H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION (PFC) AC-DC INTERNAL OPEN FRAME SWITCHING POWER SUPPLIES 100 WATTS SINGLE OUTPUT HVP103 SERIES FEATURES: 5" X 3" X 1" COMPACT SIZE & HIGH POWER DENSITY ACCOMMODATE UNIVERSAL AC SOURCES MEET IEC 61000-3-2 HARMONIC CORRECTION (PFC) MEET UNIVERSAL SAFETY STANDARDS EMI MEET EN 55022 & FCC CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typical 90-264Vac with PFC. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Power: 100W continuous. Various with output voltage & under forced air cooling. Output Connector: V-M Molex 0.156” connector for <12A output. M-T Mini Terminal Block for ≥12A output. Line Regulation: Typical 0.1%. Load Regulation: Typical ± 1.0%. Noise & Ripple: Typical 1.0% peak to peak. OVP: Built-in. Adjustability: Available. Remote Sensing: Available. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. Input Connector: V-M connector & GND tag. Input Frequency: 47-63Hz. Inrush Current: Typical 26A at 230Vac. Input Current: Typical 1.0A at 115Vac, 0.5A at 230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet EN 55022 & FCC Class B. Hold-up Time: Typical 25mS at 115Vac & 230Vac. Power Factor & Harmonic Correction: Meet IEC 61000-3-2, PF typ. 0.97-0.99 at full load. Turn-on Delay/Rise Time: 2 Sec./5mS. Earth Leakage Current: Less than 0.5mA at 230Vac. GENERAL SPECIFICATION Efficiency: Typical 75-84%. various with output voltage. Switching Frequency: PWM 175K Hz. (PFC: 75K Hz.) Circuit Topology: Fixed Frequency Forward Circuit. Transient Response: 0.5mS following 25% load change. Safety Standard: IEC 60950-1/UL 60950-1 Class I. Power Density: 6.73 Watts / Cubic Inch. Operating Temperature: 0 to +50°C under 20 CFM forced air cooling for full load. Storage Temperature\Humidity: -20 to +85°C, 95% non-condensing. Temperature Coefficient: ±0.04% /°C. Cooling: At least 20CFM moving air is required to achieve full rating power, ≥+50°C in a confined area. Construction: L-bracket format. NOTE: (1)All measurement are at nominal input, full load and +25°C unless otherwise specifications. (2)Due to requests in market and advances in technology, specifications subject to change without notification. For the details of safety approval, please consult the factory. -73- OUTPUT VOLTAGE / CURRENT RATINGS CHART DEFINED OUTPUT VOLTAGE (Vdc) OUPUT VOLTAGE (Vdc) / CURRENT (A) 3.3-5.0Vdc/ 20.0-18.0A, 5.1-6.0Vdc/ 17.8-15.0A, 6.1-8.0Vdc/ 14.8-11.0A, 8.1-10.0Vdc/ 10.9-9.5A, 10.1-10.9Vdc/ 9.4-9.0A, 11.0-12.0Vdc/ 9.0-8.5A. 12.1-14.0Vdc/8.4-7.3A, 14.1-16.0Vdc/7.3-6.4A, 16.1-18.0Vdc/6.3-5.7A, 18.1-20.0Vdc/5.6-5.1A, 20.1-22.0Vdc/5.1-4.6A, 22.1-24.0Vdc/4.6-4.2A 3.3Vdc ≤ Any Voltage ≤12.0Vdc 12.0Vdc< Any Voltage ≤24.0Vdc SINGLE OUTPUT (Model No. for example) MODEL NO. HVP103-033200 HVP103-050180 HVP103-120085 HVP103-150068 HVP103-240042 MAIN O/P VO1 ★@# Min. 0.8A 0.6A 0.0A 0.5A 0.3A Typ. 20.0A 18.0A 8.5A 6.8A 4.2A Volt. 3.3V 5.0V 12.0V 15.0V 24.0V Peak 25.0A 25.0A 11.0A 8.5A 5.0A CONTINUOUS POWER 66W 90W 102W 103W 100W Symbol: "★" OVP built-in. "@" Adjustable. "#" Remote sensing. Remark: Peak output, less than 60sec. with 10% duty cycle. MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 319.0g (11.25 Oz.) INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT ASSIGNMENT LINE NEUTRAL GROUND CONNECTOR P1-1 P1-3 G & PIN # Mating connector: P1 & P2 Molex # 5195 or 41695 equivalent. P3 Molex # 5051 series or equivalent. VO1 P2-1,2(≧12A) P2-1,2,3(<12A) -74- SINGLE OUTPUT DC-COM P2-3,4(≧12A) P2-4,5,6(<12A) Remote Sensing P3-1(+S) P3-2(-S)