ARTESYN NFS42-7608

NFS42 SERIES
Triple output
•
•
•
•
•
6.3 x 3.9 x 1.5 package (1U applications)
Overvoltage and short circuit protection
40W with free air convection
EN55022, EN55011 conducted emissions level B
UL, VDE, CSA and BABT safety approvals
The NFS42 series is a 40W universal input AC/DC power supply on a 6.3 x 3.9
inch card with a maximum component height of 1.5 inches for use in 1U
applications. The NFS42 series is available in three standard models with a
lower component count and larger footprint than most standard 40W models to
ensure greater reliability. The NFS42 provides 40W of output power with free air
convection cooling which can be boosted to 50W with 20CFM of air. Standard
features include overvoltage and short circuit protection. The series, with full
international safety approval and the CE mark, meets conducted emissions
EN55022 level B. The NFS42 series is designed for use in low power telecom
and industrial applications such as PABX's, industrial PC's and machine control.
[ 2 YEAR WARRANTY ]
SPECIFICATION
All specifications are typical for 110VAC input, 40 watts output at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Line regulation
LL to HL, FL
EMC CHARACTERISTICS
Main output (Output 1)
Output 2
Output 3
±1.0%
±1.0%
±0.1%
Total regulation
(See Note 5)
Main output (Output 1)
Output 2
Output 3
±3.0%
±5.0%
±5.0%
Overshoot/undershoot
At turn-on
Transient response
+5V (1.5A to 3A)
0%
Temperature coefficient All Outputs
110VAC input
230VAC input
±0.03%/°C, max.
Efficiency
110/230VAC input,
40W output
Isolation voltage
Input/output
Input/chassis
Switching frequency
Variable
Output power limit
Primary power 75W input power limit
limited
50W output power limit
6.25V ±0.75V
Yes, with auto-restart
4 Watts
INPUT SPECIFICATIONS
Approvals and
standards
(See Note 10)
16ms
100ms
70% typical
65% min.
3000VAC
1500VAC
20kHz, min.
VDE0805, EN60950, IEC950
IEC1010, UL1950, BABT
CSA C22.2 No. 950
Weight
Input voltage range
Universal input
Input frequency range
85 to 264VAC
120 to 370VDC
47 to 440Hz
Maximum input
surge current
110VAC, cold start
230VAC, cold start
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
7.5A
15A
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
Level B
Level B
criteria 2
criteria 1
criteria 1
criteria 1
criteria 2
criteria 1
GENERAL SPECIFICATIONS
Hold-up time
+5V output
Minimum output current (See Note 8)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
500mV max. dev.,
500µs recovery
Overvoltage protection
Short circuit protection
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
MTBF (See Note 8)
400g (14oz)
MIL-HDBK-217E, 25°C 230,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 6, 7)
0.66mA max.
1.2mA max.
0°C to 50°C ambient,
convection cooled
0°C to 50°C ambient,
20CFM forced air
50°C to 70°C ambient
40W
50W
Derate linearly
to 50% load
Peak (0°C to 50°C, max. 30s)
50W
Operating range,
0°C to +70°C
see derating curve
Non-operating
-40°C to +85°C
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1036
Licence No. 1485, 1650
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Relative humidity
Non-condensing
Certificate No. PS/603173
Altitude
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Vibration (See Note 9)
5Hz to 500Hz
2.4G rms approx.
PAGE 1
5% to 95% RH
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
40-50W AC/DC
40 to 50 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MAX
(1)
PEAK
(2)
FAN
(3)
RIPPLE
TOTAL
REGULATION
(4)
+5.1V (IA)
3.0A
5.0A
3.5A
50mV
±3%
+12.0V (IB)
2.0A
4.0A
2.5A
120mV
±5%
–12.0V
0.2A
0.7A
0.3A
120mV
±5%
+5.1V (IA)
2.5A
5.0A
3.5A
50mV
±3%
+24.0V (IB)
1.0A
3.0A
1.2A
240mV
±5%
–12.0V
0.2A
0.7A
0.3A
120mV
±5%
+5.1V (IA)
2.5A
5.0A
3.5A
50mV
±3%
+15.0V (IB)
1.6A
3.0A
2.0A
150mV
±5%
–15.0V
0.2A
0.7A
0.3A
150mV
±5%
MODEL NUMBER
(5)
(A)
NFS42-7608
NFS42-7627
NFS42-7610
Notes
AC mating connector
1
2
Molex type 09-50-3031 or equivalent with 2878 series or equivalent crimp
terminal.
Convection cooled, maximum 40W output power.
Peak outputs lasting less than 30 seconds with duty factor less than 10%.
During peak loading, output may go outside total regulation limits.
Maximum output power during peak loading is 50W.
3 Forced air, 20 CFM at 1 atmosphere. Total power out, 50W maximum.
4 Figure is peak-to-peak. Output noise measurements are across a 50MHz
bandwidth made using a 12 inch twisted pair, terminated with a 47µF
capacitor.
5 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits and output voltages
adjusted to their factory settings. Also, for stated regulation:
NFS42-7608 : 0.25 ≤ x ≤ 5
IA
NFS42-7627 : 0.50 ≤ x ≤ 12
Where x = —
IB
NFS42-7610 : 0.30 ≤ x ≤ 12
6 Derating curve is application specific for ambient temperatures >50°C, for
optimum reliability no part of the heatsink should exceed 110oC and no
semiconductor case temperature should exceed 115oC.
7 Caution: Allow a minimum of 1 second after disconnecting the power
when making thermal measurements.
8 Artesyn Technologies recommends a minimum load of 4 Watts to achieve
the design MTBF.
9 Three orthogonal axes, random vibration, 10 minute test for each axis.
10 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
DC mating connector
The NFS42 uses three 4-pin paralleled connectors with 0.098 inch pin spacing.
Each pin is rated at 2.5 amps. The manufacturer suggests, that for each output,
all three paralleled pins be used to minimise the current contribution of each.
Lowering the current delivered through each pin improves output regulation and
reduces pin heating which improves connector long term reliability.
Artesyn Technologies recommends, as the DC mating connector, a fourteen pin
housing placed over all twelve pins simultaneously. This connector is available
with polarising rib to prevent left or right pin misalignment. The relevant part is
Molex type is 22-01-1143 or equivalent with associated crimp terminal 08-500114 or equivalent.
0.156 (3.962) Dia. 4 Places
Pin 1
Pin 1
J2
3.15
(80.01)
J3
3.90
(99.06)
Pin 1
J4
J1
E1
1
2
PIN CONNECTIONS
J1
NFS42-7608
NFS42-7627
NFS42-7610
4.80
(121.92)
6.30
(160.02)
Pin 1
AC Neutral
AC Neutral
AC Neutral
Pin 2
AC Line
AC Line
AC Line
Pin 1
–12V
–12V
–15V
Pin 2
+12V
+24V
+15V
Pin 3
Return
Return
Return
0.75
(19.05)
0.40
(10.16)
ALL DIMENSIONS IN INCHES (mm)
Maximum component height is 1.50 (38.10 mm)
J2, J3, J4
DERATING CURVE (See Notes 6, 7, 8)
Output Power (Watts)
50W
20 CFM FORCED AIR COOLING
40W
Pin 4
+5.1V
+5.1V
+5.1V
E1
Ground
Ground
Ground
NATURAL
CONVECTION
COOLING
25W
20W
Mechanical notes
A A standard L-bracket and cover is available for mounting which contains
all screws, connectors and necessary mounting hardware. Details are on
page 83. Order part number ‘NFS50 COVER KIT’.
4W
4W MIN. LOAD REQUIRED TO ACHIEVE DESIGN MTBF
10°C
20°C
30°C
40°C
50°C
60°C
70°C
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 2
DS_NFS42_19980401.PDF
0°C