Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button FE504, FE514, FE524 Features –– Preset counter with one preset –– Adding –– Display 6-digits –– With reset button FE504 - Socket box 24/110 VAC ±10 % (50/60 Hz) 230 VAC +6/-10 % (50/60 Hz) 24 VDC ±10 % Ripple residue <48 % Nominal frequency 50 / 60 Hz Pulse ratio 1:1 Service life VDC - 100 million impulses VAC - 50 million impulses Preset 1 preset Output contact Change-over contact by microswitch, one-pole Switching capacity 100 VA / 30 W Limit switch service life 1 million switching cycles Spark extinguisher Recommended for inductive load Standard DIN EN 61010‑1 Protection class II Overvoltage category II Pollution degree 2 Emitted interference DIN EN 61000-6-4 Interference immunity DIN EN 61000-6-2 Approvals CE conform, UL/cUL FE524 - Front panel with spring clip 1 www.baumerivo.com 2/12/2008 FE514 - Front panel with screw mount Voltage supply Subject to modification in technic and design. Errors and omissions excepted. Technical data - electrical ratings Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button FE504, FE514, FE524 Technical data - mechanical design 6-digits Digit height 4.5 mm Count mode 1 impulse = 1 count Step-by-step switching Adding in 2 half steps Measuring range 999 999 Reset Manual by reset button Operating temperature 0...+60 °C Storing temperature -20...+70 °C Relative humidity 80 % non-condensing Protection DIN EN 60529 IP 41 E-connection Soldering pins (flat) Weight approx. Material 3 4 + (-) (+) Voltage 21 20 22 End contact Trigger level Max. counting speed 10 pulses/s Voltage 24/110 VAC ±10 % 230 VAC +6/-10 % 160 g Power 3 VA Housing: Noryl PPO, black Min. pulse duration 50 ms Min. pulse interval 50 ms 100 % FE504 Housing type Socket box Switch on time (at 25 °C) Mounting Socket box Dimensions W x H x L 50 x 50 x 88.1 mm Max. counting speed 20 pulses/s Cutout dimensions 50 x 50 mm Installation depth 88.3 mm FE514 Voltage 24 VDC ±10 % Power 2W Min. pulse duration 25 ms Min. pulse interval 25 ms Switch on time (at 25 °C) 100 % Housing type Built-in housing Mounting Front panel with 2 screws Dimensions W x H x L 60 x 75 x 61.3 mm Accessories Cutout dimensions 51 x 51 mm Installation depth 79.7 mm Front panels for FE504 Z 100.02A FE524 Front panel with transparent protective cover, for socket box 50 x 50 mm Housing type Built-in housing Front frames for FE504 Mounting Front panel with spring clips Z 102.01A Dimensions W x H x L 53.2 x 53.2 x 61 mm Front frame with knob lock provided on transparent cover Cutout dimensions 51 x 51 mm Z 102.02A Installation depth 79.7 mm Front frame with cylinder lock provided on transparent cover Z 107.02A Front frame, insertion cutout 50 x 50 mm 2 www.baumerivo.com Subject to modification in technic and design. Errors and omissions excepted. White numbers on black Number of digits 2/12/2008 Display Connection diagram Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button FE504, FE514, FE524 Part number Socket box Front panel with screw mount FE504. 650B C FE514. 650A C Display C 6-digits 999 999 B3 B5 B8 B9 Display C 6-digits 999 999 Voltage 24 VDC 24 VAC 110 VAC 230 VAC B3 B5 B8 B9 Reset 650B With reset button Voltage 24 VDC 24 VAC 110 VAC 230 VAC Reset 650A With reset button Front panel with spring clips mount FE524. 650B C Display C 6-digits 999 999 B3 B5 B8 B9 Voltage 24 VDC 24 VAC 110 VAC 230 VAC 3 www.baumerivo.com 2/12/2008 Subject to modification in technic and design. Errors and omissions excepted. Reset 650B With reset button Preset counters electromechanic 1 preset, adding Display 6-digits, manual reset button FE504, FE514, FE524 Dimensions FE514 front panel with 2 screws 6.5 30 20.7 63 75 50.3 49.6 12.35 6.5 49.6 6 FE504 socket box 67.4 4.85 50.3 60 61.3 2.7 FE524 front panel with spring clip 1.45 6 18.4 61.3 2.7 Subject to modification in technic and design. Errors and omissions excepted. 50.3 4 www.baumerivo.com 2/12/2008 53.2 1.45 6.5 50.3 53.2