TOTAL-POWER HVP101

H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC
OPEN FRAME SINGLE & MULTIPLE OUTPUT 100 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP101 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
PCB VERSION FORMAT
MEET IEC1000-3-2 HARMONIC CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: V-M connector & GND tag.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 29A@230Vac.
Input Current: Typ. 1.3A @115Vac, 0.65A @230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Meet CISPR EN55022 B & FCC Class B.
Hold-up Time: Typ. 18-25mS @ 115Vac & 230Vac.
Power Factor & Harmonic Correction:
Meet IEC1000-3-2, PF typ. 0.97-0.99 @ full load.
Power OK: Installed in VO1 & VO2.
Over Temperature Protection (OTP): By NTC at quad
output only.
Earth Leakage: Less than 0.75mA @230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: V-M connector.
Output Wattage: Typ. 100 Watts.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1-2%.
Aux. VO2 typ. ±1-2% (Magnetic Amp.).
Aux. VO3 typ. ±1-2% (Magnetic Amp.).
Aux. VO4 typ. ±2-3% (P.R.).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1 & Aux.VO2 & VO3 (latch).
Remote Sensing: Available at VO1 & VO2.
Adjustability: Available at VO1,VO2 & VO3.
Over Current Protection: Built-in at all output.
Overload Protection (OLP): Fully protected against
output overload and short circuit at any output.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 75-80%.
Switching Frequency: PFC ckt. 75K Hz.
PWM ckt. 170-180K Hz.
Circuit Topology: Fixed frequency forward circuit.
Transient Response: Output voltage returns in
less than 0.3mS following
a 25% load change.
Safety Standard: IEC950/UL1950 Class I.
Operating Temperature: 0 to +50°C under forced air
flow for full load.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04% /°C.
Cooling: At least 30 cfm direct forward air flow is
required to achieve full rating power.
Construction: PCB format.
Power Density: 5.6 Watts / Cubic Inch.
-49-
In application
OUTPUT VOLTAGE / CURRENT RATINGS CHART
DUAL OUTPUT (Under forced air flow)
SINGLE OUTPUT (Under forced air flow)
MODEL NO.
HVP101-S033200
HVP101-S050160
HVP101-S120085
HVP101-S150068
HVP101-S240042
HVP101-S280036
HVP101-S360028
HVP101-S480021
MAIN VO1 ★@#
Typ.
Peak
Volt.
20.0A
3.3V 25.0A
16.0A
5.0V 20.0A
8.5A 12.0V
9.0A
6.8A 15.0V
7.0A
4.2A 24.0V
6.0A
3.6A 28.0V
5.0A
2.8A 36.0V
4.0A
2.1A 48.0V
3.0A
MODEL NO.
HVP101-D050E
HVP101-D050I
HVP101-D050K
HVP101-D050D
HVP101-D033I
HVP101-D033K
MAIN VO1
Typ.
12.0A
12.0A
12.0A
12.0A
15.0A
15.0A
AUX. VO2 ▲#
Typ.
Volt.
6.0A
+5.0V
4.0A
+12.0V
3.0A
+15.0V
8.0A
+3.3V
4.0A
+12.0V
3.0A
+15.0V
★@#
Volt.
+5.0V
+5.0V
+5.0V
+5.0V
+3.3V
+3.3V
QUAD OUTPUT (Under forced air flow)
MODEL NO.
HVP101-Q050DII
HVP101-Q050DIE
HVP101-Q050MII
HVP101-Q050KIE
HVP101-Q050KII
MAIN VO1 ★@#
Typ.
Volt
12.0A
+5.0V
12.0A
+5.0V
10.0A
+5.0V
10.0A
+5.0V
8.0A
+5.0V
AUX. VO2
Typ.
6.0A
7.0A
1.5A
2.5A
2.5A
★@▲#
Volt
+ 3.3V
+ 3.3V
+24.0V
+15.0V
+15.0V
AUX. VO3
Typ.
1.5A
1.5A
1.5A
1.5A
2.0A
AUX. VO4 ●
Typ.
Volt
0.5A
-12V
0.5A
- 5V
0.2A
-12V
0.4A
- 5V
0.2A
-12V
★@▲
Volt
+12V
+12V
+12V
+12V
+12V
Symbol: "★" OVP built-in. "@" Adjustable. "#" Remote sense. "●" Installed with Post Regulator. "▲" Installed with magnetic amplifier.
Remark: Peak output, less than 60 Sec. with 10% duty cycle.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 368.0g(12.97 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS
AC INPUT
ASSIGNMENT
CONNECTOR
& PIN #
L
N
P1-3 P1-1
SINGLE OUTPUT
GND
VO1
Tab
P2-6,7,8,
9,10,11
DC
COM
P2-1,2,
3,4,5
DUAL OUTPUT
+VO1#
P.OK
VO1
VO2
P2-13
P2-14
P2-9,
10,11
P2-6,
7,8
DC
DC
+VO1 # +VO2 # P.OK VO1
VO2
COM
COM
P2-1,2,
P2-1,2, P2-5,6
P2-13
P2-12 P2-14
P2-9,10
3,4
3,4
7,8
Mating connector: Molex 5195 or 5239 series.
-50-
QUAD OUTPUT
VO3
VO4
P2-11 P2-12
VO1+ #
VO2+ #
P3-3
P3-4
VO1,2- # P. OK
P3-1
P3-2