ARTESYN NLS110

NLS110-9602J
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies
1
•
•
•
•
•
7.0 x 4.25 x 1U package
Overvoltage and short circuit protection
110 W with 20 CFM
90 Vac to 264 Vac universal input range
EN55022 conducted emissions level B, radiated
emissions level A
• UL, VDE and CSA safety approvals
• CE mark
• Available RoHS compliant
The NLS110-9602J is a 110 W universal input ac-dc power supply on a 7 x 4.25 inch
card. The NLS110-9602J has proven itself to be highly reliable and versatile product for
a wide range of communication and industrial applications, with a very high peak
current capability on each output for drive and motor applications. The NLS110-9602J
provides 80 W of output power with free air convection cooling which can be boosted
to 110 W with 20 CFM of air. Standard features include overvoltage and short circuit
protection. The NLS110-9602J with full international safety approval and the CE mark,
meets conducted emissions EN55022 level B. The NLS110-9602J is designed for use
in low power data networking, computer, telecom and industrial applications such as
servers, thermal printers, storage devices, vending machines and POS equipment.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
Line and load
(See table)
Rise Time
At turn-on
1.0 s, max.
Transient response
(See table)
Temperature coefficient
±0.02%/°C
Overvoltage protection
+5.1 V
125%, ±10%
Short circuit protection
Cyclic operation
Yes with auto
recovery
Universal input
90-264 Vac
Input frequency range
47-440 Hz
Input surge current
(cold start)
120 Vac
230 Vac
Safety ground
leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
Input current
120
120
230
230
Input fuse
UL/IEC127
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
120 Vac @ 60 Hz
35 ms @ 80 W
25 ms @ 110 W
Efficiency
120 Vac @ 110 W
70% min.
Isolation voltage
Input/output
Input/chassis
3000 Vac
1500 Vac
Approvals and
standards
Vac
Vac
Vac
Vac
Thermal performance
0.45 mA
0.75 mA
80 W
110 W
80 W
110 W
0.95
1.35
0.53
0.75
A
A
A
A
rms
rms
rms
rms
F3.15A H, 250 Vac
(11)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level B
Level A
Compliant
Level
Level
Level
Level
Level
Level
3
3
3
3
3
3
383 g (13.5 oz.)
MIL-HDBK-217F
ENVIRONMENTAL SPECIFICATIONS
18 A max.
35 A max.
@
@
@
@
EN60950, VDE0805, IEC950
UL1950, CSA C22.2 No. 950
Weight
MTBF (@ 25 ˚C)
INPUT SPECIFICATIONS
Input voltage range
Hold-up time
220,000 hours min.
(6,8)
Operating ambient,
0 °C to +50 °C
(see derating curve)
Non-operating
–40 °C to +85 °C
+50 °C to +70 °C,
Derate to
amb. convection cooled
50% load
0 °C to +50 °C,
80 W
amb. convection cooled
0 °C to +50 °C ambient,
110 W
150 LFM forced air
Peak (0 °C to +50 °C, 60 s) (See Note 4)
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 7)
5-500 Hz
Shock
per MIL-STD-810E
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms peak
516.4 Part IV
File Name: nls110.pdf Rev (02): 08 Nov 2005
NLS110-9602J
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
VOLTAGE
OUTPUT CURRENTS
MAX
(1)
PEAK
(2)
FAN
(3)
3
4
5
6
7
8
9
10
11
12
13
14
TOTAL
REGULATION
(4)
+5.1 V
8A
20 A
10 A
50 mV
±2.0%
+24 V
3.5 A
4.5 A
4.5 A
240 mV
±5.0%
+12 V
4.5 A
9A
5A
120 mV
±3.0%
–12 V
0.5 A
1.5 A
1A
120 mV
±3.0%
Notes
1
2
RIPPLE
(5)
MODEL NUMBERS (12,13,14)
NLS110-9602J
TRANSIENT RESPONSE
Convection cooled, 80 W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%.
Total peak power must not exceed 110 W.
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
Amplitude is peak-to-peak. Output ripple is measured across a 20 MHz
bandwidth using a 12 inch twisted pair terminated with a 10 µF capacitor.
Total regulation is defined as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits and output voltages
adjusted to their factory settings.
Derating curve is application specific for ambient temperatures >50 °C.
Three orthogonal axes, random vibration, 10 minute test for each axis.
For optimum reliability no part of the heatsink should exceed 100 ºC and
no semiconductor case temperature should exceed 115 ºC.
Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
The EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond each
edge, using an unshielded cable. No external filtering is required during
conducted emissions testing but some applications may require additional
filtering to achieve system compliance. A line choke, (ac input cords looped
twice through an EMI suppression toroid) was used during radiated
emissions testing. Considerable radiated testing in 1U six-sided boxes has
shown that units can meet level B in typical systems. Application support
is available from the factory to assist with EMI compliance.
Requires a minimum mounting stand-off of 6.35 mm (0.25 inches) in the
end use product.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
NLS110-9602J
+5.1 V (7.5 A to 1 0A)
+24 V (1.5 A to 3 A)
+12 V (2.5 A to 5 A)
-12 V (0.5 A to 1 A)
150 mV peak,
1 ms recovery
300 mV peak,
1 ms recovery
100 mV peak,
0.5 ms recovery
100 mV peak,
0.5 ms recovery
DERATING CURVE
Output Power (Watts)
110W
150 LFM FORCED
AIR COOLING
80W
NATURAL
CONVECTION
COOLING
55W
40W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
AC INPUT
OUTPUT PIN CONNECTIONS
J2
FUNCTION
Pin 1
+5.1 V
Pin 2
+5.1 V
Pin 3
Return
Pin 4
Return
Pin 5
Return
Pin 6
Return
Pin 7
+12 V
Pin 8
+12 V
Pin 9
+24 V
Pin 10
PFD
Pin 11
-12 V Return
Pin 12
-12 V
PIN
Pin 1
Pin 2
Pin 3
Pin 1
INPUT
CONNECTIONS
J1
AC Neutral
No Connection
AC Line
J4
Safety Earth
5V OUTPUT
4.75V
4.75V
HIGH
3.5V MIN
LOW
PFD SIGNAL
0-0.4 MAX
T3
T2
T1
Power fail detect signal
50 ms≤T1≤200 ms
T2 will vary with line and load
T3≥3 ms
Pout: 110 W
PFD output is an open collector
which will sink ≤40 mA in the low
state.
File Name: nls110.pdf Rev (02): 08 Nov 2005
NLS110-9602J
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
2
7.00 (177.80)
6.500 (165.100)
4
3
J4
1
T1 (REF)
12
4.25
(107.95)
T2 (REF)
3.750
(95.250)
Recommended direction
for forced air relative to
power supply orientation
shown below.
1
2
3
4
J2
Optimum.
Very good.
Not recommended.
Not recommended.
F1
1
3
J1
1
0.25 (6.35)
0.25 (6.35)
J5
2
1
TOLERANCE: .XXX: ±0.005 (0.127)
.XX: ±0.02 (0.51)
ALL DIMENSIONS IN INCHES (mm)
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 or equivalent.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J2) connector type
12 position Molex Spox type 26-48-1125
or equivalent.
DC (J2) mating connector type
Molex Spox type 26-03-3121 and
contact 08-52-0113.
Earth (J4) connector type
Male 0.250 quick disconnect.
Earth (J4) mating connector type
Molex 90028.
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-0186
Licence No.130253
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note
www.artesyn.com
File Name: nls110.pdf Rev (02): 08 Nov 2005