Preset counters electromechanic 1 preset, subtracting Display 5-digits, manual reset button FS304, FS314, FS324 Features –– Preset counter with one preset –– Subtracting –– Display 5-digits –– With reset button FS304 - Socket box 24/110 VAC ±10 % (50/60 Hz) 230 VAC +6/-10 % (50/60 Hz) 24 VDC ±10 % Ripple residue <48 % Nominal frequency 50 / 60 Hz Pulse ratio 1:1 Service life 100 million impulses Preset 1 preset Output contact Change-over contact by microswitch, one-pole Switching capacity 100 VA / 30 W Limit switch service life 1 million switching cycles Spark extinguisher Recommended for inductive load Standard DIN EN 61010‑1 Protection class II Overvoltage category II Pollution degree 2 Emitted interference DIN EN 61000-6-4 Interference immunity DIN EN 61000-6-2 Approval CE conform FS324 - Front panel with spring clip 1 www.baumerivo.com 2/12/2008 FS314 - Front panel with screw mount Voltage supply Subject to modification in technic and design. Errors and omissions excepted. Technical data - electrical ratings Preset counters electromechanic 1 preset, subtracting Display 5-digits, manual reset button FS304, FS314, FS324 Technical data - mechanical design Display White numbers on black Number of digits 5-digits Digit height 4.5 mm Count mode 1 impulse = 1 count Step-by-step switching Subtracting in 2 half steps Measuring range 99 999 Reset Manual by reset button Operating temperature 0...+60 °C Storing temperature -20...+70 °C Relative humidity 80 % non-condensing Protection DIN EN 60529 IP 41 E-connection Soldering pins (flat) Weight approx. 150 g Material Housing: Noryl PPO, black Connection diagram 3 + (-) (+) Voltage Socket box Mounting Socket box Dimensions W x H x L 50 x 50 x 85.9 mm Cutout dimensions 50 x 50 mm Installation depth 85.9 mm 21 20 22 End contact Trigger level FS304 Housing type 4 Count Voltage DC Voltage AC Power 2.2 W 2.4 VA Min. pulse duration 25 ms 50 ms Min. pulse interval 25 ms 50 ms Switch on time (at 25 °C) 100 % 100 % Electronic reset Voltage DC Voltage AC Power 22 W 25 VA Min. pulse duration 250 ms 250 ms Min. pulse interval 9x pulse duration 9x pulse duration Switch on time (at 25 °C) 10 % max. 1 min 10 % max. 1 min FS314 Front panel with 2 screws Dimensions W x H x L 60 x 75 x 61 mm Cutout dimensions 51 x 51 mm Installation depth 77.5 mm Accessories Front panels for FS304 Z 100.02A Front frames for FS304 FS324 Housing type Built-in housing Mounting Front panel with spring clips Dimensions W x H x L 53.2 x 53.2 x 61 mm Cutout dimensions 51 x 51 mm Installation depth 77.5 mm Front panel with transparent protective cover, for socket box 50 x 50 mm 2 Z 102.01A Front frame with knob lock provided on transparent cover Z 102.02A Front frame with cylinder lock provided on transparent cover Z 107.02A Front frame, insertion cutout 50 x 50 mm www.baumerivo.com Subject to modification in technic and design. Errors and omissions excepted. Built-in housing Mounting 2/12/2008 Housing type Preset counters electromechanic 1 preset, subtracting Display 5-digits, manual reset button FS304, FS314, FS324 Part number Socket box Front panel with screw mount FS304. 550A B FS314. 550A B Display B 5-digits 99999 A3 A5 A8 A9 Display B 5-digits 99999 Voltage 24 VDC 24 VAC 110 VAC 230 VAC A3 A5 A8 A9 Reset 550A With reset button Voltage 24 VDC 24 VAC 110 VAC 230 VAC Reset 550A With reset button Front panel with spring clips mount FS324. 550A B Display B 5-digits 99999 A3 A5 A8 A9 Voltage 24 VDC 24 VAC 110 VAC 230 VAC 3 www.baumerivo.com 2/12/2008 Subject to modification in technic and design. Errors and omissions excepted. Reset 550A With reset button Preset counters electromechanic 1 preset, subtracting Display 5-digits, manual reset button FS304, FS314, FS324 Dimensions FS304 socket box FS314 front panel with 2 screws 30 8 75 63 50 50 6 8 12.5 50 18.5 67.4 10 5 50 60 16.5 61 3 10 FS324 front panel with spring clip 6 16.5 61 3 10 Subject to modification in technic and design. Errors and omissions excepted. 50 53.2 4 www.baumerivo.com 2/12/2008 1.6 50 53.2 1.6 8