H HiTRON 2007/09/18 CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS SINGLE OUTPUT HAS50S SERIES FEATURES: CHASSIS-MOUNT AC/DC MODULAR POWER SUPPLIES UNIVERSAL AC INPUT RANGE COMPACT IN SIZE MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR PUB.22 / FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: 90-264Vac typical. Nominal: 115/230Vac. Input Frequency: 47-63 Hz. (Nominal 50/60 Hz.) Input Current: 0.77A @115Vac./0.39A @230Vac. Inrush Current: 34A(peak) or 4.8(rms)@230Vac typical. Input Fuse: Use internal fuse. Dielectric Withstand: Meet IEC950. 3,000Vac-Output/Input. 1,500Vac-Input/GND. 500Vac-Output/GND. EMI: Meet CISPR PUB.22 / FCC Class B. Hold-up time: 19 mS @115Vac, 80mS @230Vac typical. Earth Leakage: Less than 0.52mA @230Vac. Remote On/Off: ON(Enable)=Open. OFF(Disable)=Short. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart Output Wattage: 50 Watts typical. Line Regulation: Various with output voltage. 0.1-0.5% typical. Load Regulation: Various with output voltage. ±1.0-2.0% typical. Noise & ripple: 1.0% typical peak to peak. OVP: Built-in on main output. Adjustability: Available at main output. Overload Protection (OLP): Fully protected against output overload and short circuit. Typical 120-150% max. load. Consult the factory for special OLP setting. GENERAL SPECIFICATION Efficiency: 72%-85% typical various with output voltage. Switching Frequency: 63K Hz. Circuit Topology: Fixed Frequency Flyback circuit. Transient Response: Peak deviation 200mV, Recovery time <3mSec. @ 25% step load change. Case: Impact resistant thermo-plastic enclosure. Safety Standard: EN60950/ UL1950 Class I or Class II. Power Density: 4.1 Watts. / Cubic inch. MTBF: 110,000Hrs. Mil Std 217, 25°C. Operating Temperature: -10°C to +75°C range. –10°C to +50°C @ full load without derating. From+50°C derating linearly to half load @+75°C (Refer to the Derating Chart). Storage Temperature: -20°C to +85°C. Temperature Coefficient: ± 0.03% /°C. Cooling: Convection cooling for <+50°C @ full load. At least 100LFM moving air is recommended for full load >+50°C in a confined area. Commercial Grade only. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load. In application Due to requests in market and advances in technology, specifications subject to change without notice. -13- OUTPUT VOLTAGE/ CURRENT RATINGS CHART SINGLE OUTPUT MODEL NO. HAS50-S033075 HAS50-S050060 HAS50-S120042 HAS50-S150035 HAS50-S240021 Symbols: "★" OVP built-in. MAIN O/P VO1 @ ★ TYP. 7.5A 6.0A 4.2A 3.5A 2.1A VOLT. +3.3V +5.0V +12.0V +15.0V +24.0V "@" Adjustable. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 378.0g (13.3 Oz.) PIN ASSIGNMENT PIN NO. P1-L P1-N P1-G P2-1 P2-2 P2-3 P2-4 P2-5 P2-6 SINGLE O/P AC-L AC-N AC-G REMOTE ON/OFF NC +VO1 +VO1 DC COM DC COM DERATING CHART -14-