115VAC or 230VAC input and max. +5Vsb 0.1A 0.75A 2A 4.8~5.2V load measured from the last AC line charging pulse to the point when +5V drops down to +4.75V *Output Power: Total DC continuous power is within 400W at < 30oC ambient temperature *Power Good Signal: Signal goes high from 100~500ms after all output DC voltages are within regulation limits *Power Redundancy: This power supply has power redundant capability *Efficiency: 65% typical, measured at nominal line and rated load *Protection: Built-in over voltage protection circuit. Trip point between 5.7~7.0V AC line off and on cycle for over voltage protection recovery latch off mode against short circuit or over load conditions *Dimensions: 19.2 x 16.8 x 22.0 cm Safety Standards www.boser.com.tw