TOTAL POWER INT'L 60W Single Output Switching Power Supply S-60 series Features : Universal AC input/Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 50KHz 2 years warranty SPECIFICATION MODEL OUTPUT S-60-5 S-60-12 S-60-15 DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 12A 5A 4A 2.5A CURRENT RANGE 0 ~ 12A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A RATED POWER 60W 60W 120mVp-p 60W 60W 150mVp-p 150mVp-p 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V RIPPLE & NOISE (max.) Note.2 120mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% LOAD REGULATION INPUT 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE, HOLD TIME 1.0% 300ms, 50ms, 80ms / 230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 73% 76% AC CURRENT INRUSH CURRENT(max.) 2A/115VAC 1A/230VAC COLD START 30A/115VAC 60A/230VAC LEAKAGE CURRENT <3.5mA / 240VAC OVER LOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE S-60-24 800ms, 50ms, 10ms / 115VAC at full load 120 ~ 370VDC 5.75 ~ 6.75V 77% 13.8 ~ 16.2V 17.25 ~ 20.25 79% 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed. -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL1950, TUV EN60950 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE EMC (Note 4) OTHERS NOTE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF DIMENSION 316.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) PACKING 0.51Kg; 24pcs/13.1Kg/0.7CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. S-60 60W Single Output Switching Power Supply Mechanical Specification Case No. 901 series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2 -M 97 65 9.5 2 3 3 .5 4.5 24 78 159 6.5 28.5 38 M3 18 3 .5 3- 3.5 18.5 9 9 150 117 22 Terminal Pin. No Assignment Pin No. 1 2 3 Pin No. 4 5 Assignment AC/L AC/N FG Assignment DC OUTPUT -V DC OUTPUT +V Static Characteristics (24V) OUTPUT VOLTAGE (V) 100 80 LOAD (%) 60 40 20 -10 -10 Ta=25 Vo 32 0 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 45 ) 60 55 (VERTICAL) (HORIZONTAL) 350 28 300 24 250 20 200 16 150 12 100 8 50 60 80 100 120 140 160 180 200 INPUT VOLTAGE (V) 60Hz 220 240 260 OUTPUT RIPPLE (mVp-p) Output Derating