The NFS50-7608 is a 50W universal input AC/DC power supply on a 6.3 x 3.94 inch
card with a maximum component height of 1.5 inches for use in 1U applications. The
NFS50-7608 series can regulate on the auxiliary outputs down to no load making it
suitable for applications that require a heavy logic load on the main 5V output and low
nominal loads with high peak capability for drives, relays or switches on the auxiliary
outputs. The NFS50-7608 provides 50W of output power with free air convection
cooling which can be boosted to 60W with 20CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval
and the CE mark, meets conducted emissions EN55022 level A. The NFS50-7608
series is designed for use in low power data networking, computer, telecom and
industrial applications such as POS terminals, servers, PABX's, industrial PC's and
process automation.
[ 2 YEAR WARRANTY ]
SPECIFICATION
6.3 x 3.94 x 1.5 inch package (1U applications)
Overvoltage and short circuit protection
50W with free air convection cooling
Regulation to no load
Isolated output option
EN55022, EN55011 conducted emissions level A
UL, VDE and CSA safety approvals
NFS50 Medical IEC601 approved
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
+5V output
+12V tracks the 5V output
±3%
Line regulation
LL to HL at max. load
±0.3%
Total regulation
Main output (output 1)
All other outputs
(See Notes 5, 6)
±2.5%
±5.0%
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
At turn-on
Transient response
5V (2.5A to 5A)
0%
500mV max. dev.
500µs recovery to 0.5%
12V (1A to 2A)
300mV max. dev.
500µs recovery to 0.5%
Temperature coefficient All outputs
Overvoltage protection
+5V output
Output power limit
Primary power
limited
Short circuit protection
±0.03%/°C, max.
6.25V ±0.65V
90W Pin max.
60W Pout min.
Yes, with auto-restart
Universal input
Input frequency range
110VAC, cold start
230VAC, cold start
Safety ground
leakage current
132VAC, 60Hz
264VAC, 50Hz
85 to 264VAC
120 to 370VDC
PAGE 1
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
criteria
criteria
criteria
criteria
criteria
1
1
2
2
2
Input/output
Input/chassis
Switching frequency
Variable
Approvals and
standards
3000VAC
1500VAC
25kHz to 250kHz
VDE0805, EN60950, IEC950
IEC1010, CSA C22.2 No. 950
Weight
MTBF (See Note 7)
16ms
100ms
70%, typ.
Isolation voltage
400g (14oz)
MIL-HDBK-217E, 25°C 160,000 hours
Thermal performance
Operating range
0°C to +70°C
(See derating curve)
Non-operating
–40°C to +85°C
0°C to 50°C ambient temp.,
50W
Convection cooled
0°C to 50°C ambient,
60W
Forced air @ 20 CFM
50°C to 70°C ambient Derate linearly
to 50% load
Peak (30 seconds)
60W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Vibration (See Note 9)
5Hz to 500Hz
2.4G rms (approx)
10A, max.
20A max.
0.2mA, max.
0.4mA, max.
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD air
Perf.
Perf.
Perf.
Perf.
Perf.
110VAC, 50W output power
230VAC, 50W output power
Efficiency
47 to 440Hz
Input surge current
4
3
3
3
3
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input voltage range
level
level
level
level
level
GENERAL SPECIFICATIONS
Hold-up time
Overshoot/undershoot
EN61000-4-2,
EN61000-4-5,
EN61000-4-4,
EN61000-4-3,
EN61000-4-6,
Level A
Level A
Perf. criteria 1
5% to 95% RH
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
50-60W AC/DC
50 to 60 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENTS
OUTPUT
RIPPLE
MAX(1)
VOLTAGE
+5.1V (I1)
(6)
PEAK
(2)
FAN
TOTAL
(4)
(3)
5.0A
7.0A
7.0A
50mV
±2.5%
+12.0V (I2)
2.0A
5.0A
2.5A
120mV
±5.0%
-12.0V
0.5A
1.0A
0.7A
120mV
±5.0%
Notes
1
2
Convection cooled, maximum 50W output power.
Peak outputs lasting less than 30 seconds with duty factor less than 10%.
During peak loading output may go outside total regulation limits.
Maximum output during peak loading is 60 Watts.
3 Forced air, 20 CFM at 1 atmosphere.
4 Figure is peak-to-peak. Output noise measurements are across a 50MHz
bandwidth made using a 12” twisted pair, terminated with a 47µF
capacitor.
5 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits and output voltages
adjusted to their factory settings. Also, for stated I(2) regulation: I(1)/I(2)≤5.
6 A minimum load of 0.5 Amps is required on the +5.1V output to obtain full
current from the -12V output.
7 Derating curve is application specific for ambient temperatures > 50°C, for
optimum reliability no part of the heatsink should exceed 110oC and no
semiconductor case temperature should exceed 115oC.
8 Caution: Allow a minimum of 1 second after disconnecting the power
when making thermal measurements.
9 Three orthogonal axes, random vibration, ten minute test for each axis.
10 A 5 Watt minimum load is recommended to achieve design MTBF.
11 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
MODEL
REGULATION(5,6)
NUMBER
NFS50-7608
PIN CONNECTIONS
J1
NFS50-7608
Pin 1
AC Line
Pin 2
AC Neutral
J2, J3, J4
Pin 1
-12V
Pin 2
+12V
Pin 3
Return
Pin 4
+5.1V
E1
Pin 1
Ground
0.156 (3.96) Dia. 4 Places
PIN1
PIN1
MAX HEIGHT 38.1mm
J2
OUTPUT
ADJUST
AC mating connector
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminal.
3.15
(80.0)
J3
J1
J4
2
1
DC mating connector
Molex 22-01-1043 or equivalent with Molex
08-50-0031 or equivalent crimp terminal.
(12)
3.94
(100.1)
PIN1
E1
4.80
(121.9)
6.30
(160.0)
0.75
(19.0)
0.40
(10.2)
ALL DIMENSIONS ARE IN INCHES (mm)
Maximum component height is 1.5 (38.1)
DERATING CURVE
Output Power (Watts)
60W
20 CFM FORCED AIR COOLING
50W
30W
NATURAL
CONVECTION
COOLING
25W
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010
File No. 10401-3336-1036 Licence No 1485 and 1650
5W MINIMUM LOAD REQUIRED TO ACHIEVE DESIGN MTBF
10°C
20°C
30°C
40°C
50°C
60°C
70°C
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising