TOTAL POWER INT'L T- 4 0 40W Triple Output Switching Power Supply series Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 40KHz 2 years warranty SPECIFICATION MODEL OUTPUT T-40A T-40C 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 3A 2A 0.5A 3A 2A 0.5A 3A 1.5A 0.5A CURRENT RANGE 0.6 ~ 5A 0.2 ~ 3A 0.1 ~ 1A 0.6 ~ 5A 0.2 ~ 3A 0.1 ~ 1A 0.6 ~ 5A 0.2 ~ 2A 0.1 ~ 1A RATED POWER 41.5W 120mVp-p 120mVp-p 45W 120mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V 6.0% VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION INPUT T-40B DC VOLTAGE 100mVp-p 100mVp-p 8.0% 8.0% 2.0% 6.0% 6.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 4.0% 6.0% 0.5% 4.0% 6.0% 0.5% 4.0% 4.0% 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 72%/115VAC AC CURRENT INRUSH CURRENT(max.) 1.2A/115VAC 0.7A/230VAC COLD START 20A/115VAC 40A/230VAC OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 100mVp-p CH1 : 4.75 ~ 5.5V 1.0% VOLTAGE RANGE OVER LOAD 120mVp-p 0.5% 800ms, 50ms, 60ms/230VAC PROTECTION 120mVp-p CH1 : 4.75 ~ 5.5V 2.0% 6.0% SETUP, RISE, HOLD TIME LEAKAGE CURRENT 45W 1.6s, 50ms,16ms/115VAC at full load 120 ~ 370VDC 72%/115VAC 72%/115VAC <3.5mA / 240VAC 105 ~ 150%/115VAC of rate load Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes CSA 950, (UL1950, IEC950, TUV EN60950) Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) OTHERS NOTE HARMONIC CURRENT EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A MTBF 305.6K hrs min. MIL-HDBK-217F (25 129*98*38mm (L*W*H) 0.45Kg; 30pcs/13.5Kg/0.86CUFT DIMENSION PACKING ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. T- 4 0 40W Triple Output Switching Power Supply Mechanical Specification Case No. 903 4.5 series Unit:mm 31 3 .5 7 122.5 1 9.5 2 8 5 .5 33 4 8.2 5 9 7 .7 5 2- M 3 3 6 7 3 .5 73.5 4.5 129 6.5 32 3 9 3 7 .5 3 .5 3 .5 3 -M 18 1 8 .5 9 9 .5 120 77 Terminal Pin. No Assignment Assignment AC/L AC/N FG Pin No. 1 2 3 Pin No. 4 5 6 Assignment DC OUTPUT -V DC OUTPUT +V2 DC OUTPUT COM Pin No. 7 Assignment DC OUTPUT +V1 Static Characteristics (B) Output Derating Ta=25 100 OUTPUT VOLTAGE (V) -12V 80 60 LOAD (%) 300 5.2 40 20 12 250 5.0 +5V +12V 11 4.8 10 4.6 150 9 4.4 100 8 4.2 7 4.0 +12V +5V 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 45 ) 60 55 (VERTICAL) (HORIZONTAL) 50 25 -12V -10 200 60 80 100 120 140 160 180 200 INPUT VOLTAGE (V) 60Hz 220 240 260 OUTPUT RIPPLE (mVp-p) 13