MEANWELL PB-120P-13CO

120W Single Output Power Supply or Battery Charger
PA / P B - 1 2 0
series
Features :
AC input range selected by switch
Built-in passive PFC function compliance to EN61000-3-2
With AC ON-OFF switch
3 poles AC inlet with fuse holder
Protections: Short circuit / Overload / Over voltage / Over temperature
Charger type can be selected (Optional)
Charger for lead-acid batteries
2 color LED loading indicator
Open frame models available (Without safety approval)
Low cost, High reliability
2 years warranty
TUV
Rheinland
Product Safety
S:Power Supply
A:Voltage detector
B:Current detector
P A
120 P
geprUfre
Sicherheit
13 C
:O.D.M. number
P:Open P.C.B.
C:With case
13:13.8V
27:27.6V
54:55.2V
P:With PFC
N:None PFC
SPECIFICATION
MODEL
OUTPUT
PA/PB-120
PA/PB-120
-27
PA/PB-120
13.8V
27.6V
55.2V
RATED CURRENT
7.2A
4.3A
2.2A
CURRENT RANGE
0 ~ 7.2A
0 ~ 4.3A
0 ~ 2.2A
RATED POWER
99.36W
118.68W
121.44W
LED INDICATED
INPUT
-13
DC VOLTAGE
PA series voltage 105% 1%
PB series load 46% 10%
: RED / 105% 1%
: GREEN / 46% 10%
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
>0.65 (with PFC series)
:GREEN
:RED
EFFICIENCY (Typ.)
73%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC
1.5A/230VAC
COLD START 25A/115VAC
LEAKAGE CURRENT
<1.5mA / 240VAC
OVERLOAD
90 ~ 110% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
-54
79%
79%
50A/230VAC
15 ~ 17V
30 ~ 35V
60 ~ 66V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
RTH2 70
10 detect on RTH2 thermistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +45
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 45
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
OTHERS
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
DIMENSION
149.6K hrs min.
PACKING
NOTE
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
MIL-HDBK-217F (25
)
PCB Type:144*90*33mm
External case type:180*96*49mm (L*W*H)
1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC)
1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. With PFC I/P range: 95~132VAC/190~264VAC.
6. For open P.C.B. WITH 17.8CFM min. Forced air.
File Name:PA,PB-120-SPEC 2008-05-06
120W Single Output Power Supply or Battery Charger
PA / P B - 1 2 0
Mechanical Specification
Case No. PS-120A
series
Unit:mm
1
2
3
115
FUSE
CASE:
Output cable length=183cm 5cm
Assignment
DC OUTPUT +V
DC OUTPUT -V
Pin No.
1
2,3
Pin No.
1
2
3
Assignment
AC/L
No Pin
AC/N
49
PCB:
AC Input Connector (CN1) : JST B3P-VH or equivalent
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
180
144
4-
134
3.
5
8
12VDC FAN Output Connector (CN4) : JST B2B-XH or equivalent
Assignment
+V
-V
JST XHP
or equivalent
ADJ.
Terminal
Mating Housing
CN4
JST SXH-001T-P0.6
or equivalent
F4 A/250V
Pin No.
1
2
CN3
+V
JST SVH-21T-P1.1
or equivalent
-V
Terminal
JST VHR
or equivalent
1 2 3 4
Mating Housing
80
Assignment
-V
+V
90
Pin No.
1,2
3,4
5
DC Output Connector (CN3) : JST B4P-VH or equivalent
LED
12
+CN5
1 2 3
SHORT FOR 115V
OPEN FOR 230V
CN1
Switch
115V
230V
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
2 max.
Assignment
Short
Open
33
115/230V selected by switch Connector (CN5) : JST B2P-VH or equivalent
Derating Curve
Charging Curve
Vout
105%
100%
100
Charging Current
Open frame series
17.8CFM air cooling
(L=15cm face HS)
80
Iout
Bat. Voltage
100%
45%
Other series
LOAD (%)
60
Red
LED COLOR
Green
T
Type A:Voltage detecter,pulse charger
40
Vout
105%
100%
Iout
Bat. Voltage
20
Charging Current
-10
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
100%
(HORIZONTAL)
LED COLOR
Red
Green
Type B:Current detecter,2 voltage section
T