VISHAY RS3G

RS3A thru RS3K
Vishay General Semiconductor
Surface Mount Fast Switching Rectifier
FEATURES
• Low profile package
• Ideal for automated placement
• Glass passivated chip junction
• Fast switching for high efficiency
• High forward surge capability
• Meets MSL level 1, per J-STD-020, LF maximum
peak of 260 °C
DO-214AB (SMC)
• Solder dip 260 °C, 40 s
• Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
TYPICAL APPLICATIONS
For use in fast switching rectification of power supply,
inverters, converters, and freewheeling diodes for
consumer, automotive and telecommunication.
PRIMARY CHARACTERISTICS
IF(AV)
3.0 A
VRRM
50 V to 800 V
IFSM
100 A
MECHANICAL DATA
Case: DO-214AB (SMC)
trr
150 ns, 250 ns, 500 ns
VF
1.3 V
TJ max.
150 °C
Epoxy meets UL 94V-0 flammability rating
Terminals: Matte tin plated leads, solderable per
J-STD-002 and JESD22-B102
E3 suffix for consumer grade, meets JESD 201 class
1A whisker test, HE3 suffix for high reliability grade
(AEC Q101 qualified), meets JESD 201 class 2
whisker test
Polarity: Color band denotes cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
Device marking code
Maximum repetitive peak reverse voltage
VRRM
Maximum RMS voltage
RS3A
RS3B
RS3D
RS3G
RS3J
RS3K
UNIT
RA
RB
RD
RG
RJ
RK
50
100
200
400
600
800
V
VRMS
35
70
140
280
420
500
V
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
V
Maximum average forward rectified current at TL = 75 °C
IF(AV)
3.0
A
Peak forward surge current 8.3 ms single half sine-wave
superimposed on rated load
IFSM
100
A
TJ, TSTG
- 55 to + 150
°C
Operating junction and storage temperature range
Document Number: 88709
Revision: 11-Apr-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
RS3A thru RS3K
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Maximum instantaneous
forward voltage
2.5 A
SYMBOL
RS3A
RS3B
RS3D
RS3G
RS3J
RS3K
UNIT
VF
1.3
V
10
250
µA
Maximum DC reverse current at
rated DC blocking voltage
TA = 25 °C
TA = 125 °C
IR
Maximum reverse recovery time
IF = 0.5 A, IR = 1.0 A,
Irr = 0.25 A
trr
150
Typical junction capacitance
4.0 V, 1 MHz
CJ
44
250
500
34
ns
pF
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
RS3A
RS3B
RS3D
RθJA
RθJL
Typical thermal resistance (1)
RS3G
RS3J
RS3K
50
15
UNIT
°C/W
Note:
(1) Thermal resistance from junction to ambient and from junction to lead mounted on P.C.B. with 0.3 x 0.3" (8.0 x 8.0 mm) copper pad area
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
REFFERED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
RS3J-E3/57T
0.211
57T
850
7" diameter plastic tape and reel
RS3J-E3/9AT
0.211
9AT
3500
13" diameter plastic tape and reel
RS3JHE3/57T (1)
0.211
57T
850
7" diameter plastic tape and reel
RS3JHE3/9AT (1)
0.211
9AT
3500
13" diameter plastic tape and reel
Note:
(1) Automotive grade AEC Q101 qualified
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
150
Resistive or Inductive Load
Peak Forward Surge Current /A)
Average Forward Rectified Current (A)
3.0
2.5
2.0
1.5
1.0
P.C.B. Mounted
0.3 x 0.3" (8.0 x 8.0 mm)
Copper Pad Areas
0.5
0
TL = 75 °C
8.3 ms Single Half Sine-Wave
125
100
75
50
25
0
0
25
50
75
100
125
150
1
10
100
Lead Temperature (°C)
Number of Cycles at 60 Hz
Figure 1. Forward Current Derating Curve
Figure 2. Maximum Non-Repetitive Peak Forward Surge Current
www.vishay.com
2
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
Document Number: 88709
Revision: 11-Apr-08
RS3A thru RS3K
Vishay General Semiconductor
100
TJ = 125 °C
Junction Capacitance (pF)
Instantaneous Forward Current (A)
100
10
TJ = 25 °C
Pulse Width = 300 µs
1 % Duty Cycle
1
TJ = - 40 °C
0.1
0.4
RS3J to RS3K
10
1
0.6
0.8
1.0
1.2
1.6
1.4
1.8
2.0
1
10
100
Instantaneous Forward Voltage (V)
Reverse Voltage (V)
Figure 3. Typical Instantaneous Forward Characteristics
Figure 5. Typical Junction Capacitance
100
Transient Thermal Impedance (°C/W)
100
Instantaneous Reverse Current (µA)
RS3A to RS3G
TJ = 125 °C
10
TJ = 75 °C
1
TJ = 25 °C
0.1
20
40
60
80
10
1
0.1
0.01
0.01
0
Mounted on 0.20 x 0.27" (5 x 7 mm)
Copper Pad Areas
100
1
0.1
10
100
Percent of Rated Peak Reverse Voltage (%)
t - Pulse Duration (s)
Figure 4. Typical Reverse Characteristics
Figure 6. Typical Transient Thermal Impedance
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
DO-214AB (SMC)
Cathode Band
Mounting Pad Layout
0.185 (4.69) MAX.
0.246 (6.22)
0.220 (5.59)
0.126 (3.20)
0.114 (2.90)
0.126 (3.20) MIN.
0.280 (7.11)
0.260 (6.60)
0.060 (1.52) MIN.
0.012 (0.305)
0.006 (0.152)
0.320 REF.
0.103 (2.62)
0.079 (2.06)
0.060 (1.52)
0.030 (0.76)
0.008 (0.2)
0 (0)
0.320 (8.13)
0.305 (7.75)
Document Number: 88709
Revision: 11-Apr-08
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
3
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1