TLYE260A TOSHIBA LED Lamp InGaAℓP Yellow Light Emission TLYE260A Panel Circuit Indicator Unit in mm · 3.0 mm diameter · InGaAℓP yellow LED · All plastic mold type. · Colorless clear lens · Low drive current, high intensity yellow light emission · All plastic molded lens, provides an excellent on−off contrast ratio. · Fast response time, capable of pulse operation. · High power luminous intensity · Wide radiation pattern. · Applications: Suitable for backlighting. Recommended forward current: IF = 15~20 mA (DC) Maximum Ratings (Ta = 25°C) Characteristic Symbol Rating Unit Forward current (DC) IF 50 mA Reverse voltage VR 4 V Power dissipation PD 125 mW Operating temperature range Topr -30~85 °C TOSHIBA Storage temperature range Tstg -40~120 °C Weight: 0.12 g 1 JEDEC ― EIAJ ― 4−3L1 2002-09-25 TLYE260A Electrical And Optical Characteristics (Ta = 25°C) Characteristic Symbol Test Condition Min Typ. Max Unit Forward voltage VF IF = 20mA ¾ 2.1 2.5 V Reverse current IR VR = 4V ¾ ¾ 50 µA IV IF = 20mA 15.3 40 ¾ 15.3 ¾ 73.6 Peak emission wavelength λP IF = 20mA ¾ 590 ¾ nm Spectral line half width ∆λ IF = 20mA ¾ 13 ¾ nm Dominant wavelength λd IF = 20mA ¾ 587 ¾ nm Luminous intensity TLYE260A TLYE260A (KL) (Note) mcd (Note): Lamps are classified into the following ranks according to their luminous intensity. Measurement tolerance for each limit is ±15%. K: 18-36 mcd, L: 32-64mcd, M: 56-112mcd. Precaution · Please be careful of the followings Soldering temperature: 260°C max Soldering time: 3s max (Soldering portion of lead: Up to 2mm from the body of the device) · If the lead is formed, the lead should be formed up to 5mm from the body of the device without forming stress to the resin. Soldering should be performed after lead forming. · This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure that it will not be affected by this IR light. 2 2002-09-25 TLYE260A IF – VF IV – IF 50 500 (mcd) IV 10 5 3 1 1.7 1.8 1.9 2.0 2.1 Forward voltage 2.2 VF 2.3 Ta = 25 °C 300 100 Luminous intensity Forward current IF (mA) Ta = 25 °C 30 50 30 10 5 3 2 2.4 1 5 10 30 Forward current 50 IF 100 300 500 (mA) Relative Luminous Intensity Wavelength IV – Tc 1.0 3 IF = 20 mA Ta = 25 °C Relative luminous intensity IV 1 0.5 0.3 0.1 −20 0 20 40 Case temperature Tc 60 0.8 0.6 0.4 0.2 0 540 80 560 580 600 Wavelength λ (°C) Radiation Pattern 620 640 660 (nm) IF – Ta 80 Ta = 25 °C 20° 10° 0° 10° Allowable forward current IF (mA) Relative luminous intensity 3 (V) 20° 30° 30° 40° 40° 50° 50° 60° 60° 70° 70° 80° 90° 1 0.8 0.6 0.4 0.2 60 40 20 0 0 0 20 40 60 80 100 Ambient temperature Ta (°C) 3 2002-09-25 TLYE260A RESTRICTIONS ON PRODUCT USE 000707EAC · TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. · The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with domestic garbage. · The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. · The information contained herein is subject to change without notice. 4 2002-09-25