PLL PLL620

PLL620-28/-29
Low Phase Noise VCXO (for 100-200MHz Fund Xtal)
PIN CONFIGURATION
(Top View)
FEATURES
•
•
•
•
•
•
•
100MHz to 200MHz Fundamental Mode Crystal.
Output range: 100 – 200MHz (no PLL).
Low Injection Power for crystal 50uW.
Sub 0.5pS RMS phase jitter ( 12kHz to 20MHz ).
PECL (PLL620-28) or LVDS output (PLL620-29).
Supports 2.5V or 3.3V-Power Supply.
Available in 16-Pin TSSOP.
DESCRIPTION
The PLL620-28/-29 family of XO ICs is specifically
designed to work with high frequency fundamental
and third overtone crystals. They achieve very low
current into the crystal, resulting in better stability.
Their very low jitter makes them ideal for the most
demanding timing requirements.
BLOCK DIAGRAM
OE
Q
XIN
XOUT
Oscillator
Amplifier
Q
OUTPUT ENABLE LOGICAL LEVELS
Part #
PLL620-28
PLL620-28/-29
PLL620-29
OE
0 (Default)
State
Output enabled
1
0
1 (Default)
Tri-state
Tri-state
Output enabled
OE input: Logical states defined by PECL levels for PLL620-28
Logical states defined by CMOS levels for PLL620-29
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 07/08/05 Page 1
PLL620-28/-29
Low Phase Noise VCXO (for 100-200MHz Fund Xtal)
PIN DESCRIPTIONS
Name
Pin number
Type
Description
XIN
2
I
Crystal input. See Crystal Specifications on page 2.
XOUT
3
I
Crystal output. See Crystal Specifications on page 2.
OE
6
I
Output enable pin. See Output Enable Logic Levels on page 1.
GND
8, 9, 10, 14
P
Ground.
CLKT
11
O
True output PECL (PLL620-28) or LVDS (PLL620-29)
CLKC
13
O
Complementary output PECL (PLL620-28) or LVDS (PLL620-29).
DNC
4, 5, 7, 15, 16
-
DO Not connect.
VDD
1, 12
P
Power supply.
ELECTRICAL SPECIFICATIONS
1. Absolute Maximum Ratings
PARAMETERS
SYMBOL
Supply Voltage
V DD
Input Voltage, dc
Output Voltage, dc
Storage Temperature
Ambient Operating Temperature*
Junction Temperature
Lead Temperature (soldering, 10s)
VI
VO
TS
TA
TJ
MIN.
-0.5
-0.5
-65
-40
ESD Protection, Human Body Model
MAX.
UNITS
4.6
V
V DD +0.5
V DD +0.5
150
85
125
260
V
V
2
°C
°C
°C
°C
kV
Exposure of the device under conditions beyond the limits specified by Maximum Ratings for extended periods may cause permanent damage to the
device and affect product reliability. These conditions represent a stress rating only, and functional operations of the device at these or any other
conditions above the operational limits noted in this specification is not implied.
* Note: Operating Temperature is guaranteed by design for all parts (COMMERCIAL and INDUSTRIAL), but tested for COMMERCIAL grade only.
2. Crystal Specifications
PARAMETERS
SYMBOL
CONDITIONS
Built-in Load Capacitance
CL
IC only, no PCB
capacitance included.
Shunt Capacitance
Oscillation Frequency
C0
OF
Recommended ESR
RE
Fund. Or 3 rd Overtone
MIN.
TYP.
MAX.
4
100
UNITS
pF
2
200
pF
MHz
30
Ω
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 07/08/05 Page 2
PLL620-28/-29
Low Phase Noise VCXO (for 100-200MHz Fund Xtal)
3. General Electrical Specifications
PARAMETERS
Supply Current (Loaded
Outputs)
Operating Voltage
SYMBOL
I DD
CONDITIONS
MIN.
TYP.
PECL/LVDS
V DD
2.97
45
45
@ 1.25V (LVDS)
@ V DD – 1.3V (PECL)
Output Clock Duty Cycle
50
50
±50
Short Circuit Current
MAX.
UNITS
100/80
mA
3.63
55
55
V
%
mA
4. Jitter Specifications
PARAMETERS
Period jitter RMS
Period jitter peak-to-peak
Accumulated jitter RMS
Accumulated jitter peak-to-peak
Integrated jitter RMS at 155MHz
CONDITIONS
MIN.
TYP.
MAX.
2.5
At 155.52MHz, with capacitive decoupling
between VDD and GND.
ps
18.5
At 155.52MHz, with capacitive decoupling
between VDD and GND. Over 10,000
cycles.
Integrated 12 kHz to 20 MHz
UNITS
2.5
ps
24
0.3
ps
5. Phase Noise Specifications
PARAMETERS
FREQUENCY
@10Hz
@100Hz
@1kHz
@10kHz
@100kHz
UNITS
Phase Noise relative to carrier
155.52MHz
-80
-110
-125
-143
-145
dBc/Hz
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 07/08/05 Page 3
PLL620-28/-29
Low Phase Noise VCXO (for 100-200MHz Fund Xtal)
6. LVDS Electrical Characteristics
PARAMETERS
SYMBOL
Output Differential Voltage
V DD Magnitude Change
CONDITIONS
V OD
∆V OD
V OH
V OL
V OS
Output High Voltage
Output Low Voltage
Offset Voltage
Offset Magnitude Change
R L = 100 Ω
(see figure)
I OXD
Output Short Circuit Current
I OSD
TYP.
MAX.
UNITS
247
-50
355
454
50
mV
mV
1.4
1.1
1.2
3
1.6
1.375
25
V
V
V
mV
±1
±10
uA
-5.7
-8
mA
0.9
1.125
0
∆V OS
Power-off Leakage
MIN.
V out = V DD or GND
V DD = 0V
7. LVDS Switching Characteristics
PARAMETERS
SYMBOL
CONDITIONS
MIN.
TYP.
MAX.
UNITS
Differential Clock Rise Time
tr
0.2
0.7
1.0
ns
Differential Clock Fall Time
tf
R L = 100 Ω
C L = 10 pF
(see figure)
0.2
0.7
1.0
ns
LVDS Levels Test Circuit
LVDS Switching Test Circuit
OUT
OUT
CL = 10pF
50Ω
VOD
VOS
VDIFF
50Ω
RL = 100Ω
CL = 10pF
OUT
OUT
LVDS Transistion Time Waveform
OUT
0V (Differential)
OUT
80%
VDIFF
80%
0V
20%
20%
tR
tF
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 07/08/05 Page 4
PLL620-28/-29
Low Phase Noise VCXO (for 100-200MHz Fund Xtal)
8. PECL Electrical Characteristics
PARAMETERS
SYMBOL
CONDITIONS
MIN.
V OH
V OL
R L = 50 Ω to (V DD – 2V)
(see figure)
V DD – 1.025
Output High Voltage
Output Low Voltage
MAX.
UNITS
V DD – 1.620
V
V
9. PECL Switching Characteristics
PARAMETERS
SYMBOL
Clock Rise Time
Clock Fall Time
tr
tf
CONDITIONS
MIN.
@20/80% - PECL
@80/20% - PECL
PECL Levels Test Circuit
OUT
MAX.
UNITS
0.6
0.5
1.5
1.5
ns
ns
PECL Output Skew
VDD
50Ω
TYP.
OUT
2.0V
50%
50Ω
OUT
tSKEW
OUT
PECL Transistion Time Waveform
DUTY CYCLE
45 - 55%
55 - 45%
OUT
80%
50%
20%
OUT
tR
tF
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 07/08/05 Page 5
PLL620-28/-29
Low Phase Noise VCXO (for 100-200MHz Fund Xtal)
PACKAGE INFORMATION
16 PIN TSSOP ( mm )
Symbol
A
A1
B
C
D
E
H
L
e
Min.
Max.
1.20
0.05
0.15
0.19
0.30
0.09
0.20
4.90
5.10
4.30
4.50
6.40 BSC
0.45
0.75
0.65 BSC
E
H
D
A
A1
C
e
B
L
ORDERING INFORMATION
For part ordering, please contact our Sales Department:
47745 Fremont Blvd., Fremont, CA 94538, USA
Tel: (510) 492-0990 Fax: (510) 492-0991
PART NUMBER
The order number for this device is a combination of the following:
Device number, Package type and Operating temperature range
PLL620-2X X C L R
NONE= TUBE
R=TAPE AND REEL
NONE=NORMAL PACKAGE
L=GREEN PACKAGE
TEMPERATURE
C=COMMERCIAL,
I=INDUSTRIAL
PART NUMBER
PACKAGE TYPE
O=TSSOP
Part / Order Number
Marking
Package Option
Temperature
PLL620-2XOC-R
PLL620-2XOC
P620-2XOC
P620-2XOC
TSSOP -Tape and Reel
TSSOP–Tubes
0 to +70 C
0 to +70 C
PLL620-2XOCL-R
P620-2XOCL
TSSOP-Tape and ReeL (GREEN)
0 to +70 C
PLL620-2XOC
P620-2XOCL
TSSOP–Tubes (GREEN)
0 to +70 C
PhaseLink Corporation, reserves the right to make changes in its products or specifications, or both at any time without notice. The information
furnished by Phaselink is believed to be accurate and reliable. However, PhaseLink makes no guarantee or warranty concerning the accuracy of said
information and shall not be responsible for any loss or damage of whatever nature resulting from the use of, or reliance upon this product.
LIFE SUPPORT POLICY: PhaseLink’s products are not authorized for use as critical components in life support devices or systems without the
express written approval of the President of PhaseLink Corporation.
47745 Fremont Blvd., Fremont, California 94538 Tel (510) 492-0990 Fax (510) 492-0991 www.phaselink.com Rev 07/08/05 Page 6