H HiTRON 2008/02/18 UNIVERSAL INPUT HARMONIC CORRECTION AC-DC MEDICAL AND IEC APPLICATION OPEN FRAME SINGLE & MULTI-OUTPUT 150 WATTS INTERNAL SWITCHING POWER SUPPLIES HIMP151 SERIES FEATURES: 5” X 3”* X 1.38” COMPACT SIZE ACCOMMODATE UNIVERSAL AC SOURCES MEET IEC 61000-3-2 HARMONIC CORRECTION MEET UNIVERSAL SAFETY STANDARDS EMI MEET CISPR EN 55022/EN 55011 & FCC CLASS B CONDUCTED CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typ. 90-264Vac with PFC. Input Connector: V-M connector. Input Frequency: 47-63Hz. Inrush Current: 9.3-11.3Arms @230Vac. Input Current: Typ. 2.2A @115Vac, 0.9A @230Vac. Dielectric Withstand: Meet IEC 60950-1. EMI: Meet CISPR EN 55022 & FCC Class B conducted. Meet CISPR EN 55011 & FCC Class B conducted. Hold-up Time: Typ. 90mS @115Vac & 230Vac. Power Factor & Harmonic Correction: Meet IEC 61000-3-2, PF typ. 0.99 @ full load. Over Temperature Protection: Installed. Leakage Current: 0.40-0.50mA @230Vac touch current. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: V-M connector. Output Wattage: Max. 150 watts. Line Regulation: Typ. 1.0%. Load Regulation: Single O/P VO1 ±3.0%. Dual O/P VO1 ±3.0% VO2 ±1.0% Triple O/P VO1 ± 3.0% (± 8% for 3.3V), VO2/VO3 ±3.0%. Quad O/P VO1/VO2/VO3/VO4 ±3.0% Noise & Ripple: Typ. 1.0-2.0% peak to peak. OVP: Built-in at VO1 and VO2. Adjustability: Available at VO1 and VO2. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 125-150% rating output wattage. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typ. 76-80% various with output. Switching Frequency: 68K Hz. Circuit Topology: Single Fixed frequency forward circuit. Dual/Triple/Quad: Fixed freq. flyback circuit. Transient Response: Output voltage returns in less than 14.8-25.2mS following a 25% load change. Safety Standard: IEC 60950-1 Class I for IEC use. IEC 60601-1 Class I for Medical use. Operating Temperature: 0 to +50°C under 30 CFM forced air cooling for full load. Storage Temperature: -20 to +85°C. Temperature Coefficient: Typ. 0.04% /°C. Cooling: Requested 30 CFM forced air flow for full load. Construction: U-bracket format. Power Density: 6.52-7.24 Watts / Cubic Inch . Note: Due to requests in market and advances in technology, specifications subject to change without notification. For the details of safety approval, please consult the factory. OUTPUT VOLTAGE / CURRENT RATINGS CHART DUAL OUTPUT (Under forced air cooling) SINGLE OUTPUT (Under air cooling) MODEL NO. MAIN VO1 ★@ Typ. Volt. Max. HIMP151-S050270 27A HIMP151-S120125 12.5A HIMP151-S150100 10.0A HIMP151-S240063 6.3A 5V 12V 15V 24V 2008/02/18 MODEL NO. 30A 12.5A 10.0A 6.3A HIMP151-D050I HIMP151-D050M HIMP151-D120I HIMP151-D150K MAIN VO1 ★@ Typ. Volt. Max. 15.00A 15.0A 6.25A 5.0A +5V +5V +12V +15V 15.00A 15.0A 6.25A 5.00A AUX. VO2 ★@ Typ. Max. Volt. 6.00A 3.00A 6.25A 5.00A +12V +24V +12V +15V 6.00A 3.00A 6.25A 5.00A TRIPLE OUTPUT (Under forced air cooling) MODEL NO. HIMP151-T033EI HIMP151-T050II HIMP151-T050KK MAIN VO1 ★@ Typ. Volt. Max. AUX. VO2 ★@ Typ. Max. Volt. AUX. VO3 ● Typ. Volt. Max. 18A 15A 15A 13.5A 5.5A 4.5A 0.8A 0.8A 0.5A 20A 15A 15A +3.3V +5.0V +5.0V +5V +12V +15V 15A 5.5A 4.5A +12V +12V +15V 0.8A 0.8A 0.5A QUAD OUTPUT (Under forced air cooling) MODEL NO. MAIN VO1 ★@ Typ. Volt. Max. AUX. VO2 ★@ Typ. Max. Volt. AUX. VO3 ● Typ. Volt. Max. 15A 15A 4A 4A 0.8A HIMP151-Q050KKE +5V +15V Symbol: "★" OVP built-in. "@" Adjustable. "●" Post –Regulated Remark: Please refer to the derating chart depending on ambient temperature and fan cooling. -15V 0.8A AUX. VO4 ● Typ. Max. Volt. 0.5A -5V 0.5A WEIGHT: 385.0g (13.4 Oz.) MECHANICAL DIMENSIONS: MM [INCHES] SINGLE DUAL/TRIPLE/QUAD INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT ASSIGNMENT AC AC- AC-L N G P1- P1- P1CNTR & PIN # L N G SINGLE O/P VO1 P2-1,2, 3,4,5,6 DCCOM DUAL O/P VO1 VO2 P2-7,8,9 P2-1,2,3, P2-9,10 10,11,12 4 Mating connector: Moles 5195 or 5239 series. TRIPLE O/P DCCOM VO1 P2-5, 6,7,8 P2-1,2, 3,4 VO2 P2-9,10 QUAD O/P VO3 DCCOM VO1 VO2 VO3 +VO4 DC COM P2-11 P2-5, 6,7,8 P2-1, 2,3,4 P2-9,10 P2-11 P2-12 P2-5,6, 7,8 DERATING CHART 2008/2/18 HIMP151-S050270 Forced air cooling- 5CFM Forced air cooling- 20CFM Forced air cooling- 30CFM Power derating Power derating Power derating 100 90 80 70 60 % 50 40 30 20 10 0 100 90 80 70 60 % 50 40 30 20 10 0 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 deg C 50 60 70 80 90 100 0 HIMP151-D050I Forced air cooling- 5CFM 100 90 80 70 60 % 50 40 30 20 10 0 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 90 40 50 60 70 80 90 100 100 90 80 70 60 % 50 40 30 20 10 0 30 40 50 deg C 60 70 80 90 100 20 30 40 50 60 70 80 90 100 deg C Power derating Power derating 100 90 80 70 60 % 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 deg C Forced air cooling- 20CFM Forced air cooling- 26CFM Power derating Power derating 100 90 80 70 60 % 50 40 30 20 10 0 100 90 80 70 60 % 50 40 30 20 10 0 20 90 Forced air cooling- 30CFM Power derating 10 10 deg C HIMP151-Q050KKE Forced air cooling- 5CFM 80 Forced air cooling- 20CFM deg C 0 0 100 100 90 80 70 60 % 50 40 30 20 10 0 30 70 100 90 80 70 60 % 50 40 30 20 10 0 deg C 100 90 80 70 60 % 50 40 30 20 10 0 60 Power derating Power derating 20 50 Power derating 90 HIMP151-T033EI Forced air cooling- 5CFM 10 40 Forced air cooling- 23CFM deg C 0 30 deg C 100 90 80 70 60 % 50 40 30 20 10 0 10 20 Forced air cooling- 20CFM Power derating 0 10 deg C 0 10 20 30 40 50 deg C 60 70 80 90 100 0 10 20 30 40 50 deg C 60 70 80 90 100