MPD MPO-25S-48

MPO-25S Series
Si l O
Single
Output, 25W
2
Compact, Open Frame
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 25W Output Power
• Universal 90-264 AC Input
• EN 60950 Compliant
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
• Low Leakage Current
Input Frequency
Input Current
• Nine Single Output Models
Inrush Current
• Meets EN55022
• >500 kHour MTBF
• Only 4.2” x 2.4” x 1.1”
Safety Ground Leakage Current
Min.
Typ.
90
127
47
See Model Selection Guide
Cold Start, 115 VAC
20.0
Cold Start, 230 VAC
36.0
115 VAC
0.35
240 VAC
0.5
Universal
Max.
264
370
63
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Set-Up Time
Rise Time
RoHS Compliant
Conditions
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Over Temperature
Conditions
Min.
Typ.
Max.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
20
230 VAC
100
115/230 VAC
200
115 VAC
30
230 VAC
20
±0.02
Continuous (Autorecovery)
See Note 3 115
135
See Note 4 105
See Note 5
U1 >135 °C
Units
mSec
mSec
mSec
%/°C
%
%
General
Parameter
Isolation Voltage
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Isolation resistance
EMI/RFI
EMC Compliance
Switching Frequency
Conditions
Input to Output
Input to Ground
Output to Ground
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Fixed
Min.
3,000
1,500
500
Typ.
Max.
Units
VAC
100
MΩ
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
100
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-10
+25
+60
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Size
Weight
4.2 x 2.4 x 1.1 Inches (107.0 x 67.0 x 28.0 mm)
4.9 Oz (0.14 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
IEN 60950, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Model Selection Guide
Input
Current (A)
Model
Number
MPO-25S-3.3
MPO-25S-05
MPO-25S-7.5
MPO-25S-12
MPO-25S-13.5
MPO-25S-15
MPO-25S-24
MPO-25S-27
MPO-25S-48
Output
Voltage (VDC)
115 VAC
230 VAC
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.60
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
Rated
3.3
5.0
7.5
12.0
13.5
15.0
24.0
27.0
48.0
Adjust
Rated
3.14 - 3.63
4.75 - 5.5
7.13 - 8.25
11.4 - 13.2
12.8 - 14.9
14.25 - 16.5
22.8 - 26.4
25.65 - 29.7
45.6 - 52.8
Notes:
1. Output voltage tolerance includes the the effects of set point
accuracy, line regulation and load regulation.
2. Ripple and noise is measured at 20 MHz bandwidth using
a 12 inch twisted pair wire to connect to the power supply
terminals. A 0.1 µF and a 47 µF capacitor are connected in
parallel as close to the power supply terminals as possible.
3. The overvoltage protection circuit shuts down the output.
The unit must be repowered to recover.
4. Overload protection is provided by a “hiccup mode” circuit.
The unit recovers automatically when the fault condition is
removed.
5. The over temperature protection circuit shuts down the output. The unit recovers automatically when the fault condition
is removed.
6. Mounting holes M1 and M2 should be grounded for EMI
purposes.
7. It is recommended that a fuse be used on the input of a power
supply for protection. See the mechanical diagram for the
correct rating.
Output
Tolerance
(%)
Current (A)
5.0
5.0
3.3
2.1
1.9
1.7
1.0
0.9
0.5
Range
0 to 5.0
0 to 5.0
0 to 3.3
0 to 2.1
0 to 1.9
0 to 1.7
0 to 1.0
0 to 0.9
0 to 0.5
Ripple &
Noise
Efficiency
(%, Typ)
(mV p-p)
±3.0
±3.0
±3.0
±2.0
±2.0
±2.0
±2.0
±2.0
±2.0
80
80
80
100
100
100
240
240
350
66
74
76
78
78
78
79
79
79
Mechanical Dimensions
Pin Connections: CN1 (Molex 41791-03 or equiv.)
Pin
1
3
Mating
Housing
Function
Terminal
AC-Line
Molex 2139 Molex 2478
or Equiv.
AC-Neutral or Equiv.
Pin Connections: CN2 (Molex 41791-04 or equiv.)
Pin
Function
1, 2
3, 4
+Vout
-Vout
Mating
Housing
Terminal
Molex 2139 Molex 2478
or Equiv.
or Equiv.
Static Characteristics: 24V
Derating Curve
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]