TOTAL-POWER T-40

TOTAL POWER INT'L
T- 4 0
40W Triple Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 40KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
T-40A
T-40C
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
RATED CURRENT
3A
2A
0.5A
3A
2A
0.5A
3A
1.5A
0.5A
CURRENT RANGE
0.6 ~ 5A
0.2 ~ 3A
0.1 ~ 1A
0.6 ~ 5A
0.2 ~ 3A
0.1 ~ 1A
0.6 ~ 5A
0.2 ~ 2A
0.1 ~ 1A
RATED POWER
41.5W
120mVp-p
120mVp-p
45W
120mVp-p
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
6.0%
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
LOAD REGULATION
INPUT
T-40B
DC VOLTAGE
100mVp-p
100mVp-p
8.0%
8.0%
2.0%
6.0%
6.0%
1.0%
0.5%
1.0%
1.0%
0.5%
1.0%
1.0%
0.5%
4.0%
6.0%
0.5%
4.0%
6.0%
0.5%
4.0%
4.0%
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
72%/115VAC
AC CURRENT
INRUSH CURRENT(max.)
1.2A/115VAC
0.7A/230VAC
COLD START 20A/115VAC
40A/230VAC
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
100mVp-p
CH1 : 4.75 ~ 5.5V
1.0%
VOLTAGE RANGE
OVER LOAD
120mVp-p
0.5%
800ms, 50ms, 60ms/230VAC
PROTECTION
120mVp-p
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
SETUP, RISE, HOLD TIME
LEAKAGE CURRENT
45W
1.6s, 50ms,16ms/115VAC at full load
120 ~ 370VDC
72%/115VAC
72%/115VAC
<3.5mA / 240VAC
105 ~ 150%/115VAC of rate load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
CSA 950, (UL1950, IEC950, TUV EN60950) Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
OTHERS
NOTE
HARMONIC CURRENT
EMS IMMUNITY
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
MTBF
305.6K hrs min. MIL-HDBK-217F (25
129*98*38mm (L*W*H)
0.45Kg; 30pcs/13.5Kg/0.86CUFT
DIMENSION
PACKING
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
T- 4 0
40W Triple Output Switching Power Supply
Mechanical Specification
Case No. 903
4.5
series
Unit:mm
31
3 .5
7
122.5
1
9.5
2
8 5 .5
33
4
8.2
5
9 7 .7 5
2-
M
3
3
6
7
3 .5
73.5
4.5
129
6.5
32
3
9
3 7 .5
3 .5
3 .5
3 -M
18
1 8 .5
9
9 .5
120
77
Terminal Pin. No Assignment
Assignment
AC/L
AC/N
FG
Pin No.
1
2
3
Pin No.
4
5
6
Assignment
DC OUTPUT -V
DC OUTPUT +V2
DC OUTPUT COM
Pin No.
7
Assignment
DC OUTPUT +V1
Static Characteristics (B)
Output Derating
Ta=25
100
OUTPUT VOLTAGE (V)
-12V
80
60
LOAD (%)
300
5.2
40
20
12
250
5.0
+5V
+12V
11
4.8
10
4.6
150
9
4.4
100
8
4.2
7
4.0
+12V
+5V
0
10
20
30
40
AMBIENT TEMPERATURE (
50
45
)
60
55
(VERTICAL)
(HORIZONTAL)
50
25
-12V
-10
200
60
80
100
120
140
160
180
200
INPUT VOLTAGE (V) 60Hz
220
240
260
OUTPUT RIPPLE (mVp-p)
13