CHASSIS-MOUNT UNIVERSAL INPUT AC-DC ENCAPSULATED
MODULAR POWER SUPPLIES 50 WATTS SINGLE OUTPUT
HAS50S SERIES
FEATURES:
„
„
„
„
„
„
CHASSIS-MOUNT AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL AC INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical. Nominal: 115/230Vac.
Input Frequency: 47-63 Hz. (Nominal 50/60 Hz.)
Input Current: 0.77A @115Vac./0.39A @230Vac.
Inrush Current: 34A(peak) or 4.8(rms)@230Vac typical.
Input Fuse: Use internal fuse.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22 / FCC Class B.
Hold-up time: 19 mS @115Vac, 80mS @230Vac typical.
Earth Leakage: Less than 0.52mA @230Vac.
Remote On/Off:
ON(Enable)=Open.
OFF(Disable)=Short.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart
Output Wattage: 50 Watts typical.
Line Regulation: Various with output voltage.
0.1-0.5% typical.
Load Regulation: Various with output voltage.
±1.0-2.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: Available at main output.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
Typical 120-150% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 72%-85% typical various with output voltage.
Switching Frequency: 63K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Peak deviation 200mV,
Recovery time <3mSec. @ 25% step load change.
Case: Impact resistant thermo-plastic enclosure.
Safety Standard: EN60950/ UL1950 Class I or Class II.
Power Density: 4.1 Watts. / Cubic inch.
MTBF: 110,000Hrs. Mil Std 217, 25°C.
Operating Temperature: -10°C to +75°C range.
–10°C to +50°C @ full load without derating.
From+50°C derating linearly to half load @+75°C
(Refer to the Derating Chart).
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.03% /°C.
Cooling: Convection cooling for <+50°C @ full load.
At least 100LFM moving air is recommended
for full load >+50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
In application
Due to requests in market and advances in technology, specifications subject to change without notice.
-13-
OUTPUT VOLTAGE/ CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HAS50-S033075
HAS50-S050060
HAS50-S120042
HAS50-S150035
HAS50-S240021
Symbols: "★" OVP built-in.
MAIN O/P VO1 @ ★
TYP.
7.5A
6.0A
4.2A
3.5A
2.1A
VOLT.
+3.3V
+5.0V
+12.0V
+15.0V
+24.0V
"@" Adjustable.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 378.0g (13.3 Oz.)
PIN ASSIGNMENT
PIN NO.
P1-L
P1-N
P1-G
P2-1
P2-2
P2-3
P2-4
P2-5
P2-6
SINGLE O/P
AC-L
AC-N
AC-G
REMOTE ON/OFF
NC
+VO1
+VO1
DC COM
DC COM
DERATING CHART