NI NI5152

High-Speed Digitizers – Optimized for Automated Test
NI 5154, NI 5153, NI 5152 NEW!
•
•
•
•
•
2 GS/s maximum real-time sample rate
1 GHz, 500 MHz, and 300 MHz bandwidths
8-bit resolution
8, 64, or 256 MB memory per channel
Edge, window, hysteresis, digital,
immediate, and software triggering
• PXI and PCI versions
Calibration
• Gain, offset, triggering, and timing
self-calibration
• 2-year external calibration interval
Operating Systems
• Windows Vista/XP/2000
• LabVIEW Real-Time
Recommended Software
•
•
•
•
LabVIEW
LabWindows™/CVI
Measurement Studio for Visual Studio
LabVIEW SignalExpress
Driver Software (included)
• NI-SCOPE driver
• LabVIEW Express VIs
• NI-SCOPE Soft Front Panel
Overview
NI 515x high-speed digitizers/PC-based
oscilloscopes provide the industry’s
first gigahertz solutions optimized for
automated test. A digitizer optimized
for automated test leverages a highthroughput bus to lower test times,
provides picosecond-level synchronization
between modules, and integrates with
the entire suite of NI hardware –
including arbitrary waveform generators,
high-speed digital I/O, and other
digitizers – so you can build and
customize a complete mixed-signal
or high-channel-count test system.
Applications
Communications
xDSL
Wireless communications
Baseband I & Q
Consumer Electronics
DVD, DVD-R, and PVR
Set-top box
Gaming console
Biomedical and Scientific Research
Ultrasonic medical imaging
Mass spectrometry
Particle physics
Aerospace/Defense
RADAR, SONAR, and LIDAR
Satellite
Signal intelligence
Dual 1 GS/s, 8-Bit Input Channels
• 2 GS/s real-time sampling on 1 channel
• 1 GS/s real-time sampling on 2 channels, simultaneously sampled
• 1 GHz (NI 5154), 500 MHz (NI 5153), or 300 MHz (NI 5152) input
bandwidth with noise filters
• 20 GS/s equivalent-time sampling (ETS) for repetitive signals
• 2-year calibration interval and 0 to +55 °C operating temperature
Deep Onboard Memory
• Take advantage of 8, 64, or 256 MB of memory per channel
• Capture more than 1 million triggered waveforms in multiple record
mode with trigger rearm time as fast as 1 µs
• Stream data continuously from onboard memory to host memory or disk
Triggering, Clocking, and Synchronization
• Edge, window, hysteresis, and digital triggering with 5 ps timestamping
• Pretrigger and posttrigger acquisition in single- and
multiple-record mode
• Internal 1 GHz clock or external clock from 350 MHz to 1 GHz
• Phase lock to PXI 10 MHz reference or external reference from
1 to 20 MHz
Software
• IVI-compliant NI-SCOPE driver for NI LabVIEW, LabWindows/CVI,
Microsoft C++, and Visual Basic
• NI-SCOPE Soft Front Panel for interactive control
• More than 50 built-in measurements with NI-SCOPE
Ordering Information
NI PXI-5154 ........................................................................780319-0M1
NI PCI-5154 ........................................................................780320-0M1
NI PXI-5153 ........................................................................780317-0M1
NI PCI-5153 ........................................................................780318-0M1
NI PXI-5152 ........................................................................779772-0M1
NI PCI-5152 ........................................................................779945-0M1
1M
(memory per channel): 1 (8 MB), 2 (64 MB), 3 (256 MB)
Includes NI-SCOPE driver and NI-SCOPE Soft Front Panel
BUY NOW!
For complete product specifications, pricing, and accessory information,
call 800 813 3693 (U.S. only) or go to ni.com/digitizers/highspeed.
High-Speed Digitizers – Optimized for Automated Test
NI High-Speed Digitizers: Optimized
for Automated Test
Prior to these products, high-bandwidth digitizers and oscilloscopes have
incorporated features and functionality best suited for benchtop use. An
unaddressed area in this high-bandwidth space has been the automated
test use model, where measurement throughput and test system
footprint can dramatically affect overall cost of test.
NI high-speed digitizers are the first high-bandwidth digitizers on the
market that share three characteristics making them uniquely optimized
for automated test: high data throughput, tight synchronization between
channels, and ease of integration with other instrumentation.
Tight Synchronization between Channels
The PXI backplane offers a built-in common reference clock for
synchronization of multiple digitizers in a measurement or control
system. Each slot has a 10 MHz TTL clock, transmitted on equal-length
traces, providing picosecond-level synchronization between digitizer
modules for high-channel-count systems. For example, it is possible to
have 34 phase-synchronous 1 GS/s channels in a single PXI chassis, and
even scale to higher channel counts.
High Data Throughput
Bus bandwidth and latency, two common considerations for an automated
test system, dictate the overall speed of your measurement system.
Latency describes the amount of time it takes for an instrument to respond
to a remote command, like a measurement query. Bus bandwidth refers
primarily to the data throughput capacity of the data bus that connects the
measurement instrument with the host PC or controller.
The PXI platform – upon which NI high-speed digitizers are built –
provides high speed due to the high-bandwidth and low-latency PCI and
PCI Express buses. Both PXI and PXI Express data throughput rates are
significantly faster than that of GPIB, USB, or LAN – other popular buses
for automating test instrumentation. This translates to lower test times.
Figure 2. The PXI platform delivers picosecond-level synchronization
between instrument modules.
Ease of Integration with Other Instrumentation
Test systems typically contain many instrument types, including signal
sources, measurement devices, and switches. The PXI platform has
unparalleled breadth, with modules for analog and digital I/O, highspeed instrumentation, vision, motion, and numerous bus interfaces.
More than 1,500 PXI modules are available from the more than 70
members of the PXI Systems Alliance (PXISA). So you can not only build
a comprehensive test system in a single chassis but also synchronize
modules in that chassis to picosecond-level accuracy when using
NI modular instrumentation.
Figure 1. The PXI platform provides the best combination of high-bandwidth and
low-latency measurement throughput.
Figure 3. The PXI platform supports more than 1,500 instrument modules.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
High-Speed Digitizers – Optimized for Automated Test
Achieve Flexible Performance Using
NI Software-Defined Instrumentation
NI high-speed digitizers offer several advantages over traditional
stand-alone oscilloscopes by delivering an open architecture and
flexible software. With an NI digitizer, you can not only perform standard
oscilloscope measurements but also easily build other instruments such
as spectrum analyzers, transient recorders, and ultrasonic receivers. And
NI offers a comprehensive library in LabVIEW of prebuilt functions and
example programs geared at getting you up and running quickly.
For rapid initiation of an automated test sequence, use preconfigured
Express VIs to quickly set up your digitizer to immediately acquire data.
LabVIEW SignalExpress is an interactive environment you can use to
acquire, analyze, and log your data with no programming required.
Open Architecture: NI-SCOPE Driver and the
Application Programming Interface (API)
Using the full power of a PC-based measurement device requires the
ability to programmatically define and control its behavior. You can
programmatically control all NI digitizers using the NI-SCOPE instrument
driver, which provides:
• High-level functions for getting started quickly as well as low-level
control for accessing all the digitizer features
• More than 50 prewritten example programs that illustrate how to
access the full functionality of any NI digitizer
• Programming examples available for LabVIEW, C++, and Visual Basic
Flexible Software: Define Your Instrument
In an automated test environment, there are times when the ability to
quickly troubleshoot an issue is crucial. For those occasions, the NI-SCOPE
driver offers the measurement features and responsiveness of a
traditional benchtop oscilloscope through the NI-SCOPE Soft Front Panel
user interface. Take advantage of the more than 50 prebuilt measurement
and analysis functions included with the software.
Figure 5. With LabVIEW SignalExpress, you can quickly set up your digitizer
to immediately acquire data.
While a quick signal check is valuable at times, other circumstances
may call for custom measurements. Stand-alone instrumentation,
such as dedicated oscilloscopes and spectrum analyzers, delivers
common functions that appeal to the needs of many engineers. As
you can imagine, these standard functions do not meet every application
need, particularly in automated test applications. But with LabVIEW
and the NI-SCOPE API, the digitizer that you use as a general-purpose
oscilloscope for one application can be used as a custom instrument
for more specialized measurements.
Figure 6. Custom measurements, such as those required for mass spectrometry, are
enabled through the combination of LabVIEW and NI modular instruments.
Figure 4. The NI-SCOPE Soft Front Panel provides measurement features
and responsiveness comparable to traditional benchtop oscilloscopes.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
High-Speed Digitizers – Optimized for Automated Test
Specifications
These specifications are valid for 0 to 55 °C unless otherwise stated.
Acquisition System
Number of channels............................ 2 simultaneously sampled
Vertical resolution............................... 8 bits
Bandwidth (-3 dB)
NI 5154..................1 GHz minimum
NI 5153.............500 MHz minimum
NI 5152:
50 Ω
340 MHz, typical
300 MHz, minimum
165 MHz, typical
135 MHz, minimum
Range (Vpp)
All except 0.1
0.1
1More
1 MΩ
300 MHz, typical
260 MHz, minimum
135 MHz, typical
110 MHz, minimum
Multiple Record Acquisition
Maximum Number of Records
32,768
100,0001
100,0001
NI 5153
Typical
NI 5152
Typical
0.1 to 1 Vpp
2 to 5 Vpp
0.1 to 1 Vpp
2 to 5 Vpp
0.1 to 1 Vpp
2 to 5 Vpp
±(1.0% of Input + 1.3% of FS)
±(1.4% of Input + 1.3% of FS)
±(1.0% of Input + 1.3% of FS)
±(1.4% of Input + 1.3% of FS)
±(1.26% of Input + 1.0% of FS + 500 µV)
±(1.26% of Input + 1.0% of FS + 5 mV)
Channel-to-channel crosstalk ............. <-80 dB at 10 MHz,
<-60 dB at 100 MHz
Spectral Characteristics
Noise Filter Noise Filter
ON
OFF
NI 5154
NI 5153
ENOB
Signal-to-noise-and-distortion (SINAD) ratio, typical
ENOB
Signal-to-noise-and-distortion (SINAD) ratio, typical
ENOB
Signal-to-noise-and-distortion (SINAD) ratio, typical
7.3
45 dB
7.3
45 dB
7.3
45 dB
6.7
41 dB
6.7
41 dB
7.1
43 dB
Timebase options................................ Internal, external (PFI 0)
Internal
Internal sample clock frequency ........ 1 GS/s sampling rate with
decimation by n, 1 ≤ n ≤ 65,535
Timebase accuracy2 ............................ ±25 ppm (±0.0025%)
if phase-locked to 10 MHz
backplane clock
1
2
5
NI 5152:
2Accuracy will improve when phase-locking to a more accurate reference, such as an NI PXI-665x
timing and synchronization module, which can provide timebase accuracy down to ±50 ppb.
External
Full-Scale Input Range and Programmable Vertical Offset
50 Ω
1 MΩ
Range
Vertical Offset
Range
Vertical Offset
(Vpp)
Range (V)
(Vpp)
Range (V)
0.1
0.2
0.4
1
2
4
10
Typical
Timebase System
Full-Scale Input Range
0.5
NI 5154
NI 5152
Full-scale input ranges
NI 5154 and NI 5153:
0.2
114 kHz, 50 Ω
106 kHz, 50 Ω; 12 Hz, 1 MΩ
DC Accuracy
than 1 million in streaming configuration
Ranges (Vpp)
0.1
AC, DC
AC, DC, GND
Accuracy
Bandwidth limit filters
(software-selectable) .............................. 20 MHz noise filter
Maximum sampling rate..................... 1 GS/s (2 ch) or 2 GS/s (1 ch)
real-time sampling, 20 GS/s
equivalent-time/randominterleaved sampling
Onboard sample memory.................... 8, 64, or 256 MB per channel
(8, 64, or 256 million samples)
Memory/Channel
8 MB
64 MB
256 MB
Input coupling
NI 5154, NI 5153 ............................
NI 5152 ...........................................
AC coupling cutoff frequency (-3 dB)
NI 5154, NI 5153 ............................
NI 5152 ...........................................
±1
±1
±1
±1
±6
±5
±2
0.1
0.2
0.4
1
2
4
10
±1
±1
±1
±1
±10
±10
±10
Input impedance
NI 5154, NI 5153 ............................ 50 Ω
NI 5152 ........................................... 50 Ω and 1 MΩ || 22 pF,
software-selectable
Maximum input overload.................... 50 Ω: 7 Vrms with |peaks|≤ 10 V
1 MΩ: |peaks| ≤ 42 V (NI 5152)
External clock sources ........................ PFI 0 (SMB connector)
External clock range............................ 350 MHz to 1 GHz, variable
with decimation by n where
1 ≤ n ≤ 65,535
External reference sources ................. PXI_CLK10 (backplane connector);
PFI 0 (front panel SMB connector)
External reference range ...................... 1 to 20 MHz in 1 MHz increments;
default to 10 MHz
External clock/reference amplitude ..... Sine wave: 0.65 to 2.8 Vpp
(0 to 13 dBm)
External clock/reference impedance.... 50 Ω, AC coupled
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
4
High-Speed Digitizers – Optimized for Automated Test
Trigger System
Modes ................................................. Edge, hysteresis, window,
digital, immediate, software
Sources................................................ CH 0, CH 1, TRIG, PFI <0..1>
PXI_Trig <0..6>, PXI Star
Trigger, and Software
Slope ................................................... Rising or falling
Hysteresis............................................ Fully programmable
High-frequency reject filter................. 50 kHz software-selectable
Low-frequency reject filter ................. 50 kHz software-selectable
Sensitivity
CH 0 and CH 1
NI 5154 ....................................... 15% FS
NI 5152, NI 5153 ........................ 10% FS
TRIG
NI 5154 ....................................... 15% FS
NI 5153 ....................................... 10% FS
NI 5152 ....................................... 5% FS
Level accuracy
CH 0, CH 1 ...................................... ±5% FS up to 10 MHz
TRIG ................................................ ±1 V up to 10 MHz
Time resolution ................................... 5 ps with time-to-digital
converter enabled
Holdoff................................................. From Rearm Time up to
[(232 – 1) x Sample Clock Period]
External Trigger Channel (TRIG)
Impedance
NI 5154, NI 5153 ............................
NI 5152 ...........................................
Vertical range......................................
Coupling
NI 5154, NI 5153 ............................
NI 5152 ...........................................
2.25 kΩ
1 MΩ || 22 pF
±5 V
DC
AC, DC
Intermodule SMC Synchronization
Using NI-TClk (typical)
Skew.................................................... 500 ps, ≤5 ps after
manual adjustment
Power Requirements (typical)
NI 5154 PXI
PCI
NI 5153 PXI
PCI
NI 5152 PXI
PCI
+3.3 VDC (A) +5 VDC (A) +12 VDC (mA) -12 VDC (mA) Total Power (W)
1.7
1.8
520
200
23.25
2.3
2.3
214
0
21.66
1.7
1.8
520
200
23.25
2.3
2.3
214
0
21.66
1.1
1.9
500
210
21.65
2.5
2.4
200
0
22.65
Environment
Operating temperature ....................... 0 to +55 °C in all NI PXI
chassis except the following:
0 to +45 °C when installed in an
NI PXI-1000/B or PXI-101x
chassis (meets IEC 60068-2-1
and IEC 60068-2-2)
Storage temperature........................... -40 to +71 °C (meets IEC 600682-1 and IEC 60068-2-2)
Relative humidity ................................ 10 to 90%, noncondensing
(meets IEC 60068-2-56)
Calibration
Self-calibration.................................... Gain, offset, triggering, and
timing for all input ranges;
1 MΩ attenuator (NI 5152 only)
External calibration interval................ 2 years
Certification and Compliances
CE Mark Compliance
For detailed specifications, visit ni.com/manuals.
For certifications, marks, and DoCs, visit ni.com/certification.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
5
IN
TA
PL
AN
MA
IN
NI Services and Support
P
DE
LO
Y
EL
OP
SERVICE
NEEDS
V
DE
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our Professional Services Team is composed of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
National Instruments • [email protected]
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351664A-01*
351664A-01
2008-10107-101-D
©2008 National Instruments. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and SignalExpress
are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the
United States and other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a
business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments.