HITRON HIMP151

H HiTRON
2008/02/18
UNIVERSAL INPUT HARMONIC CORRECTION
AC-DC MEDICAL AND IEC APPLICATION OPEN FRAME SINGLE &
MULTI-OUTPUT 150 WATTS INTERNAL SWITCHING POWER
SUPPLIES HIMP151 SERIES
FEATURES:
„ 5” X 3”* X 1.38” COMPACT SIZE
„ ACCOMMODATE UNIVERSAL AC SOURCES
„ MEET IEC 61000-3-2 HARMONIC
CORRECTION
„ MEET UNIVERSAL SAFETY STANDARDS
„ EMI MEET CISPR EN 55022/EN 55011 & FCC
CLASS B CONDUCTED
„ CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: V-M connector.
Input Frequency: 47-63Hz.
Inrush Current: 9.3-11.3Arms @230Vac.
Input Current: Typ. 2.2A @115Vac, 0.9A @230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR EN 55022 & FCC Class B conducted.
Meet CISPR EN 55011 & FCC Class B conducted.
Hold-up Time: Typ. 90mS @115Vac & 230Vac.
Power Factor & Harmonic Correction:
Meet IEC 61000-3-2, PF typ. 0.99 @ full load.
Over Temperature Protection: Installed.
Leakage Current: 0.40-0.50mA @230Vac touch current.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: V-M connector.
Output Wattage: Max. 150 watts.
Line Regulation: Typ. 1.0%.
Load Regulation: Single O/P VO1 ±3.0%.
Dual O/P VO1 ±3.0% VO2 ±1.0%
Triple O/P VO1 ± 3.0% (± 8% for 3.3V), VO2/VO3 ±3.0%.
Quad O/P VO1/VO2/VO3/VO4 ±3.0%
Noise & Ripple: Typ. 1.0-2.0% peak to peak.
OVP: Built-in at VO1 and VO2.
Adjustability: Available at VO1 and VO2.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 76-80% various with output.
Switching Frequency: 68K Hz.
Circuit Topology: Single Fixed frequency forward circuit.
Dual/Triple/Quad: Fixed freq. flyback circuit.
Transient Response: Output voltage returns in less than
14.8-25.2mS following a 25% load change.
Safety Standard: IEC 60950-1 Class I for IEC use.
IEC 60601-1 Class I for Medical use.
Operating Temperature: 0 to +50°C under 30 CFM
forced air cooling for full load.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: Requested 30 CFM forced air flow for full load.
Construction: U-bracket format.
Power Density: 6.52-7.24 Watts / Cubic Inch .
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
OUTPUT VOLTAGE / CURRENT RATINGS CHART
DUAL OUTPUT (Under forced air cooling)
SINGLE OUTPUT (Under air cooling)
MODEL NO.
MAIN VO1 ★@
Typ. Volt. Max.
HIMP151-S050270 27A
HIMP151-S120125 12.5A
HIMP151-S150100 10.0A
HIMP151-S240063 6.3A
5V
12V
15V
24V
2008/02/18
MODEL NO.
30A
12.5A
10.0A
6.3A
HIMP151-D050I
HIMP151-D050M
HIMP151-D120I
HIMP151-D150K
MAIN VO1 ★@
Typ.
Volt. Max.
15.00A
15.0A
6.25A
5.0A
+5V
+5V
+12V
+15V
15.00A
15.0A
6.25A
5.00A
AUX. VO2 ★@
Typ.
Max.
Volt.
6.00A
3.00A
6.25A
5.00A
+12V
+24V
+12V
+15V
6.00A
3.00A
6.25A
5.00A
TRIPLE OUTPUT (Under forced air cooling)
MODEL NO.
HIMP151-T033EI
HIMP151-T050II
HIMP151-T050KK
MAIN VO1 ★@
Typ. Volt. Max.
AUX. VO2 ★@
Typ.
Max.
Volt.
AUX. VO3 ●
Typ.
Volt. Max.
18A
15A
15A
13.5A
5.5A
4.5A
0.8A
0.8A
0.5A
20A
15A
15A
+3.3V
+5.0V
+5.0V
+5V
+12V
+15V
15A
5.5A
4.5A
+12V
+12V
+15V
0.8A
0.8A
0.5A
QUAD OUTPUT (Under forced air cooling)
MODEL NO.
MAIN VO1 ★@
Typ. Volt. Max.
AUX. VO2 ★@
Typ.
Max.
Volt.
AUX. VO3 ●
Typ.
Volt. Max.
15A
15A
4A
4A
0.8A
HIMP151-Q050KKE
+5V
+15V
Symbol: "★" OVP built-in. "@" Adjustable. "●" Post –Regulated
Remark: Please refer to the derating chart depending on ambient temperature and fan cooling.
-15V
0.8A
AUX. VO4 ●
Typ.
Max.
Volt.
0.5A
-5V
0.5A
WEIGHT: 385.0g (13.4 Oz.)
MECHANICAL DIMENSIONS: MM [INCHES]
SINGLE
DUAL/TRIPLE/QUAD
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ASSIGNMENT
AC AC- AC-L
N
G
P1- P1- P1CNTR & PIN #
L
N
G
SINGLE O/P
VO1
P2-1,2,
3,4,5,6
DCCOM
DUAL O/P
VO1
VO2
P2-7,8,9 P2-1,2,3,
P2-9,10
10,11,12
4
Mating connector: Moles 5195 or 5239 series.
TRIPLE O/P
DCCOM
VO1
P2-5,
6,7,8
P2-1,2,
3,4
VO2
P2-9,10
QUAD O/P
VO3
DCCOM
VO1
VO2
VO3
+VO4
DC COM
P2-11
P2-5,
6,7,8
P2-1,
2,3,4
P2-9,10
P2-11
P2-12
P2-5,6,
7,8
DERATING CHART
2008/2/18
HIMP151-S050270
Forced air cooling- 5CFM
Forced air cooling- 20CFM
Forced air cooling- 30CFM
Power derating
Power derating
Power derating
100
90
80
70
60
% 50
40
30
20
10
0
100
90
80
70
60
% 50
40
30
20
10
0
100
90
80
70
60
% 50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
0
10
20
30
40
deg C
50
60
70
80
90
100
0
HIMP151-D050I
Forced air cooling- 5CFM
100
90
80
70
60
% 50
40
30
20
10
0
20
30
40
50
60
70
80
0
10
20
30
40
50
60
70
80
90
40
50
60
70
80
90 100
100
90
80
70
60
% 50
40
30
20
10
0
30
40
50
deg C
60
70
80
90
100
20
30
40
50
60
70
80
90
100
deg C
Power derating
Power derating
100
90
80
70
60
% 50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90 100
deg C
Forced air cooling- 20CFM
Forced air cooling- 26CFM
Power derating
Power derating
100
90
80
70
60
% 50
40
30
20
10
0
100
90
80
70
60
% 50
40
30
20
10
0
20
90
Forced air cooling- 30CFM
Power derating
10
10
deg C
HIMP151-Q050KKE
Forced air cooling- 5CFM
80
Forced air cooling- 20CFM
deg C
0
0
100
100
90
80
70
60
% 50
40
30
20
10
0
30
70
100
90
80
70
60
% 50
40
30
20
10
0
deg C
100
90
80
70
60
% 50
40
30
20
10
0
60
Power derating
Power derating
20
50
Power derating
90
HIMP151-T033EI
Forced air cooling- 5CFM
10
40
Forced air cooling- 23CFM
deg C
0
30
deg C
100
90
80
70
60
% 50
40
30
20
10
0
10
20
Forced air cooling- 20CFM
Power derating
0
10
deg C
0
10
20
30
40
50
deg C
60
70
80
90 100
0
10
20
30
40
50
deg C
60
70
80
90 100