TOTAL-POWER S-60

TOTAL POWER INT'L
60W Single Output Switching Power Supply
S-60
series
Features :
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 50KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT
S-60-5
S-60-12
S-60-15
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
12A
5A
4A
2.5A
CURRENT RANGE
0 ~ 12A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
RATED POWER
60W
60W
120mVp-p
60W
60W
150mVp-p
150mVp-p
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
LINE REGULATION
0.5%
LOAD REGULATION
INPUT
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD TIME
1.0%
300ms, 50ms, 80ms / 230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
73%
76%
AC CURRENT
INRUSH CURRENT(max.)
2A/115VAC
1A/230VAC
COLD START 30A/115VAC
60A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
S-60-24
800ms, 50ms, 10ms / 115VAC at full load
120 ~ 370VDC
5.75 ~ 6.75V
77%
13.8 ~ 16.2V
17.25 ~ 20.25
79%
27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012, UL1950, TUV EN60950 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
EMC
(Note 4)
OTHERS
NOTE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
DIMENSION
316.2K hrs min. MIL-HDBK-217F (25
159*97*38mm (L*W*H)
PACKING
0.51Kg; 24pcs/13.1Kg/0.7CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
S-60
60W Single Output Switching Power Supply
Mechanical Specification
Case No. 901
series
Unit:mm
3.5
7
152.5
1
3
84.5
8.2
4
5
2 -M
97
65
9.5
2
3
3 .5
4.5
24
78
159
6.5
28.5
38
M3
18
3 .5
3-
3.5
18.5
9
9
150
117
22
Terminal Pin. No Assignment
Pin No.
1
2
3
Pin No.
4
5
Assignment
AC/L
AC/N
FG
Assignment
DC OUTPUT -V
DC OUTPUT +V
Static Characteristics (24V)
OUTPUT VOLTAGE (V)
100
80
LOAD (%)
60
40
20
-10
-10
Ta=25
Vo
32
0
0
10
20
30
40
AMBIENT TEMPERATURE (
50
45
)
60
55
(VERTICAL)
(HORIZONTAL)
350
28
300
24
250
20
200
16
150
12
100
8
50
60
80
100
120
140
160
180
200
INPUT VOLTAGE (V) 60Hz
220
240
260
OUTPUT RIPPLE (mVp-p)
Output Derating