D200ERW Series Low Cost, Miniature 2W SIP, Wide Input DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input Parameter Conditions 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input • 2W Output Power • 2:1 Input Voltage Range Input Voltage Range • 1,500 VDC Isolation • Short Circuit Protected Output • Miniature SIP Case Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation , Single Output Load Regulation , Dual Output Ripple & Noise (20 MHz) Temperature Coefficient Output Short Circuit • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out • Low Low Cost!! Conditions Min. 4.5 9.0 18.0 36.0 Typ. 5.0 12.0 24.0 48.0 Max. 9.0 18.0 36.0 72.0 Units Min. Typ. ±1.0 ±1.0 ±0.2 ±0.5 ±0.5 35 Max. ±3.0 ±2.0 ±0.5 ±0.75 ±1.0 100 ±0.03 Units % % % % % mV P - P %/°C Max. Units VDC M⍀ pF kHz Vin = Min to Max Iout = 10% to 100% Iout = 10% to 100% See Note 1 VDC Continuous (Autorecovery) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Iout = 100% Min. 1,500 1,000 Typ. 80 180 500 Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Remote On/Off Parameter Unit On Unit Off Off Idle Current Conditions Min. Typ. Max. Units -40 +25 +85 °C 3.4%/ ºC from +71 ºC to +100 ºC -50 +125 °C Free Air Convection RH, Non-condensing 95 % Ambient 0.87 x 0.47 x 0.37 Inches (22.0 x 12.0 x 9.50 mm) Non-Conductive Black Plastic (UL94-V0) 0.19 Oz (5.5g) Conditions See Note 3 See Note 3 Min. Typ. Max. Units Open or High Impedance 2.7 VDC To 15 VDC 5.0 mA Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 1.0 Typ. Max. Units MHours Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. 11.0 22.0 40.0 80.0 300 Units Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C Model Selection Guide Model Number D201ERW D202ERW D203ERW D204ERW D205ERW D206ERW D207ERW D208ERW D209ERW D211ERW D212ERW D213ERW D214ERW D215ERW D216ERW D217ERW D218ERW D219ERW D221ERW D222ERW D223ERW D224ERW D225ERW D226ERW D227ERW D228ERW D229ERW D231ERW D232ERW D233ERW D234ERW D235ERW D236ERW D237ERW D238ERW D239ERW Input Voltage (VDC) Current (mA) Voltage Nominal Range Full-Load No-Load (VDC) 5 4.5 - 9.0 508 40 3.3 5 4.5 - 9.0 588 40 5.0 5 4.5 - 9.0 555 40 9.0 5 4.5 - 9.0 547 40 12.0 5 4.5 - 9.0 555 40 15.0 5 4.5 - 9.0 547 40 24.0 5 4.5 - 9.0 597 40 ±5.0 5 4.5 - 9.0 555 40 ±12.0 5 4.5 - 9.0 547 40 ±15.0 12 9.0 - 18.0 191 20 3.3 12 9.0 - 18.0 216 20 5.0 12 9.0 - 18.0 211 20 9.0 12 9.0 - 18.0 206 20 12.0 12 9.0 - 18.0 208 20 15.0 12 9.0 - 18.0 208 20 24.0 12 9.0 - 18.0 222 20 ±5.0 12 9.0 - 18.0 214 20 ±12.0 12 9.0 - 18.0 214 20 ±15.0 24 18.0 - 36.0 96 10 3.3 24 18.0 - 36.0 108 10 5.0 24 18.0 - 36.0 105 10 9.0 24 18.0 - 36.0 103 10 12.0 24 18.0 - 36.0 104 10 15.0 24 18.0 - 36.0 104 10 24.0 24 18.0 - 36.0 109 10 ±5.0 24 18.0 - 36.0 105 10 ±12.0 24 18.0 - 36.0 107 10 ±15.0 48 36.0 - 72.0 48 5 3.3 48 36.0 - 72.0 55 5 5.0 48 36.0 - 72.0 53 5 9.0 48 36.0 - 72.0 52 5 12.0 48 36.0 - 72.0 53 5 15.0 48 36.0 - 72.0 52 5 24.0 48 36.0 - 72.0 55 5 ±5.0 48 36.0 - 72.0 52 5 ±12.0 48 36.0 - 72.0 52 5 ±15.0 Output Current Current (mA, Max) (mA, Min) 500.0 400.0 222.0 166.0 133.0 83.0 ±200.0 ±83.0 ±66.0 500.0 400.0 222.0 166.0 133.0 83.0 ±200.0 ±83.0 ±66.0 500.0 400.0 222.0 166.0 133.0 83.0 ±200.0 ±83.0 ±66.0 500.0 400.0 222.0 166.0 133.0 83.0 ±200.0 ±83.0 ±66.0 Capacitive Efficiency Fuse Rating Load Slow-Blow (%, Typ) (µF, Max) (mA) 50.0 40.0 22.0 16.0 13.0 8.0 ±20.0 ±8.0 ±7.0 50.0 40.0 22.0 16.0 13.0 8.0 ±20.0 ±8.0 ±7.0 50.0 40.0 22.0 16.0 13.0 8.0 ±20.0 ±8.0 ±7.0 50.0 40.0 22.0 16.0 13.0 8.0 ±20.0 ±8.0 ±7.0 Notes: 1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx. 1 µF to 10 µF) be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 2. Operation at no-load will not damage the units, however, they may not meet all specifications. A minimum 10% load is recommended. 3. Connection to the control (remote on/off) input must be made as shown in the typical connection diagram below. This input is referenced to the -Vin pin. Input current to the pin (IC) should be between 5 - 10 mA with a maximum of 20 VC - VD - 1 mA. Exceeding 20 mA could cause damage to the unit. If not used, the pin should be left open. Grounding R1 = IC the pin could damage the unit. The value for R1 can be calculated by the formula at right. 4. These converters are specified for operation without external components (except Input Output as noted above for the control input). However, in some applications the addition of Vin Capacitor Vout Capacitor input/output components will enhance stability and reduce output ripple. Recommended capacitor values are given in the table at right. Recommended inductor 5 VDC 100 µF 5 VDC 47 µF values would be 4.7-120 µH for the input and 2.2-10 µH for the output. Output 12 VDC 100 µF 12 VDC 47 µF ripple on single output units may be further enhanced by using the CS terminal (single output units operated at 50% load or below should use this function). A low 24 VDC 10 µF 15 VDC 47 µF ESR capacitor is connected between the CS pin and the -Vout pin (the anode of the 48 VDC 10 µF capacitor is connected to the -Vout pin). Recommended capacitor values are Output Voltage given in the table at right. If not used, the CS pin should be left open. 5. It is recommended that a fuse be used on the input of a power supply for 3.3V 5V 9V 12V 15V 24V protection. See the Model Selection table above for the correct rating. CS 47 µF - 100 µF 22 µF - 47 µF 2,200 1,000 820 680 520 470 ±560 ±330 ±270 2,200 1,000 820 680 520 470 ±560 ±330 ±270 2,200 1,000 820 680 520 470 ±560 ±330 ±270 2,200 1,000 820 680 520 470 ±560 ±330 ±270 65 68 72 73 72 73 67 72 73 72 77 79 81 80 80 75 78 78 72 77 79 81 80 80 76 79 78 71 75 79 80 79 80 75 80 80 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 700 700 700 700 700 700 700 700 700 350 350 350 350 350 350 350 350 350 135 135 135 135 135 135 135 135 135 Derating Curve Typical Connection Mechanical Dimensions Pin Connections Pin Single Dual 1 -Vin -Vin 2 +Vin +Vin 3 Remote ON/OFF 5 NC NC 6 +Vout +Vout 7 -Vout Common 8 CS -Vout NC = No Connection MicroPower Direct Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]