HITRON HEPG98-S190051-8

H HiTRON
HARMONIC CORRECTION (PFC) AC/DC EXTERNAL DESKTOP
ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 100 WATTS
GREEN POWER SWITCHING POWER SUPPLIES HEPG98 SERIES
FEATURES:
„
ACCOMMODATE UNIVERSAL AC INPUT
„
DESKTOP IEC320-3PL/2P AC RECEPTACLE
„
GREEN POWER
„
MEET IEC61000-3-2 HARMONIC CORRECTION
„
EMI MEET EN55022/FCC CLASS B
„
MEET UNIVERSAL SAFETY STANDARDS
„
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 100 Watts.
Output Connector: Optional.
Line Regulation: 0.2 % typical.
Load Regulation: ± 2.5% typical.
Noise & Ripple: 1% typical peak to peak.
OVP: Built-in. (Latch)
Over Temp. Protection (OTP): Installed.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 110-135% rating output wattage.
Consult the factory for OLP setting.
Power Factor Correction (PFC) installed.
Input Connector: IEC320-3PL/2P AC receptacle.
Input Frequency: 50/60Hz.
Inrush Current: Typ. 10.6Arms @230Vac 50Hz.
Input Current: 0.97A@115Vac/0.5A@230Vac
Dielectric Withstand: Meet IEC60950-1.
EMI: Meet EN55022/FCC Class B.
Hold-up Time: 15mS @115Vac/ 28mS@230Vac typical.
Green Power: 0.29W @ 132Vac/ 0.45W @264Vac.
Earth Leakage: Less than 0.24mA.
GENERAL SPECIFICATION
Efficiency: 88-90% typical.
Switching Frequency: 25-65 KHz.
Circuit Topology: Fixed Flyback Circuit.
Transient Response: Output voltage returns in less than
1mS following a 25% load change.
Safety Standard: Meet UL60950-1/EN60950-1 Class I or II.
Harmonic Current Emission, EN61000-3-2 compliance.
Power Density: 5.3 Watts/Cubic inch.
Operating Temperature: 0 to +25/35/40°C
without derating. (various with output voltage)
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04%/°C typical.
Cooling: Free air convection.
Construction: Impact resistant plastic enclosure case.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The typical cord length is about 1 meter (3.3 ft.), AWG#18 cord for various load conditions.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
For the details of safety approval, please consult the factory.
-41-
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
AC PLUG
O/P VOLTAGE
O/P CURRENT
HEPG98-S120070-7L
DT7L
12Vdc
7.00A
HEPG98-S120070-8
DT8
12Vdc
7.00A
HEPG98-S150062-7L
DT7L
15Vdc
6.20A
HEPG98-S150062-8
DT8
15Vdc
6.20A
HEPG98-S190051-7L
DT7L
19Vdc
5.10A
HEPG98-S190051-8
DT8
19Vdc
5.10A
HEPG98-S240041-7L
DT7L
24Vdc
4.10A
HEPG98-S240041-8
DT8
24Vdc
4.10A
MECHANICAL DIMENSIONS: MM [INCHES]
-42-
WEIGHT: 400.0g (14.18 Oz.)