RECTRON BAT43W

RECTRON
BAT43W
SEMICONDUCTOR
TECHNICAL SPECIFICATION
SMALL SIGNAL DIODE
VOLTAGE RANGE 30 Volts
FEATURES
* Low Forward Voltage Drop
* Fast Switching Time
* Surface Mount Package Ideally Suited for Automatic
Insertion
SOD-123
MECHANICAL DATA
Case: Molded plastic
Epoxy: UL 94V-O rate flame retardant
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.01 gram
.110(2.80)
.102(2.60)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.006(.15)
.026(.65)
.018(.45)
.067(1.70)
.059(1.50)
.152(3.85)
.140(3.55)
.003(.08)
*
*
*
*
*
.049(1.25)
.041(1.05)
Ratings at 25 o C ambient temperature unless otherwise specified.
REF .020(0.50)
Single phase, half wave, 60 Hz, resistive or inductive load.
.004(.10)
.000(.00)
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
RATINGS
V(BR)R
Reverse Breakdown Voltage
BAT43W
UNITS
30
Volts
30
Volts
Maximum Repetitive Peak Reverse Voltage
Maximum Working Peak reverse Voltage
Maximum DC Blocking Voltage
V RRM
V RWM
VR
Maximum RMS Voltage
Maximum Forward Comtinuous Current
VRMS
IFM
IFRM
21
Volts
200
500
mAmps
mAmps
Peak Forward Surge Current @<10ms
Typical Reverse Recovery Time(I F=I R=10mA,I rr =0.1X IR,R L=100Ω)
IFSM
4.0
T rr
5
Amps
nS
Typical Junction Capacitance(V R=1.0V,f=1.0MHz)
CT
PD
RθJA
10
pF
200
mW
Non-Repetitive Peak Forward Surge Current @t<1.0s
Maximum Power Dissipation
Typical Thermal Resistance
Operating and Storage Temperature Range
TSTG
500
-55 to + 125
K/W
O
C
SYMBOL
BAT43W
UNITS
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage
Maximum Instantaneous Reverse Current
@I F =2mA
@I F =15mA
@V R =25V
VF
IR
0.33
0.45
0.5
Volts
µAmps
2006-5
IFM, FORWARD CURRENT(mA)
100
80
60
40
20
TJ = 125 OC
0
0
25
50
75
100
125
150
IF, INSTANTANEOUS FORWARD CURRENT(mA)
RATING AND CHARACTERISTICS CURVES ( BAT43W )
100
TA = 125 OC
TA = 75 OC
10
TA = 25 OC
1
TA = -25 OC
0.1
0
200
400
600
800
VF, INSTANTANEOUS FORWARD VOLTAGE(mV)
Figure1 Forward Current Derating Curve
Figure2 Typical Foward Characteristics
100
1000
CT,TOTAL CAPACITANCE(pF)
IR, INSTANTANEOUS REVERSE CURRENT(µA)
O
TA, AMBIENT TEMPERATURE( C)
TA = 125 OC
100
10
TA = 75 OC
1
0.1
TJ = 25 OC
f =1.0MHz
10
TA = 25 OC
0.01
1.0
0
10
20
30
40
0
5.0
10
15
20
25
30
35
40
VR,INSTANTANEOUS REVERSE VOLTAGE(V)
VR, REVERSE VOLTAGE(V)
Figure3 Typical Reverse Characteristics
Figure4 Total Capacitance vs Reverse Voltage
RECTRON
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
RECTRON