NLS110-9602J Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies 1 • • • • • 7.0 x 4.25 x 1U package Overvoltage and short circuit protection 110 W with 20 CFM 90 Vac to 264 Vac universal input range EN55022 conducted emissions level B, radiated emissions level A • UL, VDE and CSA safety approvals • CE mark • Available RoHS compliant The NLS110-9602J is a 110 W universal input ac-dc power supply on a 7 x 4.25 inch card. The NLS110-9602J has proven itself to be highly reliable and versatile product for a wide range of communication and industrial applications, with a very high peak current capability on each output for drive and motor applications. The NLS110-9602J provides 80 W of output power with free air convection cooling which can be boosted to 110 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The NLS110-9602J with full international safety approval and the CE mark, meets conducted emissions EN55022 level B. The NLS110-9602J is designed for use in low power data networking, computer, telecom and industrial applications such as servers, thermal printers, storage devices, vending machines and POS equipment. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 °C unless otherwise stated OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Total regulation Line and load (See table) Rise Time At turn-on 1.0 s, max. Transient response (See table) Temperature coefficient ±0.02%/°C Overvoltage protection +5.1 V 125%, ±10% Short circuit protection Cyclic operation Yes with auto recovery Universal input 90-264 Vac Input frequency range 47-440 Hz Input surge current (cold start) 120 Vac 230 Vac Safety ground leakage current 120 Vac, 60 Hz 230 Vac, 50 Hz Input current 120 120 230 230 Input fuse UL/IEC127 EMC CHARACTERISTICS Conducted emissions Radiated emissions Harmonic current emission correction ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity 120 Vac @ 60 Hz 35 ms @ 80 W 25 ms @ 110 W Efficiency 120 Vac @ 110 W 70% min. Isolation voltage Input/output Input/chassis 3000 Vac 1500 Vac Approvals and standards Vac Vac Vac Vac Thermal performance 0.45 mA 0.75 mA 80 W 110 W 80 W 110 W 0.95 1.35 0.53 0.75 A A A A rms rms rms rms F3.15A H, 250 Vac (11) EN55022, FCC part 15 EN55022, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-2 EN61000-4-5 EN61000-4-4 EN61000-4-3 EN61000-4-6 Level B Level A Compliant Level Level Level Level Level Level 3 3 3 3 3 3 383 g (13.5 oz.) MIL-HDBK-217F ENVIRONMENTAL SPECIFICATIONS 18 A max. 35 A max. @ @ @ @ EN60950, VDE0805, IEC950 UL1950, CSA C22.2 No. 950 Weight MTBF (@ 25 ˚C) INPUT SPECIFICATIONS Input voltage range Hold-up time 220,000 hours min. (6,8) Operating ambient, 0 °C to +50 °C (see derating curve) Non-operating –40 °C to +85 °C +50 °C to +70 °C, Derate to amb. convection cooled 50% load 0 °C to +50 °C, 80 W amb. convection cooled 0 °C to +50 °C ambient, 110 W 150 LFM forced air Peak (0 °C to +50 °C, 60 s) (See Note 4) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 7) 5-500 Hz Shock per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV File Name: nls110.pdf Rev (02): 08 Nov 2005 NLS110-9602J Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT VOLTAGE OUTPUT CURRENTS MAX (1) PEAK (2) FAN (3) 3 4 5 6 7 8 9 10 11 12 13 14 TOTAL REGULATION (4) +5.1 V 8A 20 A 10 A 50 mV ±2.0% +24 V 3.5 A 4.5 A 4.5 A 240 mV ±5.0% +12 V 4.5 A 9A 5A 120 mV ±3.0% –12 V 0.5 A 1.5 A 1A 120 mV ±3.0% Notes 1 2 RIPPLE (5) MODEL NUMBERS (12,13,14) NLS110-9602J TRANSIENT RESPONSE Convection cooled, 80 W maximum. Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. Forced air, 20 CFM at 1 atmosphere, 110 W maximum. Amplitude is peak-to-peak. Output ripple is measured across a 20 MHz bandwidth using a 12 inch twisted pair terminated with a 10 µF capacitor. Total regulation is defined as the static output regulation at 25 °C, including initial tolerance, line voltage within stated limits and output voltages adjusted to their factory settings. Derating curve is application specific for ambient temperatures >50 °C. Three orthogonal axes, random vibration, 10 minute test for each axis. For optimum reliability no part of the heatsink should exceed 100 ºC and no semiconductor case temperature should exceed 115 ºC. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. The EMI specifications reference measurements made with the power supply mounted on a grounded metal sheet extending 1 inch beyond each edge, using an unshielded cable. No external filtering is required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. A line choke, (ac input cords looped twice through an EMI suppression toroid) was used during radiated emissions testing. Considerable radiated testing in 1U six-sided boxes has shown that units can meet level B in typical systems. Application support is available from the factory to assist with EMI compliance. Requires a minimum mounting stand-off of 6.35 mm (0.25 inches) in the end use product. The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. NLS110-9602J +5.1 V (7.5 A to 1 0A) +24 V (1.5 A to 3 A) +12 V (2.5 A to 5 A) -12 V (0.5 A to 1 A) 150 mV peak, 1 ms recovery 300 mV peak, 1 ms recovery 100 mV peak, 0.5 ms recovery 100 mV peak, 0.5 ms recovery DERATING CURVE Output Power (Watts) 110W 150 LFM FORCED AIR COOLING 80W NATURAL CONVECTION COOLING 55W 40W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC INPUT OUTPUT PIN CONNECTIONS J2 FUNCTION Pin 1 +5.1 V Pin 2 +5.1 V Pin 3 Return Pin 4 Return Pin 5 Return Pin 6 Return Pin 7 +12 V Pin 8 +12 V Pin 9 +24 V Pin 10 PFD Pin 11 -12 V Return Pin 12 -12 V PIN Pin 1 Pin 2 Pin 3 Pin 1 INPUT CONNECTIONS J1 AC Neutral No Connection AC Line J4 Safety Earth 5V OUTPUT 4.75V 4.75V HIGH 3.5V MIN LOW PFD SIGNAL 0-0.4 MAX T3 T2 T1 Power fail detect signal 50 ms≤T1≤200 ms T2 will vary with line and load T3≥3 ms Pout: 110 W PFD output is an open collector which will sink ≤40 mA in the low state. File Name: nls110.pdf Rev (02): 08 Nov 2005 NLS110-9602J Quad output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110 W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm Mechanical Notes A All dimensions are in inches (mm). 2 7.00 (177.80) 6.500 (165.100) 4 3 J4 1 T1 (REF) 12 4.25 (107.95) T2 (REF) 3.750 (95.250) Recommended direction for forced air relative to power supply orientation shown below. 1 2 3 4 J2 Optimum. Very good. Not recommended. Not recommended. F1 1 3 J1 1 0.25 (6.35) 0.25 (6.35) J5 2 1 TOLERANCE: .XXX: ±0.005 (0.127) .XX: ±0.02 (0.51) ALL DIMENSIONS IN INCHES (mm) Input and output connectors Mating connectors AC (J1) connector type Molex 26-60-4030 or equivalent. AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) connector type 12 position Molex Spox type 26-48-1125 or equivalent. DC (J2) mating connector type Molex Spox type 26-03-3121 and contact 08-52-0113. Earth (J4) connector type Male 0.250 quick disconnect. Earth (J4) mating connector type Molex 90028. International Safety Standard Approvals VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-0186 Licence No.130253 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: ✔ Application Note www.artesyn.com File Name: nls110.pdf Rev (02): 08 Nov 2005