D300RW Series Single & Dual Output 3W SIP, Wide Input DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 3W Output Power • 2:1 Input Voltage Range • 1,500 VDC Isolation • Short Circuit Protected • Miniature SIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out Parameter Input Voltage Range Conditions Min. Typ. Max. 12 VDC Input 9.0 12.0 18.0 24 VDC Input 18.0 24.0 36.0 Short Circuit Input Power 1,500 Units VDC mW Output Typ. Max. Units Output Voltage Accuracy Parameter ±1.0 ±3.0 % Output Voltage Balance ±1.0 ±2.0 % Line Regulation Conditions Min. Vin = Min to Max ±0.2 ±0.5 % Load Regulation , Single Output Iout = 10% to 100% ±0.5 ±0.75 % Load Regulation , Dual Output Iout = 10% to 100% ±0.5 ±1.0 % 50 100 mV P - P ±0.03 %/°C Max. Units Ripple & Noise (20 MHz) (Note 1) Output Power Protection 120 % Temperature Coefficient Output Short Circuit Continuous (Autorecovery) General RoHS Compliant Parameter Conditions Isolation Voltage Isolation Resistance Min. 60 Seconds 1,500 500 VDC 1,000 Isolation Capacitance 100 kHz, 1V Switching Frequency Iout = 100% Typ. VDC MΩ 80 200 pF 500 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Humidity 292 Page Street Suite D Stoughton, MA 02072 USA Physical T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Reliability Specifications Typ. Max. Units -40 +25 +85 °C +125 °C 95 % -50 Cooling MicroPower Direct Min. Free Air Convection RH, Non-condensing Case Size 0.87 x 0.47 x 0.37 Inches (22.0 x 12.0 x 9.50 mm) Case Material Non-Conductive Black Plastic (UL94-V0) Weight Parameter MTBF 0.20 Oz (6.0g) Conditions Min. MIL HDBK 217F, 25°C, Gnd Benign 1.0 Conditions Min. Typ. Max. Units MHours Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Typ. Max. 12 VDC Input -0.7 22.0 24 VDC Input -0.7 40.0 1.5 mm From Case For 10 Sec All Models Units VDC 300 °C 1,800 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number D301RW D302RW D303RW D304RW D305RW D306RW D307RW D308RW D311RW D312RW D313RW D314RW D315RW D316RW D317RW D318RW Input Output Efficiency Voltage (VDC) Current (mA) Voltage Current Current (%, Typ) (VDC) (mA, Max) (mA, Min) Nominal Range Full-Load No-Load 12 9.0 - 18.0 320 22 5.0 600.0 60.0 78 12 9.0 - 18.0 316 22 9.0 333.0 33.0 79 12 9.0 - 18.0 312 22 12.0 250.0 25.0 80 12 9.0 - 18.0 312 22 15.0 200.0 20.0 80 12 9.0 - 18.0 320 22 ±5.0 ±300.0 ±30.0 78 12 9.0 - 18.0 316 22 ±9.0 ±167.0 ±17.0 79 12 9.0 - 18.0 312 22 ±12.0 ±125.0 ±13.0 80 12 9.0 - 18.0 312 22 ±15.0 ±100.0 ±10.0 80 24 18.0 - 36.0 160 10 5.0 600.0 60.0 78 24 18.0 - 36.0 158 10 9.0 333.0 33.0 79 24 18.0 - 36.0 156 10 12.0 250.0 25.0 80 24 18.0 - 36.0 154 10 15.0 200.0 20.0 81 24 18.0 - 36.0 160 10 ±5.0 ±300.0 ±30.0 78 24 18.0 - 36.0 158 10 ±9.0 ±167.0 ±17.0 79 24 18.0 - 36.0 156 8 ±12.0 ±125.0 ±13.0 80 24 18.0 - 36.0 154 8 ±15.0 ±100.0 ±10.0 81 Notes: 1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx. 1 µF to 10 µF) be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. Output Capacitor Recommended capaciInput Vin Capacitor Vout 0 - 70ºC -40 - 85ºC tor values are given in (Electrolitic) (Tantalum) the table at right. Using 100 µF 5 VDC 100 µF 47 µF simple LC filter networks 12 VDC 100 µF 47 µF on the input/output will 24 VDC 10 - 47 µF 9 VDC provide further improve12 VDC 100 µF 47 µF ment. This only requires 15 VDC 100 µF 47 µF the addition of small inductors to the input/output filter circuits. Recommended values are 4.7 µH to 120 µH for an input inductor and 2.2 µH to 10 µH for an output inductor. Output ripple on single output units may Output Voltage be further enhanced by using the CS terminal (single output units operated at 50% 5V 9V 12V 15V load or below should use this function). A CS 47 µF - 100 µF 22 µF - 47 µF low ESR capacitor is connected between the CS pin and the -Vout pin (the anode of the capacitor is connected to the -Vout pin). Recommended capacitor values are given in the table above. If not used, the CS pin should be left open. 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the +Vout and -Vout outputs and float the output common. Min Max 5. The remote on/off control pin is referenced On <0.6 VDC to Open Circuit to the -Vin pin (pin 1). Input current to the pin should be between 5 - 10 mA with a Off 2.7 VDC 15.0 VDC maximum of 20 mA. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Capacitive Load Output Max Cap Load 5.0 VDC 9.0 VDC 12.0 VDC 15.0 VDC ±5.0 VDC ±9.0 VDC ±12.0 VDC ±15.0 VDC 2,200 µF 1,000 µF 820 µF 680 µF ±560 µF ±470 µF ±330 µF ±220 µF Fuse Rating Slow-Blow (mA) 700 700 700 700 700 700 700 700 350 350 350 350 350 350 350 350 Mechanical Dimensions Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Derating Curve Pin Connections Pin Single Dual 1 -Vin -Vin 2 +Vin +Vin 3 Remote ON/OFF 5 NF NF 6 +Vout +Vout 7 -Vout Common 8 CS -Vout NF = No Function MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]