RS3A thru RS3K Vishay General Semiconductor Surface Mount Fast Switching Rectifier FEATURES • Low profile package • Ideal for automated placement • Glass passivated chip junction • Fast switching for high efficiency • High forward surge capability • Meets MSL level 1, per J-STD-020, LF maximum peak of 260 °C DO-214AB (SMC) • Solder dip 260 °C, 40 s • Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC TYPICAL APPLICATIONS For use in fast switching rectification of power supply, inverters, converters, and freewheeling diodes for consumer, automotive and telecommunication. PRIMARY CHARACTERISTICS IF(AV) 3.0 A VRRM 50 V to 800 V IFSM 100 A MECHANICAL DATA Case: DO-214AB (SMC) trr 150 ns, 250 ns, 500 ns VF 1.3 V TJ max. 150 °C Epoxy meets UL 94V-0 flammability rating Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD22-B102 E3 suffix for consumer grade, meets JESD 201 class 1A whisker test, HE3 suffix for high reliability grade (AEC Q101 qualified), meets JESD 201 class 2 whisker test Polarity: Color band denotes cathode end MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL Device marking code Maximum repetitive peak reverse voltage VRRM Maximum RMS voltage RS3A RS3B RS3D RS3G RS3J RS3K UNIT RA RB RD RG RJ RK 50 100 200 400 600 800 V VRMS 35 70 140 280 420 500 V Maximum DC blocking voltage VDC 50 100 200 400 600 800 V Maximum average forward rectified current at TL = 75 °C IF(AV) 3.0 A Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load IFSM 100 A TJ, TSTG - 55 to + 150 °C Operating junction and storage temperature range Document Number: 88709 Revision: 11-Apr-08 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 1 RS3A thru RS3K Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS Maximum instantaneous forward voltage 2.5 A SYMBOL RS3A RS3B RS3D RS3G RS3J RS3K UNIT VF 1.3 V 10 250 µA Maximum DC reverse current at rated DC blocking voltage TA = 25 °C TA = 125 °C IR Maximum reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 150 Typical junction capacitance 4.0 V, 1 MHz CJ 44 250 500 34 ns pF THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL RS3A RS3B RS3D RθJA RθJL Typical thermal resistance (1) RS3G RS3J RS3K 50 15 UNIT °C/W Note: (1) Thermal resistance from junction to ambient and from junction to lead mounted on P.C.B. with 0.3 x 0.3" (8.0 x 8.0 mm) copper pad area ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) REFFERED PACKAGE CODE BASE QUANTITY DELIVERY MODE RS3J-E3/57T 0.211 57T 850 7" diameter plastic tape and reel RS3J-E3/9AT 0.211 9AT 3500 13" diameter plastic tape and reel RS3JHE3/57T (1) 0.211 57T 850 7" diameter plastic tape and reel RS3JHE3/9AT (1) 0.211 9AT 3500 13" diameter plastic tape and reel Note: (1) Automotive grade AEC Q101 qualified RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 150 Resistive or Inductive Load Peak Forward Surge Current /A) Average Forward Rectified Current (A) 3.0 2.5 2.0 1.5 1.0 P.C.B. Mounted 0.3 x 0.3" (8.0 x 8.0 mm) Copper Pad Areas 0.5 0 TL = 75 °C 8.3 ms Single Half Sine-Wave 125 100 75 50 25 0 0 25 50 75 100 125 150 1 10 100 Lead Temperature (°C) Number of Cycles at 60 Hz Figure 1. Forward Current Derating Curve Figure 2. Maximum Non-Repetitive Peak Forward Surge Current www.vishay.com 2 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88709 Revision: 11-Apr-08 RS3A thru RS3K Vishay General Semiconductor 100 TJ = 125 °C Junction Capacitance (pF) Instantaneous Forward Current (A) 100 10 TJ = 25 °C Pulse Width = 300 µs 1 % Duty Cycle 1 TJ = - 40 °C 0.1 0.4 RS3J to RS3K 10 1 0.6 0.8 1.0 1.2 1.6 1.4 1.8 2.0 1 10 100 Instantaneous Forward Voltage (V) Reverse Voltage (V) Figure 3. Typical Instantaneous Forward Characteristics Figure 5. Typical Junction Capacitance 100 Transient Thermal Impedance (°C/W) 100 Instantaneous Reverse Current (µA) RS3A to RS3G TJ = 125 °C 10 TJ = 75 °C 1 TJ = 25 °C 0.1 20 40 60 80 10 1 0.1 0.01 0.01 0 Mounted on 0.20 x 0.27" (5 x 7 mm) Copper Pad Areas 100 1 0.1 10 100 Percent of Rated Peak Reverse Voltage (%) t - Pulse Duration (s) Figure 4. Typical Reverse Characteristics Figure 6. Typical Transient Thermal Impedance PACKAGE OUTLINE DIMENSIONS in inches (millimeters) DO-214AB (SMC) Cathode Band Mounting Pad Layout 0.185 (4.69) MAX. 0.246 (6.22) 0.220 (5.59) 0.126 (3.20) 0.114 (2.90) 0.126 (3.20) MIN. 0.280 (7.11) 0.260 (6.60) 0.060 (1.52) MIN. 0.012 (0.305) 0.006 (0.152) 0.320 REF. 0.103 (2.62) 0.079 (2.06) 0.060 (1.52) 0.030 (0.76) 0.008 (0.2) 0 (0) 0.320 (8.13) 0.305 (7.75) Document Number: 88709 Revision: 11-Apr-08 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 3 Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 11-Mar-11 www.vishay.com 1