MPD D219ERW

D200ERW Series
Low Cost, Miniature
2W SIP, Wide Input
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Short Circuit Protected
• Miniature SIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
• Low Low Cost!!
RoHS Compliant
Input
Parameter
Input Voltage Range
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
Min.
4.5
9.0
18.0
36.0
Typ.
5.0
12.0
24.0
48.0
Reverse Polarity Input Current
Short Circuit Input Power
Max.
9.0
18.0
36.0
72.0
1.0
1,500
Units
Max.
±3.0
±2.0
±0.5
±0.75
±1.0
100
Units
%
%
%
%
%
mV P - P
%
%/°C
VDC
A
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation , Single Output
Load Regulation , Dual Output
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Vin = Min to Max
Iout = 10% to 100%
Iout = 10% to 100%
See Note 1
Typ.
±1.0
±1.0
±0.2
±0.5
±0.5
35
120
±0.03
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Iout = 100%
Min.
1,500
1,000
Typ.
Max.
500
Units
VDC
MΩ
pF
kHz
Max.
+85
+125
Units
°C
°C
95
%
80
180
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
Conditions
Min.
Typ.
-40
+25
-50
Free Air Convection
RH, Non-condensing
Ambient
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
Case Size
Case Material
Weight
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
0.87 x 0.47 x 0.37 Inches (22.0 x 12.0 x 9.50 mm)
Non-Conductive Black Plastic (UL94-V0)
0.19 Oz (5.5g)
Reliability Specifications
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
11.0
22.0
40.0
80.0
300
1,800
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
VDC
°C
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
D201ERW
D202ERW
D203ERW
D204ERW
D205ERW
D206ERW
D207ERW
D208ERW
D209ERW
D211ERW
D212ERW
D213ERW
D214ERW
D215ERW
D216ERW
D217ERW
D218ERW
D219ERW
D221ERW
D222ERW
D223ERW
D224ERW
D225ERW
D226ERW
D227ERW
D228ERW
D229ERW
D231ERW
D232ERW
D233ERW
D234ERW
D235ERW
D236ERW
D237ERW
D238ERW
D239ERW
Input
Output
Efficiency
Voltage Current
Current
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Typ)
5
4.5 - 9.0
508
40
3.3
500.0
50.0
65
5
4.5 - 9.0
588
40
5.0
400.0
40.0
68
5
4.5 - 9.0
555
40
9.0
222.0
22.0
72
5
4.5 - 9.0
547
40
12.0
166.0
16.0
73
5
4.5 - 9.0
555
40
15.0
133.0
13.0
72
5
4.5 - 9.0
547
40
24.0
83.0
8.0
73
5
4.5 - 9.0
597
40
±5.0
±200.0
±20.0
67
5
4.5 - 9.0
555
40
±12.0
±83.0
±8.0
72
5
4.5 - 9.0
547
40
±15.0
±66.0
±7.0
73
12
9.0 - 18.0
191
20
3.3
500.0
50.0
72
12
9.0 - 18.0
216
20
5.0
400.0
40.0
77
12
9.0 - 18.0
211
20
9.0
222.0
22.0
79
12
9.0 - 18.0
206
20
12.0
166.0
16.0
81
12
9.0 - 18.0
208
20
15.0
133.0
13.0
80
12
9.0 - 18.0
208
20
24.0
83.0
8.0
80
12
9.0 - 18.0
222
20
±5.0
±200.0
±20.0
75
12
9.0 - 18.0
214
20
±12.0
±83.0
±8.0
78
12
9.0 - 18.0
214
20
±15.0
±66.0
±7.0
78
24
18.0 - 36.0
96
10
3.3
500.0
50.0
72
24
18.0 - 36.0
108
10
5.0
400.0
40.0
77
24
18.0 - 36.0
105
10
9.0
222.0
22.0
79
24
18.0 - 36.0
103
10
12.0
166.0
16.0
81
24
18.0 - 36.0
104
10
15.0
133.0
13.0
80
24
18.0 - 36.0
104
10
24.0
83.0
8.0
80
24
18.0 - 36.0
109
10
±5.0
±200.0
±20.0
76
24
18.0 - 36.0
105
10
±12.0
±83.0
±8.0
79
24
18.0 - 36.0
107
10
±15.0
±66.0
±7.0
78
48
36.0 - 72.0
48
5
3.3
500.0
50.0
71
48
36.0 - 72.0
55
5
5.0
400.0
40.0
75
48
36.0 - 72.0
53
5
9.0
222.0
22.0
79
48
36.0 - 72.0
52
5
12.0
166.0
16.0
80
48
36.0 - 72.0
53
5
15.0
133.0
13.0
79
48
36.0 - 72.0
52
5
24.0
83.0
8.0
80
48
36.0 - 72.0
55
5
±5.0
±200.0
±20.0
75
48
36.0 - 72.0
52
5
±12.0
±83.0
±8.0
80
48
36.0 - 72.0
52
5
±15.0
±66.0
±7.0
80
Notes:
1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx. 1 µF to 10 µF) be
placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual
output units.
Output Capacitor
2. These units should not be operated with a load under
Input
10% of full load. Operation at no-load may cause
Vin Capacitor
Vout 0 - 70ºC -40 - 85ºC
damage to the unit.
(Electrolitic) (Tantalum)
3. These converters are specified for operation without
external components. However, in some applications 5 VDC
100 µF
5 VDC
100 µF
47 µF
the addition of input/output capacitors will enhance 12 VDC
100 µF
9 VDC
100 µF
47 µF
stability and reduce output ripple. Recommended
24 VDC
10 µF
12 VDC
100 µF
47 µF
capacitor values are given at right.
Output ripple on single output units may be further 48 VDC
10 µF
15 VDC
100 µF
47 µF
enhanced by using the CS terminal (single output
units operated at 50% load or below should use this function). A
Output Voltage
low ESR capacitor is connected between the CS pin and the -Vout
3.3V 5V 9V 12V 15V 24V
pin (the capcitor anode connected to the -Vout pin). Recommended
capacitor values are given in the table at right. If not used, the CS CS
47 µF - 100 µF
22 µF - 47 µF
pin should be left open.
4. Dual output units may be connected to provide a 10V, 24V or 30 VDC output. To do this, connect the load across
the +Vout and -Vout outputs and float the output common.
5. The remote on/off control pin is referenced to the -Vin pin. Input current
Min
Max
to the pin should be between 5 - 10 mA with a maximum of 20 mA.
<0.6 VDC to Open Circuit
6. It is recommended that a fuse be used on the input of a power supply for On
Off
2.7 VDC
15.0 VDC
protection. See the Model Selection table above for the correct rating.
Fuse Rating
Slow-Blow
(mA)
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
700
700
700
700
350
350
350
350
350
350
350
350
350
135
135
135
135
135
135
135
135
135
Mechanical Dimensions
Derating Curve
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Pin Connections
Pin Single
Dual
1
-Vin
-Vin
2
+Vin
+Vin
3
Remote ON/OFF
5
NF
NF
NF = No Function
Pin
6
7
8
Single
+Vout
-Vout
CS
Dual
+Vout
Common
-Vout
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]